Certificate holders

Subtype

03. Yutaki S & S Combi 3.0HP

Certificate Holder
Johnson Controls-Hitachi AirConditioning Spain
Ronda Shimizu, 1. Pol. Ind. Can Torrella
08233 Vacarisses, Barcelona
Spain
Registration number
041-K002-03
Certification Body
BRE Global Limited
Subtype title
03. Yutaki S & S Combi 3.0HP
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,700 kg

Certification Date
n/a
Testing basis
n/a
Phase-out Date
31.10.2024
Generate PDF Export model CSV Download certificate
  • Number of models 10

Models

RAS-3WHVNP RWM-3.0NE - Heating Only Phasing out on 31.10.2024
Configure model
Model name
RAS-3WHVNP RWM-3.0NE - Heating Only
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

2.92 kW

2.08 kW

COP

4.55

2.57

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

125 %

Prated

7.00 kW

6.00 kW

SCOP

4.20

3.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.90 kW

5.10 kW

COP Tj = -7°C

2.50

1.84

Pdh Tj = +2°C

3.59 kW

3.10 kW

COP Tj = +2°C

4.40

3.20

Pdh Tj = +7°C

2.31 kW

2.00 kW

COP Tj = +7°C

5.35

4.45

Pdh Tj = 12°C

2.10 kW

2.30 kW

COP Tj = 12°C

6.15

5.96

Pdh Tj = Tbiv

5.90 kW

5.10 kW

COP Tj = Tbiv

2.50

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.40 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

1.50 kW

Annual energy consumption Qhe

3286 kWh

3724 kWh

RAS-3WHVNP RWD-3.0NWE-200S - Heating Only Phasing out on 31.10.2024
Configure model
Model name
RAS-3WHVNP RWD-3.0NWE-200S - Heating Only
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

2.92 kW

2.08 kW

COP

4.55

2.57

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

125 %

Prated

7.00 kW

6.00 kW

SCOP

4.20

3.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.90 kW

5.10 kW

COP Tj = -7°C

2.50

1.84

Pdh Tj = +2°C

3.59 kW

3.10 kW

COP Tj = +2°C

4.40

3.20

Pdh Tj = +7°C

2.31 kW

2.00 kW

COP Tj = +7°C

5.35

4.45

Pdh Tj = 12°C

2.10 kW

2.30 kW

COP Tj = 12°C

6.15

5.96

Pdh Tj = Tbiv

5.90 kW

5.10 kW

COP Tj = Tbiv

2.50

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.40 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

1.50 kW

Annual energy consumption Qhe

3286 kWh

3724 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

132 %

COP

3.30

Heating up time

1:43 h:min

Standby power input

37.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

263 l

RAS-3WHVNP RWD-3.0NWE-260S - Heating Only Phasing out on 31.10.2024
Configure model
Model name
RAS-3WHVNP RWD-3.0NWE-260S - Heating Only
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

2.92 kW

2.08 kW

COP

4.55

2.57

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

125 %

Prated

7.00 kW

6.00 kW

SCOP

4.20

3.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.90 kW

5.10 kW

COP Tj = -7°C

2.50

1.84

Pdh Tj = +2°C

3.59 kW

3.10 kW

COP Tj = +2°C

4.40

3.20

Pdh Tj = +7°C

2.31 kW

2.00 kW

COP Tj = +7°C

5.35

4.45

Pdh Tj = 12°C

2.10 kW

2.30 kW

COP Tj = 12°C

6.15

5.96

Pdh Tj = Tbiv

5.90 kW

5.10 kW

COP Tj = Tbiv

2.50

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.40 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

1.50 kW

Annual energy consumption Qhe

3286 kWh

3724 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

136 %

COP

3.40

Heating up time

2:10 h:min

Standby power input

41.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

350 l

RAS-3WHVNP RWD-3.0NWE-200S-K - UK- Heating Only Phasing out on 31.10.2024
Configure model
Model name
RAS-3WHVNP RWD-3.0NWE-200S-K - UK- Heating Only
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

2.92 kW

2.08 kW

COP

4.55

2.57

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

125 %

Prated

7.00 kW

6.00 kW

SCOP

4.20

3.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.90 kW

5.10 kW

COP Tj = -7°C

2.50

1.84

Pdh Tj = +2°C

3.59 kW

3.10 kW

COP Tj = +2°C

4.40

3.20

Pdh Tj = +7°C

2.31 kW

2.00 kW

COP Tj = +7°C

5.35

4.45

Pdh Tj = 12°C

2.10 kW

2.30 kW

COP Tj = 12°C

6.15

5.96

Pdh Tj = Tbiv

5.90 kW

5.10 kW

COP Tj = Tbiv

2.50

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.40 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

1.50 kW

Annual energy consumption Qhe

3286 kWh

3724 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

132 %

COP

3.30

Heating up time

1:43 h:min

Standby power input

37.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

263 l

RAS-3WHVNP RWD-3.0NWE-260S-K - UK- Heating Only Phasing out on 31.10.2024
Configure model
Model name
RAS-3WHVNP RWD-3.0NWE-260S-K - UK- Heating Only
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

2.92 kW

2.08 kW

COP

4.55

2.57

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

125 %

Prated

7.00 kW

6.00 kW

SCOP

4.20

3.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.90 kW

5.10 kW

COP Tj = -7°C

2.50

1.84

Pdh Tj = +2°C

3.59 kW

3.10 kW

COP Tj = +2°C

4.40

3.20

Pdh Tj = +7°C

2.31 kW

2.00 kW

COP Tj = +7°C

5.35

4.45

Pdh Tj = 12°C

2.10 kW

2.30 kW

COP Tj = 12°C

6.15

5.96

Pdh Tj = Tbiv

5.90 kW

5.10 kW

COP Tj = Tbiv

2.50

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.40 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

