Certificate holders

Subtype

02. Yutaki S & S Combi 2.5HP

Certificate Holder
Johnson Controls-Hitachi AirConditioning Spain
Ronda Shimizu, 1. Pol. Ind. Can Torrella
08233 Vacarisses, Barcelona
Spain
Registration number
041-K002-02
Certification Body
BRE Global Limited
Subtype title
02. Yutaki S & S Combi 2.5HP
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,500 kg

Certification Date
n/a
Testing basis
n/a
Phase-out Date
31.10.2024
Generate PDF Export model CSV Download certificate
  • Number of models 10

Models

RAS-2.5WHVNP RWM-2.5NE - Heating Only Phasing out on 31.10.2024
Configure model
Model name
RAS-2.5WHVNP RWM-2.5NE - Heating Only
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

6.00 kW

6.00 kW

El input

1.25 kW

2.08 kW

COP

4.80

2.89

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

130 %

Prated

6.00 kW

5.00 kW

SCOP

4.50

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.95 kW

4.42 kW

COP Tj = -7°C

2.70

1.85

Pdh Tj = +2°C

3.01 kW

2.69 kW

COP Tj = +2°C

4.60

3.45

Pdh Tj = +7°C

1.90 kW

1.84 kW

COP Tj = +7°C

6.00

4.20

Pdh Tj = 12°C

1.80 kW

2.06 kW

COP Tj = 12°C

7.20

6.90

Pdh Tj = Tbiv

4.95 kW

4.42 kW

COP Tj = Tbiv

2.70

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

1.10 kW

Annual energy consumption Qhe

2569 kWh

3114 kWh

RAS-2.5WHVNP RWD-2.5NWE-200S - Heating Only Phasing out on 31.10.2024
Configure model
Model name
RAS-2.5WHVNP RWD-2.5NWE-200S - Heating Only
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

6.00 kW

6.00 kW

El input

1.25 kW

2.08 kW

COP

4.80

2.89

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

130 %

Prated

6.00 kW

5.00 kW

SCOP

4.50

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.95 kW

4.42 kW

COP Tj = -7°C

2.70

1.85

Pdh Tj = +2°C

3.01 kW

2.69 kW

COP Tj = +2°C

4.60

3.45

Pdh Tj = +7°C

1.90 kW

1.84 kW

COP Tj = +7°C

6.00

4.20

Pdh Tj = 12°C

1.80 kW

2.06 kW

COP Tj = 12°C

7.20

6.90

Pdh Tj = Tbiv

4.95 kW

4.42 kW

COP Tj = Tbiv

2.70

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

1.10 kW

Annual energy consumption Qhe

2569 kWh

3114 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

132 %

COP

3.30

Heating up time

1:43 h:min

Standby power input

37.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

263 l

RAS-2.5WHVNP RWD-2.5NWE-260S - Heating Only Phasing out on 31.10.2024
Configure model
Model name
RAS-2.5WHVNP RWD-2.5NWE-260S - Heating Only
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

6.00 kW

6.00 kW

El input

1.25 kW

2.08 kW

COP

4.80

2.89

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

130 %

Prated

6.00 kW

5.00 kW

SCOP

4.50

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.95 kW

4.42 kW

COP Tj = -7°C

2.70

1.85

Pdh Tj = +2°C

3.01 kW

2.69 kW

COP Tj = +2°C

4.60

3.45

Pdh Tj = +7°C

1.90 kW

1.84 kW

COP Tj = +7°C

6.00

4.20

Pdh Tj = 12°C

1.80 kW

2.06 kW

COP Tj = 12°C

7.20

6.90

Pdh Tj = Tbiv

4.95 kW

4.42 kW

COP Tj = Tbiv

2.70

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

1.10 kW

Annual energy consumption Qhe

2569 kWh

3114 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

136 %

COP

3.40

Heating up time

2:10 h:min

Standby power input

41.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

350 l

RAS-2.5WHVNP RWD-2.5NWE-200S-K - UK- Heating Only Phasing out on 31.10.2024
Configure model
Model name
RAS-2.5WHVNP RWD-2.5NWE-200S-K - UK- Heating Only
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

