Certificate holders

Subtype

CALIDO1 300

Certificate Holder
Advantix S.p.A.
Via San Giuseppe Lavoratore, 24
37040 Arcole Verona
Italy
Registration number
ICIM-PDC-000091
Certification Body
ICIM S.p.A.
Subtype title
CALIDO1 300
Driving energy
Electricity
Heat Pump Type
Heat Pump for Domestic Hot Water (DHW)
Refrigerant
R134a
Mass of Refrigerant

0,920 kg

Certification Date
21.12.2020
Testing basis
V8
Generate PDF Export model CSV Download certificate
  • Number of models 3

Models

CALIDO1 300
Configure model
Model name
CALIDO1 300
Units
Indoor
Climate zone (for heating)
n/a
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Average Climate

EN 12102-2

Sound power level indoor

58 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

118 %

COP

2.85

Heating up time

9:53 h:min

Standby power input

40.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

390 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed

CALIDO1 300-S
Configure model
Model name
CALIDO1 300-S
Units
Indoor
Climate zone (for heating)
n/a
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Average Climate

EN 12102-2

Sound power level indoor

58 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

118 %

COP

2.85

Heating up time

9:53 h:min

Standby power input

40.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

390 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed

CALIDO1 300-D
Configure model
Model name
CALIDO1 300-D
Units
Indoor
Climate zone (for heating)
n/a
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Average Climate

EN 12102-2

Sound power level indoor

58 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

118 %

COP

2.85

Heating up time

9:53 h:min

Standby power input

40.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

390 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed