Certificate holders

Subtype

TERRA 6 HPLB

Certificate Holder
Ochsner Wärmepumpen GmbH
Krackowizerstraße 4
4020 Linz
Austria
Registration number
011-1W0415
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TERRA 6 HPLB
Driving energy
Electricity
Heat Pump Type
Brine/Water
Refrigerant
R410A
Mass of Refrigerant

1,400 kg

Certification Date
30.09.2020
Testing basis
HP KEYMARK certification scheme rules rev. 7
Generate PDF Export model CSV
  • Number of models 2

Models

TERRA 6 HPLB, AVERAGE CLIMATE
Configure model
Model name
TERRA 6 HPLB, AVERAGE CLIMATE
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.89 kW

5.26 kW

El input

1.23 kW

1.80 kW

COP

4.80

2.92

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

201 %

137 %

Prated

6.00 kW

5.00 kW

SCOP

5.22

3.63

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.90 kW

5.30 kW

COP Tj = -7°C

4.84

3.05

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

6.00 kW

5.50 kW

COP Tj = +2°C

5.16

3.58

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

6.00 kW

5.70 kW

COP Tj = +7°C

5.48

3.98

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

6.10 kW

5.80 kW

COP Tj = 12°C

5.84

4.45

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

5.90 kW

5.30 kW

COP Tj = Tbiv

4.78

2.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.90 kW

5.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.78

2.92

WTOL

60 °C

60 °C

Poff

0 W

0 W

PTO

55 W

55 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2326 kWh

2990 kWh

TERRA 6 HPLB, low temperature, all climates
Configure model
Model name
TERRA 6 HPLB, low temperature, all climates
Application
Heating (low temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Heat output

5.89 kW

El input

1.23 kW

COP

4.80

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Sound power level indoor

46 dB(A)

EN 14825

ηs

199 %

Prated

6.00 kW

SCOP

4.90

Tbiv

2 °C

TOL

2 °C

Pdh Tj = +2°C

5.90 kW

COP Tj = +2°C

4.78

Cdh Tj = +2 °C

 

Pdh Tj = +7°C

5.90 kW

COP Tj = +7°C

5.09

Cdh Tj = +7 °C

 

Pdh Tj = 12°C

6.00 kW

COP Tj = 12°C

5.60

Cdh Tj = +12 °C

 

Pdh Tj = Tbiv

5.90 kW

COP Tj = Tbiv

4.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.78

WTOL

60 °C

Poff

0 W

PTO

55 W

PSB

10 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

1517 kWh

Colder Climate

EN 12102-1

Sound power level indoor

46 dB(A)

EN 14825

ηs

207 %

Prated

7.00 kW

SCOP

5.11

Tbiv

-15 °C

TOL

-22 °C

Pdh Tj = -7°C

6.00 kW

COP Tj = -7°C

5.33

Cdh Tj = -7 °C

 

Pdh Tj = +2°C

6.00 kW

COP Tj = +2°C

5.58

Cdh Tj = +2 °C

 

Pdh Tj = +7°C

6.10 kW

COP Tj = +7°C

5.79

Cdh Tj = +7 °C

 

Pdh Tj = 12°C

6.10 kW

COP Tj = 12°C

5.52

Cdh Tj = +12 °C

 

Pdh Tj = Tbiv

6.00 kW

COP Tj = Tbiv

5.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.22

WTOL

60 °C

Poff

0 W

PTO

55 W

PSB

10 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

1.44 kW

Annual energy consumption Qhe

3362 kWh

Average Climate

EN 12102-1

Sound power level indoor

46 dB(A)

EN 14825

ηs

201 %

Prated

6.00 kW

SCOP

5.22

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

5.90 kW

COP Tj = -7°C

4.84

Cdh Tj = -7 °C

 

Pdh Tj = +2°C

6.00 kW

COP Tj = +2°C

5.16

Cdh Tj = +2 °C

 

Pdh Tj = +7°C

6.00 kW

COP Tj = +7°C

5.48

Cdh Tj = +7 °C

 

Pdh Tj = 12°C

6.10 kW

COP Tj = 12°C

5.84

Cdh Tj = +12 °C

 

Pdh Tj = Tbiv

5.90 kW

COP Tj = Tbiv

4.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.78

WTOL

60 °C

Poff

0 W

PTO

55 W

PSB

10 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

2326 kWh