Certificate holders

Subtype

TTL 6.5/8.5 ACS

Certificate Holder
tecalor GmbH
Fürstenbergerstr. 77
37603 Holzminden
Germany
Registration number
011-1W0118
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TTL 6.5/8.5 ACS
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

2,000 kg

Certification Date
13.10.2017
Testing basis
HP KEYMARK certification scheme rules rev. no. 6
Generate PDF Export model CSV
  • Number of models 4

Models

TTL 6.5 ACS + TSBC 200 ECO, TSBB 200 S
Configure model
Model name
TTL 6.5 ACS + TSBC 200 ECO, TSBB 200 S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.86 kW

4.31 kW

El input

1.02 kW

1.58 kW

COP

4.76

2.73

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

27 dB(A)

27 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

125 %

Prated

6.80 kW

7.55 kW

SCOP

4.50

3.21

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-7 °C

Pdh Tj = -7°C

6.02 kW

5.10 kW

COP Tj = -7°C

2.90

1.97

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

3.89 kW

4.10 kW

COP Tj = +2°C

4.35

3.25

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.50 kW

2.60 kW

COP Tj = +7°C

6.60

4.56

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.39 kW

3.30 kW

COP Tj = 12°C

6.78

5.98

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

6.02 kW

6.10 kW

COP Tj = Tbiv

2.90

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.30 kW

5.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.97

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

30 W

30 W

PSB

17 W

17 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.50 kW

7.55 kW

Annual energy consumption Qhe

3120 kWh

4865 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113 %

COP

2.70

Heating up time

01:50 h:min

Standby power input

35.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

245 l

TTL 8.5 ACS + TSBC 200 ECO, TSBB 200 S
Configure model
Model name
TTL 8.5 ACS + TSBC 200 ECO, TSBB 200 S
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.86 kW

4.31 kW

El input

1.02 kW

1.58 kW

COP

4.76

2.73

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

27 dB(A)

27 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

125 %

Prated

9.19 kW

7.55 kW

SCOP

4.50

3.21

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-7 °C

Pdh Tj = -7°C

8.13 kW

5.10 kW

COP Tj = -7°C

2.72

1.97

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.22 kW

4.10 kW

COP Tj = +2°C

4.35

3.25

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.50 kW

2.60 kW

COP Tj = +7°C

6.60

4.56

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.39 kW

3.30 kW

COP Tj = 12°C

6.78

5.98

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

8.13 kW

6.10 kW

COP Tj = Tbiv

2.72

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.92 kW

5.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.97

WTOL

60 °C

60 °C

Poff

17 W

17 W

PTO

30 W

30 W

PSB

17 W

17 W

PCK

5 W

5 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.27 kW

7.55 kW

Annual energy consumption Qhe

4218 kWh

4865 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

113 %

COP

2.70

Heating up time

01:50 h:min

Standby power input

35.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

245 l

TTL 6.5 ACS, low temperature, all climates
Configure model
Model name
TTL 6.5 ACS, low temperature, all climates
Application
Heating (low temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Heat output

4.86 kW

El input

1.02 kW

COP

4.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Sound power level outdoor

57 dB(A)

EN 14825

ηs

213 %

Prated

6.30 kW

SCOP

5.41

Tbiv

2 °C

TOL

2 °C

Pdh Tj = +2°C

6.30 kW

COP Tj = +2°C

3.60

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

4.10 kW

COP Tj = +7°C

5.25

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

3.37 kW

COP Tj = 12°C

6.61

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

6.30 kW

COP Tj = Tbiv

3.60

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.60

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

1556 kWh

Colder Climate

EN 12102-1

Sound power level outdoor

57 dB(A)

EN 14825

ηs

151 %

Prated

5.80 kW

SCOP

3.85

Tbiv

-15 °C

TOL

-20 °C

Pdh Tj = -7°C

3.51 kW

COP Tj = -7°C

3.30

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

2.28 kW

COP Tj = +2°C

4.55

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

2.79 kW

COP Tj = +7°C

5.81

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

3.39 kW

COP Tj = 12°C

6.71

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

5.80 kW

COP Tj = Tbiv

2.70

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

5.80 kW

Annual energy consumption Qhe

3713 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.80

COP Tj = -15°C (if TOL<-20°C)

2.70

Cdh Tj = -15 °C

0.90

Average Climate

EN 12102-1

Sound power level outdoor

57 dB(A)

EN 14825

ηs

177 %

Prated

6.80 kW

SCOP

4.50

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

6.02 kW

COP Tj = -7°C

2.90

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

3.89 kW

COP Tj = +2°C

4.35

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

3.50 kW

COP Tj = +7°C

6.60

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

3.39 kW

COP Tj = 12°C

6.78

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

6.02 kW

COP Tj = Tbiv

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.50 kW

Annual energy consumption Qhe

3120 kWh

TTL 8.5 ACS, low temperature, all climates
Configure model
Model name
TTL 8.5 ACS, low temperature, all climates
Application
Heating (low temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Heat output

4.86 kW

El input

1.02 kW

COP

4.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Sound power level outdoor

57 dB(A)

EN 14825

ηs

215 %

Prated

7.60 kW

SCOP

5.44

Tbiv

2 °C

TOL

2 °C

Pdh Tj = +2°C

7.60 kW

COP Tj = +2°C

3.44

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

4.89 kW

COP Tj = +7°C

5.15

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

3.37 kW

COP Tj = 12°C

6.61

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

7.60 kW

COP Tj = Tbiv

3.44

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.44

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

1867 kWh

Colder Climate

EN 12102-1

Sound power level outdoor

57 dB(A)

EN 14825

ηs

147 %

Prated

8.70 kW

SCOP

3.75

Tbiv

-15 °C

TOL

-20 °C

Pdh Tj = -7°C

5.27 kW

COP Tj = -7°C

3.17

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

3.21 kW

COP Tj = +2°C

4.46

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

2.79 kW

COP Tj = +7°C

5.81

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

3.39 kW

COP Tj = 12°C

6.71

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

7.10 kW

COP Tj = Tbiv

2.54

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.19

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

8.70 kW

Annual energy consumption Qhe

5722 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.10

COP Tj = -15°C (if TOL<-20°C)

2.54

Cdh Tj = -15 °C

0.90

Average Climate

EN 12102-1

Sound power level outdoor

57 dB(A)

EN 14825

ηs

177 %

Prated

9.19 kW

SCOP

4.50

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

8.13 kW

COP Tj = -7°C

2.72

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

5.22 kW

COP Tj = +2°C

4.35

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

3.50 kW

COP Tj = +7°C

6.60

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

3.39 kW

COP Tj = 12°C

6.78

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

8.13 kW

COP Tj = Tbiv

2.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.92 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

WTOL

60 °C

Poff

17 W

PTO

30 W

PSB

17 W

PCK

5 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

1.27 kW

Annual energy consumption Qhe

4218 kWh