Certificate holders

Subtype

TTL 5.6 ACS, TTL 7.6 ACS

Certificate Holder
tecalor GmbH
Fürstenbergerstr. 77
37603 Holzminden
Germany
Registration number
011-1W0405
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TTL 5.6 ACS, TTL 7.6 ACS
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R454C
Mass of Refrigerant

3,000 kg

Certification Date
30.11.2020
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 2

Models

TTL 5.6 ACS
Configure model
Model name
TTL 5.6 ACS
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.31 kW

2.70 kW

El input

0.61 kW

0.82 kW

COP

5.42

3.29

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

208 %

143 %

Prated

3.00 kW

3.00 kW

SCOP

5.26

3.66

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.03 kW

2.97 kW

COP Tj = +2°C

4.29

2.86

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.07 kW

2.72 kW

COP Tj = +7°C

5.52

3.61

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.69 kW

3.46 kW

COP Tj = 12°C

7.51

5.33

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

3.03 kW

2.97 kW

COP Tj = Tbiv

4.29

2.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.03 kW

2.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.29

2.86

WTOL

75 °C

75 °C

Poff

12 W

12 W

PTO

10 W

10 W

PSB

12 W

12 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

768 kWh

1085 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

151 %

126 %

Prated

8.20 kW

7.80 kW

SCOP

3.84

3.23

Tbiv

-7 °C

-7 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.94 kW

4.70 kW

COP Tj = -7°C

3.67

2.94

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

3.00 kW

2.86 kW

COP Tj = +2°C

5.03

4.30

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.21 kW

3.08 kW

COP Tj = +7°C

6.81

5.42

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.74 kW

3.63 kW

COP Tj = 12°C

8.20

6.56

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

4.94 kW

4.70 kW

COP Tj = Tbiv

3.67

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.04 kW

2.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.93

2.20

WTOL

75 °C

75 °C

Poff

12 W

12 W

PTO

10 W

10 W

PSB

12 W

12 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.13 kW

5.19 kW

Annual energy consumption Qhe

5239 kWh

5927 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.00

3.64

COP Tj = -15°C (if TOL<-20°C)

2.93

2.20

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

151 %

Prated

5.50 kW

5.60 kW

SCOP

4.70

3.85

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.86 kW

4.89 kW

COP Tj = -7°C

3.40

2.64

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

2.95 kW

3.03 kW

COP Tj = +2°C

4.58

3.80

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.16 kW

2.99 kW

COP Tj = +7°C

6.32

4.84

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.74 kW

3.57 kW

COP Tj = 12°C

8.19

6.09

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

4.68 kW

4.89 kW

COP Tj = Tbiv

3.40

2.64

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.43 kW

4.13 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.06

2.22

WTOL

75 °C

75 °C

Poff

12 W

12 W

PTO

10 W

10 W

PSB

12 W

12 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.07 kW

1.50 kW

Annual energy consumption Qhe

2415 kWh

3021 kWh

TTL 7.6 ACS
Configure model
Model name
TTL 7.6 ACS
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.31 kW

2.70 kW

El input

0.61 kW

0.82 kW

COP

5.42

3.29

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

230 %

163 %

Prated

4.30 kW

4.30 kW

SCOP

5.84

4.14

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.30 kW

4.30 kW

COP Tj = +2°C

4.30

2.93

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.10 kW

2.80 kW

COP Tj = +7°C

5.77

3.90

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.70 kW

3.49 kW

COP Tj = 12°C

7.69

5.53

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

4.30 kW

4.30 kW

COP Tj = Tbiv

4.30

2.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.30 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.30

2.93

WTOL

75 °C

75 °C

Poff

12 W

12 W

PTO

10 W

10 W

PSB

12 W

12 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

984 kWh

1388 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

151 %

128 %

Prated

11.80 kW

11.90 kW

SCOP

3.84

3.26

Tbiv

-7 °C

-7 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.15 kW

7.21 kW

COP Tj = -7°C

3.17

2.70

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

4.35 kW

4.39 kW

COP Tj = +2°C

5.24

4.31

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.24 kW

3.15 kW

COP Tj = +7°C

7.18

5.99

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.75 kW

3.66 kW

COP Tj = 12°C

8.41

6.88

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

7.15 kW

7.21 kW

COP Tj = Tbiv

3.17

2.70

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.25 kW

4.98 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.74

2.22

WTOL

75 °C

75 °C

Poff

12 W

12 W

PTO

10 W

10 W

PSB

12 W

12 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.56 kW

6.93 kW

Annual energy consumption Qhe

7574 kWh

9005 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.49

6.29

COP Tj = -15°C (if TOL<-20°C)

2.74

2.22

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

153 %

Prated

8.10 kW

8.00 kW

SCOP

4.88

3.90

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.13 kW

7.04 kW

COP Tj = -7°C

3.00

2.43

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

4.34 kW

4.28 kW

COP Tj = +2°C

4.82

3.79

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.19 kW

3.05 kW

COP Tj = +7°C

6.66

5.22

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.75 kW

3.60 kW

COP Tj = 12°C

8.40

6.33

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

7.13 kW

7.04 kW

COP Tj = Tbiv

3.00

2.43

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.86 kW

6.53 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.43

WTOL

75 °C

75 °C

Poff

12 W

12 W

PTO

10 W

10 W

PSB

12 W

12 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.20 kW

1.43 kW

Annual energy consumption Qhe

3413 kWh

4219 kWh