1,700 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.47 kW
5.04 kW
El input
1.12 kW
1.59 kW
COP
4.90
3.17
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
135 %
Prated
6.47 kW
6.03 kW
SCOP
4.66
3.45
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.72 kW
5.34 kW
COP Tj = -7°C
2.77
2.03
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
3.54 kW
3.33 kW
COP Tj = +2°C
4.41
3.32
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.22 kW
1.98 kW
COP Tj = +7°C
6.70
4.86
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.58 kW
2.40 kW
COP Tj = 12°C
8.24
6.11
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.72 kW
5.34 kW
COP Tj = Tbiv
2.79
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.09 kW
5.36 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.76
WTOL
60 °C
60 °C
Poff
19 W
19 W
PTO
19 W
19 W
PSB
19 W
19 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.38 kW
0.67 kW
Annual energy consumption Qhe
2868 kWh
3607 kWh