1,000 kg
Heating
EN 14511-2
Medium temperature
Heat output
3.60 kW
El input
1.31 kW
COP
2.75
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Medium temperature
Sound power level indoor
42 dB(A)
Sound power level outdoor
62 dB(A)
EN 14825
Medium temperature
ηs
128 %
Prated
5.00 kW
SCOP
3.27
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
4.02 kW
COP Tj = -7°C
2.03
Cdh Tj = -7 °C
0.99
Pdh Tj = +2°C
2.64 kW
COP Tj = +2°C
3.27
Cdh Tj = +2 °C
0.97
Pdh Tj = +7°C
2.33 kW
COP Tj = +7°C
4.30
Cdh Tj = +7 °C
0.95
Pdh Tj = 12°C
2.78 kW
COP Tj = 12°C
6.00
Cdh Tj = +12 °C
0.95
Pdh Tj = Tbiv
4.02 kW
COP Tj = Tbiv
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.38
WTOL
60 °C
Poff
25 W
PTO
25 W
PSB
25 W
PCK
25 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
1.20 kW
Annual energy consumption Qhe
3152 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
122 %
COP
2.92
Heating up time
3.14 h:min
Standby power input
52.3 W
Reference hot water temperature
51.7 °C
Mixed water at 40°C
325 l
Heating
EN 14511-2
Medium temperature
Heat output
5.61 kW
El input
1.93 kW
COP
2.90
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Medium temperature
Sound power level indoor
42 dB(A)
Sound power level outdoor
62 dB(A)
EN 14825
Medium temperature
ηs
127 %
Prated
5.00 kW
SCOP
3.27
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
4.02 kW
COP Tj = -7°C
2.03
Cdh Tj = -7 °C
0.99
Pdh Tj = +2°C
2.64 kW
COP Tj = +2°C
3.27
Cdh Tj = +2 °C
0.97
Pdh Tj = +7°C
2.40 kW
COP Tj = +7°C
4.20
Cdh Tj = +7 °C
0.96
Pdh Tj = 12°C
2.78 kW
COP Tj = 12°C
6.00
Cdh Tj = +12 °C
0.95
Pdh Tj = Tbiv
4.02 kW
COP Tj = Tbiv
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.38
WTOL
60 °C
Poff
25 W
PTO
25 W
PSB
25 W
PCK
25 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
1.20 kW
Annual energy consumption Qhe
3169 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
122 %
COP
2.92
Heating up time
3.14 h:min
Standby power input
52.3 W
Reference hot water temperature
51.7 °C
Mixed water at 40°C
325 l