Certificate holders

Subtype

DAIKIN ALTHERMA 3 M 9KW

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Registration number
011-1W0423
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA 3 M 9KW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

3,800 kg

Certification Date
27.10.2020
Testing basis
HP KEYMARK certification scheme rules rev. 7
Generate PDF Export model CSV
  • Number of models 4

Models

EBLA09D(3)V3
Configure model
Model name
EBLA09D(3)V3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.37 kW

9.57 kW

El input

1.91 kW

3.29 kW

COP

4.91

2.91

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.79 kW

Cooling capacity

9.35

EER

3.35

EN 14825

+7°C/+12°C

Pdesignc

9.30 kW

SEER

5.62

Pdc Tj = 35°C

9.40 kW

EER Tj = 35°C

3.35

Pdc Tj = 30°C

7.00 kW

EER Tj = 30°C

4.69

Cdc Tj = 30 °C

1.0

Pdc Tj = 25°C

4.90 kW

EER Tj = 25°C

6.70

Cdc Tj = 25 °C

1.0

Pdc Tj = 20°C

5.70 kW

EER Tj = 20°C

8.22

Cdc Tj = 20 °C

1.0

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

993 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

243 %

162 %

Prated

9.00 kW

9.00 kW

SCOP

6.20

4.26

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.36

2.12

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

5.90 kW

6.20 kW

COP Tj = +7°C

5.59

3.65

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

5.20 kW

5.00 kW

COP Tj = 12°C

7.87

5.68

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.36

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.36

2.12

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1938 kWh

2820 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

135 %

Prated

9.00 kW

9.00 kW

SCOP

4.82

3.44

Tbiv

-9 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.50 kW

8.50 kW

COP Tj = -7°C

3.07

2.09

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

5.50 kW

5.00 kW

COP Tj = +2°C

4.52

3.28

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.78

4.80

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.75

6.45

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

8.70 kW

8.80 kW

COP Tj = Tbiv

2.75

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.30 kW

6.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.70

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.70 kW

2.20 kW

Annual energy consumption Qhe

3854 kWh

5404 kWh

EBLA09D(3)W1
Configure model
Model name
EBLA09D(3)W1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.37 kW

9.57 kW

El input

1.91 kW

3.29 kW

COP

4.91

2.91

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.79 kW

Cooling capacity

9.35

EER

3.35

EN 14825

+7°C/+12°C

Pdesignc

9.30 kW

SEER

5.62

Pdc Tj = 35°C

9.40 kW

EER Tj = 35°C

3.35

Pdc Tj = 30°C

7.00 kW

EER Tj = 30°C

4.69

Cdc Tj = 30 °C

1.0

Pdc Tj = 25°C

4.90 kW

EER Tj = 25°C

6.70

Cdc Tj = 25 °C

1.0

Pdc Tj = 20°C

5.70 kW

EER Tj = 20°C

8.22

Cdc Tj = 20 °C

1.0

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

993 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

243 %

162 %

Prated

9.00 kW

9.00 kW

SCOP

6.20

4.26

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.36

2.12

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

5.90 kW

6.20 kW

COP Tj = +7°C

5.59

3.65

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

5.20 kW

5.00 kW

COP Tj = 12°C

7.87

5.68

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.36

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.36

2.12

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1938 kWh

2820 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

135 %

Prated

9.00 kW

9.00 kW

SCOP

4.82

3.44

Tbiv

-9 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.50 kW

8.50 kW

COP Tj = -7°C

3.07

2.09

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

5.50 kW

5.00 kW

COP Tj = +2°C

4.52

3.28

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.78

4.80

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.75

6.45

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

8.70 kW

8.80 kW

COP Tj = Tbiv

2.75

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.30 kW

6.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.70

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.70 kW

2.20 kW

Annual energy consumption Qhe

3854 kWh

5404 kWh

EDLA09D(3)V3
Configure model
Model name
EDLA09D(3)V3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.37 kW

