Certificate holders

Subtype

CTC GSi 608

Certificate Holder
CTC AB
Box 309, Näsvägen
SE-341 26 Ljungby
Sweden
Registration number
012-C700085 / Issue 3
Certification Body
RISE CERT
Subtype title
CTC GSi 608
Driving energy
Electricity
Heat Pump Type
Brine/Water
Refrigerant
R407c
Mass of Refrigerant

2,400 kg

Certification Date
30.11.2020
Testing basis
EN 14511:2018, EN 16147:2017, EN 14825:2016, EN12102:2017
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

CTC GSi 608
Configure model
Model name
CTC GSi 608
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
No

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.08 kW

5.24 kW

El input

1.27 kW

1.78 kW

COP

4.78

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

217 %

162 %

Prated

7.00 kW

7.00 kW

SCOP

5.63

4.24

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.18 kW

4.42 kW

COP Tj = -7°C

5.52

4.01

Cdh Tj = -7 °C

0.97

0.98

Pdh Tj = +2°C

2.70 kW

2.33 kW

COP Tj = +2°C

6.11

4.59

Cdh Tj = +2 °C

0.95

0.96

Pdh Tj = +7°C

2.64 kW

2.35 kW

COP Tj = +7°C

6.14

5.15

Cdh Tj = +7 °C

0.95

0.95

Pdh Tj = 12°C

2.64 kW

2.68 kW

COP Tj = 12°C

6.14

5.92

Cdh Tj = +12 °C

0.95

0.95

Pdh Tj = Tbiv

7.32 kW

6.94 kW

COP Tj = Tbiv

4.56

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.32 kW

6.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.56

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.97

0.97

WTOL

65 °C

65 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3063 kWh

4065 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

208 %

159 %

Prated

7.00 kW

7.00 kW

SCOP

5.39

4.17

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.02 kW

6.58 kW

COP Tj = -7°C

4.75

3.02

Cdh Tj = -7 °C

0.98

0.99

Pdh Tj = +2°C

3.61 kW

4.31 kW

COP Tj = +2°C

5.68

4.71

Cdh Tj = +2 °C

0.96

0.97

Pdh Tj = +7°C

2.47 kW

2.30 kW

COP Tj = +7°C

5.97

4.46

Cdh Tj = +7 °C

0.94

0.94

Pdh Tj = 12°C

2.58 kW

2.28 kW

COP Tj = 12°C

6.05

4.86

Cdh Tj = +12 °C

0.95

0.95

Pdh Tj = Tbiv

7.32 kW

6.91 kW

COP Tj = Tbiv

4.56

2.66

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.32 kW

6.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.56

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.97

0.97

WTOL

65 °C

65 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2683 kWh

3467 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

98 %

COP

2.39

Heating up time

01:58 h:min

Standby power input

79.8 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

239 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

98 %

COP

2.39

Heating up time

01:58 h:min

Standby power input

79.8 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

239 l

CTC EcoPart i608M
Configure model
Model name
CTC EcoPart i608M
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.08 kW

5.24 kW

El input

1.27 kW

1.78 kW

COP

4.78

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

217 %

162 %

Prated

7.00 kW

7.00 kW

SCOP

5.63

4.24

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.18 kW

4.42 kW

COP Tj = -7°C

5.52

4.01

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

2.70 kW

2.33 kW

COP Tj = +2°C

6.11

4.59

Cdh Tj = +2 °C

0.950

0.950

Pdh Tj = +7°C

2.64 kW

2.35 kW

COP Tj = +7°C

6.14

5.92

Cdh Tj = +7 °C

0.950

0.950

Pdh Tj = 12°C

2.64 kW

2.68 kW

COP Tj = 12°C

6.14

5.92

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

7.32 kW

6.94 kW

COP Tj = Tbiv

4.56

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.32 kW

6.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.56

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.970

WTOL

65 °C

65 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3063 kWh

4065 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

208 %

159 %

Prated

7.00 kW

7.00 kW

SCOP

5.39

4.17

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.02 kW

6.58 kW

COP Tj = -7°C

4.75

3.02

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

3.61 kW

4.31 kW

COP Tj = +2°C

5.68

4.71

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

2.47 kW

2.30 kW

COP Tj = +7°C

5.97

4.46

Cdh Tj = +7 °C

0.940

0.940

Pdh Tj = 12°C

2.58 kW

2.28 kW

COP Tj = 12°C

6.05

4.86

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

7.32 kW

6.91 kW

COP Tj = Tbiv

4.56

2.66

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.32 kW

6.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.56

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.970

WTOL

65 °C

65 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2683 kWh

3467 kWh