Certificate holders

Subtype

Versati Split G1 4-6kW

Certificate Holder
Gree Electric Appliances, Inc. of Zhuhai
West Jinji Rd
519070 Qianshan, Zhuhai, Guangdong
China
Registration number
041-K004-08
Certification Body
BRE Global Limited
Subtype title
Versati Split G1 4-6kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,000 kg

Certification Date
20.01.2021
Testing basis
HP Keymark Scheme Rules Rev 08
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

GRS-CQ4.0Pd/NhH-E+SXTVD300LC/B-E
Configure model
Model name
GRS-CQ4.0Pd/NhH-E+SXTVD300LC/B-E
Application
Heating + DHW
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Medium temperature

Heat output

3.60 kW

El input

1.31 kW

COP

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

42 dB(A)

Sound power level outdoor

62 dB(A)

EN 14825

Medium temperature

ηs

128 %

Prated

5.00 kW

SCOP

3.27

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

4.02 kW

COP Tj = -7°C

2.03

Cdh Tj = -7 °C

0.99

Pdh Tj = +2°C

2.64 kW

COP Tj = +2°C

3.27

Cdh Tj = +2 °C

0.97

Pdh Tj = +7°C

2.33 kW

COP Tj = +7°C

4.30

Cdh Tj = +7 °C

0.95

Pdh Tj = 12°C

2.78 kW

COP Tj = 12°C

6.00

Cdh Tj = +12 °C

0.95

Pdh Tj = Tbiv

4.02 kW

COP Tj = Tbiv

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.38

WTOL

60 °C

Poff

25 W

PTO

25 W

PSB

25 W

PCK

25 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

1.20 kW

Annual energy consumption Qhe

3152 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

122 %

COP

2.92

Heating up time

3.14 h:min

Standby power input

52.3 W

Reference hot water temperature

51.7 °C

Mixed water at 40°C

325 l

GRS-CQ6.0Pd/NhH-E+SXTVD300LC/B-E
Configure model
Model name
GRS-CQ6.0Pd/NhH-E+SXTVD300LC/B-E
Application
Heating + DHW
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Medium temperature

Heat output

5.61 kW

El input

1.93 kW

COP

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

42 dB(A)

Sound power level outdoor

62 dB(A)

EN 14825

Medium temperature

ηs

127 %

Prated

5.00 kW

SCOP

3.27

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

4.02 kW

COP Tj = -7°C

2.03

Cdh Tj = -7 °C

0.99

Pdh Tj = +2°C

2.64 kW

COP Tj = +2°C

3.27

Cdh Tj = +2 °C

0.97

Pdh Tj = +7°C

2.40 kW

COP Tj = +7°C

4.20

Cdh Tj = +7 °C

0.96

Pdh Tj = 12°C

2.78 kW

COP Tj = 12°C

6.00

Cdh Tj = +12 °C

0.95

Pdh Tj = Tbiv

4.02 kW

COP Tj = Tbiv

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.38

WTOL

60 °C

Poff

25 W

PTO

25 W

PSB

25 W

PCK

25 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

1.20 kW

Annual energy consumption Qhe

3169 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

122 %

COP

2.92

Heating up time

3.14 h:min

Standby power input

52.3 W

Reference hot water temperature

51.7 °C

Mixed water at 40°C

325 l