9.57 kW

El input

1.91 kW

3.29 kW

COP

4.91

2.91

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.79 kW

Cooling capacity

9.35

EER

3.35

EN 14825

+7°C/+12°C

Pdesignc

9.30 kW

SEER

5.62

Pdc Tj = 35°C

9.40 kW

EER Tj = 35°C

3.35

Pdc Tj = 30°C

7.00 kW

EER Tj = 30°C

4.69

Cdc Tj = 30 °C

1.0

Pdc Tj = 25°C

4.90 kW

EER Tj = 25°C

6.70

Cdc Tj = 25 °C

1.0

Pdc Tj = 20°C

5.70 kW

EER Tj = 20°C

8.22

Cdc Tj = 20 °C

1.0

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

993 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

233 %

162 %

Prated

9.00 kW

9.00 kW

SCOP

5.90

4.12

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.36

2.12

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

5.90 kW

6.20 kW

COP Tj = +7°C

5.59

3.65

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

5.20 kW

5.00 kW

COP Tj = 12°C

7.87

5.68

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.36

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.36

2.12

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2039 kWh

2921 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

133 %

Prated

9.00 kW

9.00 kW

SCOP

4.72

3.39

Tbiv

-9 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.50 kW

8.50 kW

COP Tj = -7°C

3.07

2.09

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

4.50 kW

5.00 kW

COP Tj = +2°C

4.52

3.28

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.78

4.80

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.75

6.45

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

8.70 kW

8.80 kW

COP Tj = Tbiv

2.75

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.30 kW

6.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.70

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.70 kW

2.20 kW

Annual energy consumption Qhe

3939 kWh

5488 kWh

EDLA09D(3)W1
Configure model
Model name
EDLA09D(3)W1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.37 kW

9.57 kW

El input

1.91 kW

3.29 kW

COP

4.91

2.91

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.79 kW

Cooling capacity

9.35

EER

3.35

EN 14825

+7°C/+12°C

Pdesignc

9.30 kW

SEER

5.62

Pdc Tj = 35°C

9.40 kW

EER Tj = 35°C

3.35

Pdc Tj = 30°C

7.00 kW

EER Tj = 30°C

4.69

Cdc Tj = 30 °C

1.0

Pdc Tj = 25°C

4.90 kW

EER Tj = 25°C

6.70

Cdc Tj = 25 °C

1.0

Pdc Tj = 20°C

5.70 kW

EER Tj = 20°C

8.22

Cdc Tj = 20 °C

1.0

Poff

23 W

PTO

23 W

PSB

23 W

PCK

0 W

Annual energy consumption Qce

993 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

233 %

162 %

Prated

9.00 kW

9.00 kW

SCOP

5.90

4.12

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.00 kW

9.00 kW

COP Tj = +2°C

3.36

2.12

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

5.90 kW

6.20 kW

COP Tj = +7°C

5.59

3.65

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

5.20 kW

5.00 kW

COP Tj = 12°C

7.87

5.68

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

9.00 kW

9.00 kW

COP Tj = Tbiv

3.36

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

9.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.36

2.12

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2039 kWh

2921 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

133 %

Prated

9.00 kW

9.00 kW

SCOP

4.72

3.39

Tbiv

-9 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.50 kW

8.50 kW

COP Tj = -7°C

3.07

2.09

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

4.50 kW

5.00 kW

COP Tj = +2°C

4.52

3.28

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

4.70 kW

4.40 kW

COP Tj = +7°C

6.78

4.80

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

5.50 kW

5.30 kW

COP Tj = 12°C

8.75

6.45

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

8.70 kW

8.80 kW

COP Tj = Tbiv

2.75

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.30 kW

6.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.70

WTOL

35 °C

55 °C

Poff

23 W

23 W

PTO

23 W

23 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.70 kW

2.20 kW

Annual energy consumption Qhe

3939 kWh

5488 kWh