6.00 kW

6.00 kW

El input

1.25 kW

2.08 kW

COP

4.80

2.89

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

130 %

Prated

6.00 kW

5.00 kW

SCOP

4.50

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.95 kW

4.42 kW

COP Tj = -7°C

2.70

1.85

Pdh Tj = +2°C

3.01 kW

2.69 kW

COP Tj = +2°C

4.60

3.45

Pdh Tj = +7°C

1.90 kW

1.84 kW

COP Tj = +7°C

6.00

4.20

Pdh Tj = 12°C

1.80 kW

2.06 kW

COP Tj = 12°C

7.20

6.90

Pdh Tj = Tbiv

4.95 kW

4.42 kW

COP Tj = Tbiv

2.70

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

1.10 kW

Annual energy consumption Qhe

2569 kWh

3114 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

132 %

COP

3.30

Heating up time

1:43 h:min

Standby power input

37.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

263 l

RAS-2.5WHVNP RWD-2.5NWE-260S-K - UK- Heating Only Phasing out on 31.10.2024
Configure model
Model name
RAS-2.5WHVNP RWD-2.5NWE-260S-K - UK- Heating Only
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

6.00 kW

6.00 kW

El input

1.25 kW

2.08 kW

COP

4.80

2.89

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

130 %

Prated

6.00 kW

5.00 kW

SCOP

4.50

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.95 kW

4.42 kW

COP Tj = -7°C

2.70

1.85

Pdh Tj = +2°C

3.01 kW

2.69 kW

COP Tj = +2°C

4.60

3.45

Pdh Tj = +7°C

1.90 kW

1.84 kW

COP Tj = +7°C

6.00

4.20

Pdh Tj = 12°C

1.80 kW

2.06 kW

COP Tj = 12°C

7.20

6.90

Pdh Tj = Tbiv

4.95 kW

4.42 kW

COP Tj = Tbiv

2.70

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

1.10 kW

Annual energy consumption Qhe

2569 kWh

3114 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

136 %

COP

3.40

Heating up time

2:10 h:min

Standby power input

41.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

350 l

RAS-2.5WHVNP RWD-2.5NWSE-260S - Solar - Heating Only Phasing out on 31.10.2024
Configure model
Model name
RAS-2.5WHVNP RWD-2.5NWSE-260S - Solar - Heating Only
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

6.00 kW

6.00 kW

El input

1.25 kW

2.08 kW

COP

4.80

2.89

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

130 %

Prated

6.00 kW

5.00 kW

SCOP

4.50

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.95 kW

4.42 kW

COP Tj = -7°C

2.70

1.85

Pdh Tj = +2°C

3.01 kW

2.69 kW

COP Tj = +2°C

4.60

3.45

Pdh Tj = +7°C

1.90 kW

1.84 kW

COP Tj = +7°C

6.00

4.20

Pdh Tj = 12°C

1.80 kW

2.06 kW

COP Tj = 12°C

7.20

6.90

Pdh Tj = Tbiv

4.95 kW

4.42 kW

COP Tj = Tbiv

2.70

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

1.10 kW

Annual energy consumption Qhe

2569 kWh

3114 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

136 %

COP

3.40

Heating up time

2:10 h:min

Standby power input

41.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

350 l

RAS-2.5WHVNP RWM-2.5NE - with cooling kit Phasing out on 31.10.2024
Configure model
Model name
RAS-2.5WHVNP RWM-2.5NE - with cooling kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

