2,700 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.46 kW
10.34 kW
El input
2.38 kW
3.32 kW
COP
4.80
3.12
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
153 %
Prated
11.25 kW
10.10 kW
SCOP
4.95
3.89
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.96 kW
8.93 kW
COP Tj = -7°C
2.91
2.22
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
5.84 kW
5.62 kW
COP Tj = +2°C
4.84
3.83
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
3.76 kW
3.56 kW
COP Tj = +7°C
6.79
5.38
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
3.14 kW
2.99 kW
COP Tj = 12°C
8.32
6.52
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
9.96 kW
8.93 kW
COP Tj = Tbiv
2.91
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.56 kW
8.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.66
2.01
WTOL
60 °C
60 °C
Poff
19 W
19 W
PTO
19 W
19 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.69 kW
1.41 kW
Annual energy consumption Qhe
4697 kWh
5356 kWh