1.50 kW

Annual energy consumption Qhe

3286 kWh

3724 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

136 %

COP

3.40

Heating up time

2:10 h:min

Standby power input

41.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

350 l

RAS-3WHVNP RWD-3.0NWSE-260S - Solar - Heating Only Phasing out on 31.10.2024
Configure model
Model name
RAS-3WHVNP RWD-3.0NWSE-260S - Solar - Heating Only
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

2.92 kW

2.08 kW

COP

4.55

2.57

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

125 %

Prated

7.00 kW

6.00 kW

SCOP

4.20

3.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.90 kW

5.10 kW

COP Tj = -7°C

2.50

1.84

Pdh Tj = +2°C

3.59 kW

3.10 kW

COP Tj = +2°C

4.40

3.20

Pdh Tj = +7°C

2.31 kW

2.00 kW

COP Tj = +7°C

5.35

4.45

Pdh Tj = 12°C

2.10 kW

2.30 kW

COP Tj = 12°C

6.15

5.96

Pdh Tj = Tbiv

5.90 kW

5.10 kW

COP Tj = Tbiv

2.50

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.40 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

1.50 kW

Annual energy consumption Qhe

3286 kWh

3724 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

136 %

COP

3.40

Heating up time

2:10 h:min

Standby power input

41.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

350 l

RAS-3WHVNP RWM-3.0NE - with cooling kit Phasing out on 31.10.2024
Configure model
Model name
RAS-3WHVNP RWM-3.0NE - with cooling kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

2.92 kW

2.08 kW

COP

4.55

2.57

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

127 %

Prated

7.00 kW

6.00 kW

SCOP

4.25

3.25

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.90 kW

5.10 kW

COP Tj = -7°C

2.50

1.84

Pdh Tj = +2°C

3.59 kW

3.10 kW

COP Tj = +2°C

4.40

3.20

Pdh Tj = +7°C

2.31 kW

2.00 kW

COP Tj = +7°C

5.35

4.45

Pdh Tj = 12°C

2.10 kW

2.30 kW

COP Tj = 12°C

6.15

5.96

Pdh Tj = Tbiv

5.90 kW

5.10 kW

COP Tj = Tbiv

2.50

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.40 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

1.50 kW

Annual energy consumption Qhe

3242 kWh

3690 kWh

RAS-3WHVNP RWD-3.0NWE-200S - with cooling kit Phasing out on 31.10.2024
Configure model
Model name
RAS-3WHVNP RWD-3.0NWE-200S - with cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

2.92 kW

2.08 kW

COP

4.55

2.57

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

127 %

Prated

7.00 kW

6.00 kW

SCOP

4.25

3.25

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.90 kW

5.10 kW

COP Tj = -7°C

2.50

1.84

Pdh Tj = +2°C

3.59 kW

3.10 kW

COP Tj = +2°C

4.40

3.20

Pdh Tj = +7°C

2.31 kW

2.00 kW

COP Tj = +7°C

5.35

4.45

Pdh Tj = 12°C

2.10 kW

2.30 kW

COP Tj = 12°C

6.15

5.96

Pdh Tj = Tbiv

5.90 kW

5.10 kW

COP Tj = Tbiv

2.50

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.40 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

1.50 kW

Annual energy consumption Qhe

3242 kWh

3690 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

132 %

COP

3.30

Heating up time

1:43 h:min

Standby power input

37.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

263 l

RAS-3WHVNP RWD-3.0NWE-260S - with cooling kit Phasing out on 31.10.2024
Configure model
Model name
RAS-3WHVNP RWD-3.0NWE-260S - with cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

2.92 kW

2.08 kW

COP

4.55

2.57

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

127 %

Prated

7.00 kW

6.00 kW

SCOP

4.25

3.25

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.90 kW

5.10 kW

COP Tj = -7°C

2.50

1.84

Pdh Tj = +2°C

3.59 kW

3.10 kW

COP Tj = +2°C

4.40

3.20

Pdh Tj = +7°C

2.31 kW

2.00 kW

COP Tj = +7°C

5.35

4.45

Pdh Tj = 12°C

2.10 kW

2.30 kW

COP Tj = 12°C

6.15

5.96

Pdh Tj = Tbiv

5.90 kW

5.10 kW

COP Tj = Tbiv

2.50

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.40 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

1.50 kW

Annual energy consumption Qhe

3242 kWh

3690 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

136 %

COP

3.40

Heating up time

2:10 h:min

Standby power input

41.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

350 l

RAS-3WHVNP RWD-3.0NWSE-260S - Solar - with cooling kit Phasing out on 31.10.2024
Configure model
Model name
RAS-3WHVNP RWD-3.0NWSE-260S - Solar - with cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

2.92 kW

2.08 kW

COP

4.55

2.57

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

127 %

Prated

7.00 kW

6.00 kW

SCOP

4.25

3.25

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.90 kW

5.10 kW

COP Tj = -7°C

2.50

1.84

Pdh Tj = +2°C

3.59 kW

3.10 kW

COP Tj = +2°C

4.40

3.20

Pdh Tj = +7°C

2.31 kW

2.00 kW

COP Tj = +7°C

5.35

4.45

Pdh Tj = 12°C

2.10 kW

2.30 kW

COP Tj = 12°C

6.15

5.96

Pdh Tj = Tbiv

5.90 kW

5.10 kW

COP Tj = Tbiv

2.50

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.40 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.30

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

1.50 kW

Annual energy consumption Qhe

3242 kWh

3690 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

136 %

COP

3.40

Heating up time

2:10 h:min

Standby power input

41.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

350 l