6.00 kW

6.00 kW

El input

1.25 kW

2.08 kW

COP

4.80

2.89

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

132 %

Prated

6.00 kW

5.00 kW

SCOP

4.58

3.38

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.95 kW

4.42 kW

COP Tj = -7°C

2.70

1.85

Pdh Tj = +2°C

3.01 kW

2.69 kW

COP Tj = +2°C

4.60

3.45

Pdh Tj = +7°C

1.90 kW

1.84 kW

COP Tj = +7°C

6.00

4.20

Pdh Tj = 12°C

1.80 kW

2.06 kW

COP Tj = 12°C

7.20

6.90

Pdh Tj = Tbiv

4.95 kW

4.42 kW

COP Tj = Tbiv

2.70

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

1.10 kW

Annual energy consumption Qhe

2525 kWh

3070 kWh

RAS-2.5WHVNP RWD-2.5NWE-200S - with cooling kit Phasing out on 31.10.2024
Configure model
Model name
RAS-2.5WHVNP RWD-2.5NWE-200S - with cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

6.00 kW

6.00 kW

El input

1.25 kW

2.08 kW

COP

4.80

2.89

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

132 %

Prated

6.00 kW

5.00 kW

SCOP

4.58

3.38

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.95 kW

4.42 kW

COP Tj = -7°C

2.70

1.85

Pdh Tj = +2°C

3.01 kW

2.69 kW

COP Tj = +2°C

4.60

3.45

Pdh Tj = +7°C

1.90 kW

1.84 kW

COP Tj = +7°C

6.00

4.20

Pdh Tj = 12°C

1.80 kW

2.06 kW

COP Tj = 12°C

7.20

6.90

Pdh Tj = Tbiv

4.95 kW

4.42 kW

COP Tj = Tbiv

2.70

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

1.10 kW

Annual energy consumption Qhe

2525 kWh

3070 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

132 %

COP

3.30

Heating up time

1:43 h:min

Standby power input

37.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

263 l

RAS-2.5WHVNP RWD-2.5NWE-260S - with cooling kit Phasing out on 31.10.2024
Configure model
Model name
RAS-2.5WHVNP RWD-2.5NWE-260S - with cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

6.00 kW

6.00 kW

El input

1.25 kW

2.08 kW

COP

4.80

2.89

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

132 %

Prated

6.00 kW

5.00 kW

SCOP

4.58

3.38

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.95 kW

4.42 kW

COP Tj = -7°C

2.70

1.85

Pdh Tj = +2°C

3.01 kW

2.69 kW

COP Tj = +2°C

4.60

3.45

Pdh Tj = +7°C

1.90 kW

1.84 kW

COP Tj = +7°C

6.00

4.20

Pdh Tj = 12°C

1.80 kW

2.06 kW

COP Tj = 12°C

7.20

6.90

Pdh Tj = Tbiv

4.95 kW

4.42 kW

COP Tj = Tbiv

2.70

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

1.10 kW

Annual energy consumption Qhe

2525 kWh

3070 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

136 %

COP

3.40

Heating up time

2:10 h:min

Standby power input

41.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

350 l

RAS-2.5WHVNP RWD-2.5NWSE-260S - Solar - with cooling kit Phasing out on 31.10.2024
Configure model
Model name
RAS-2.5WHVNP RWD-2.5NWSE-260S - Solar - with cooling kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
31.10.2024

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

6.00 kW

6.00 kW

El input

1.25 kW

2.08 kW

COP

4.80

2.89

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

37 dB(A)

37 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

132 %

Prated

6.00 kW

5.00 kW

SCOP

4.58

3.38

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.95 kW

4.42 kW

COP Tj = -7°C

2.70

1.85

Pdh Tj = +2°C

3.01 kW

2.69 kW

COP Tj = +2°C

4.60

3.45

Pdh Tj = +7°C

1.90 kW

1.84 kW

COP Tj = +7°C

6.00

4.20

Pdh Tj = 12°C

1.80 kW

2.06 kW

COP Tj = 12°C

7.20

6.90

Pdh Tj = Tbiv

4.95 kW

4.42 kW

COP Tj = Tbiv

2.70

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.50

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

0 W

0 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

1.10 kW

Annual energy consumption Qhe

2525 kWh

3070 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

136 %

COP

3.40

Heating up time

2:10 h:min

Standby power input

41.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

350 l