Certificate holders

Subtype

ecoAIR 3-12 PRO

Certificate Holder
Ecoforest Geotermia S.L.
Rúa das Pontes, 25
36350 Nigrán (Pontevedra)
Spain
Registration number
011-1W0428
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
ecoAIR 3-12 PRO
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,850 kg

Certification Date
17.11.2020
Testing basis
HP KEYMARK certification scheme rules rev. 7
Generate PDF Export model CSV
  • Number of models 2

Models

ECOAIR T 3-12 PRO
Configure model
Model name
ECOAIR T 3-12 PRO
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.30 kW

4.60 kW

El input

1.11 kW

1.60 kW

COP

4.80

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

150 %

Prated

6.30 kW

6.10 kW

SCOP

4.45

3.82

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.32 kW

6.13 kW

COP Tj = +2°C

2.62

1.90

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

5.34

3.80

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

2.57 kW

2.61 kW

COP Tj = 12°C

4.41

4.51

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

6.32 kW

6.13 kW

COP Tj = Tbiv

2.62

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.32 kW

6.13 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.62

1.90

WTOL

70 °C

70 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

8 W

8 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1890 kWh

2133 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

136 %

113 %

Prated

6.60 kW

6.60 kW

SCOP

3.47

2.89

Tbiv

-12 °C

-12 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

4.06 kW

4.05 kW

COP Tj = -7°C

3.52

2.55

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.47 kW

2.41 kW

COP Tj = +2°C

4.48

3.70

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.32 kW

2.32 kW

COP Tj = +7°C

4.50

4.46

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.54 kW

2.57 kW

COP Tj = 12°C

4.28

4.48

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

4.86 kW

4.86 kW

COP Tj = Tbiv

2.74

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.04 kW

4.98 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

70 °C

70 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

8 W

8 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.60 kW

6.60 kW

Annual energy consumption Qhe

4692 kWh

5628 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.04

4.98

COP Tj = -15°C (if TOL<-20°C)

2.64

2.04

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

154 %

125 %

Prated

6.50 kW

6.50 kW

SCOP

3.93

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.76 kW

5.76 kW

COP Tj = -7°C

2.72

2.02

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.55 kW

3.56 kW

COP Tj = +2°C

4.25

3.20

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.31 kW

2.31 kW

COP Tj = +7°C

4.53

4.24

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.52 kW

2.56 kW

COP Tj = 12°C

4.26

4.50

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

5.76 kW

5.76 kW

COP Tj = Tbiv

2.72

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.68 kW

5.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.58

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

70 °C

70 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

8 W

8 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.82 kW

0.85 kW

Annual energy consumption Qhe

3418 kWh

4190 kWh

ECOAIR 3-12 PRO
Configure model
Model name
ECOAIR 3-12 PRO
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.30 kW

4.60 kW

El input

1.11 kW

1.60 kW

COP

4.80

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

150 %

Prated

6.30 kW

6.10 kW

SCOP

4.45

3.82

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.32 kW

6.13 kW

COP Tj = +2°C

2.62

1.90

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.37 kW

4.03 kW

COP Tj = +7°C

5.34

3.80

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

2.57 kW

2.61 kW

COP Tj = 12°C

4.41

4.51

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

6.32 kW

6.13 kW

COP Tj = Tbiv

2.62

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.32 kW

6.13 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.62

1.90

WTOL

70 °C

70 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

8 W

8 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1890 kWh

2133 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

136 %

113 %

Prated

6.60 kW

6.60 kW

SCOP

3.47

2.89

Tbiv

-12 °C

-12 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

4.06 kW

4.05 kW

COP Tj = -7°C

3.52

2.55

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.47 kW

2.41 kW

COP Tj = +2°C

4.48

3.70

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.32 kW

2.32 kW

COP Tj = +7°C

4.50

4.46

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.54 kW

2.57 kW

COP Tj = 12°C

4.28

4.48

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

4.86 kW

4.86 kW

COP Tj = Tbiv

2.74

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.04 kW

4.98 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

70 °C

70 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

8 W

8 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.60 kW

6.60 kW

Annual energy consumption Qhe

4692 kWh

5628 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.04

4.98

COP Tj = -15°C (if TOL<-20°C)

2.64

2.04

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

154 %

125 %

Prated

6.50 kW

6.50 kW

SCOP

3.93

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.76 kW

5.76 kW

COP Tj = -7°C

2.72

2.02

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.55 kW

3.56 kW

COP Tj = +2°C

4.25

3.20

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.31 kW

2.31 kW

COP Tj = +7°C

4.53

4.24

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.52 kW

2.31 kW

COP Tj = 12°C

4.26

4.24

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

5.76 kW

5.76 kW

COP Tj = Tbiv

2.72

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.68 kW

5.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.58

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

70 °C

70 °C

Poff

0 W

0 W

PTO

10 W

10 W

PSB

8 W

8 W

PCK

10 W

10 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.82 kW

0.85 kW

Annual energy consumption Qhe

3418 kWh

4190 kWh