Certificate holders

Subtype

Thermastage Silent Combi TSC14/ TOC14RIYF

Certificate Holder
Groupe Atlantic
44 boulevard des Etats-Unis
85000 La Roche Sur Yon
France
Registration number
012-C700096 / Issue 1
Certification Body
RISE CERT
Subtype title
Thermastage Silent Combi TSC14/ TOC14RIYF
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

3,800 kg

Certification Date
22.12.2020
Testing basis
HP Keymark Scheme 2018
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Silent Combi TSC14/ TOC14RIYF
Configure model
Model name
Silent Combi TSC14/ TOC14RIYF
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.10 kW

13.46 kW

El input

3.48 kW

4.75 kW

COP

4.34

2.83

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

130 %

Prated

17.40 kW

16.00 kW

SCOP

4.18

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

15.40 kW

14.20 kW

COP Tj = -7°C

2.90

2.12

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

9.40 kW

8.60 kW

COP Tj = +2°C

4.19

3.30

Cdh Tj = +2 °C

0.960

0.980

Pdh Tj = +7°C

6.70 kW

6.40 kW

COP Tj = +7°C

5.13

4.21

Cdh Tj = +7 °C

0.930

0.970

Pdh Tj = 12°C

8.00 kW

7.60 kW

COP Tj = 12°C

6.83

6.02

Cdh Tj = +12 °C

0.920

0.970

Pdh Tj = Tbiv

15.40 kW

14.20 kW

COP Tj = Tbiv

2.90

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.70 kW

13.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.62

1.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.970

WTOL

60 °C

60 °C

Poff

16 W

16 W

PTO

96 W

43 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.70 kW

2.70 kW

Annual energy consumption Qhe

8606 kWh

9915 kWh