0,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.95 kW
2.65 kW
El input
0.66 kW
0.96 kW
COP
4.49
2.76
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
205 %
148 %
Prated
4.72 kW
3.96 kW
SCOP
5.32
3.89
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.17 kW
3.51 kW
COP Tj = -7°C
4.57
3.16
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
2.49 kW
2.27 kW
COP Tj = +2°C
5.48
3.90
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
1.64 kW
1.36 kW
COP Tj = +7°C
5.99
4.61
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
1.12 kW
1.03 kW
COP Tj = 12°C
5.99
4.74
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
4.72 kW
3.96 kW
COP Tj = Tbiv
4.22
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.72 kW
3.96 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.22
2.84
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1833 kWh
2104 kWh