Certificate holders

Subtype

TERRA 14 HPLA

Certificate Holder
Ochsner Wärmepumpen GmbH
Krackowizerstraße 4
4020 Linz
Austria
Registration number
011-1W0420
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TERRA 14 HPLA
Driving energy
Electricity
Heat Pump Type
Brine/Water
Refrigerant
R410A
Mass of Refrigerant

2,300 kg

Certification Date
30.09.2020
Testing basis
HP KEYMARK certification scheme rules rev. 7
Generate PDF Export model CSV
  • Number of models 2

Models

TERRA 14 HPLA, AVERAGAE CLIMATE
Configure model
Model name
TERRA 14 HPLA, AVERAGAE CLIMATE
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

13.21 kW

12.00 kW

El input

2.74 kW

3.93 kW

COP

4.82

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

142 %

Prated

13.00 kW

12.00 kW

SCOP

5.26

3.75

Tbiv

2 °C

-10 °C

TOL

-20 °C

-10 °C

Pdh Tj = -7°C

12.00 kW

12.10 kW

COP Tj = -7°C

3.05

3.18

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

12.00 kW

12.50 kW

COP Tj = +2°C

3.05

3.69

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

12.40 kW

12.80 kW

COP Tj = +7°C

3.45

4.08

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

12.90 kW

13.10 kW

COP Tj = 12°C

4.23

4.54

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

13.20 kW

12.00 kW

COP Tj = Tbiv

4.84

3.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

12.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.05

3.05

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

84 W

84 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5186 kWh

6603 kWh

TERRA 14 HPLA, low temperature, all climates
Configure model
Model name
TERRA 14 HPLA, low temperature, all climates
Application
Heating (low temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

13.21 kW

El input

2.74 kW

COP

4.82

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Sound power level indoor

50 dB(A)

EN 14825

ηs

202 %

Prated

13.00 kW

SCOP

5.25

Tbiv

2 °C

TOL

2 °C

Pdh Tj = +2°C

13.20 kW

COP Tj = +2°C

4.84

Cdh Tj = +2 °C

 

Pdh Tj = +7°C

13.30 kW

COP Tj = +7°C

5.13

Cdh Tj = +7 °C

 

Pdh Tj = 12°C

13.50 kW

COP Tj = 12°C

5.61

Cdh Tj = +12 °C

 

Pdh Tj = Tbiv

13.20 kW

COP Tj = Tbiv

4.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.84

WTOL

65 °C

Poff

0 W

PTO

84 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

3361 kWh

Colder Climate

EN 12102-1

Sound power level indoor

50 dB(A)

EN 14825

ηs

208 %

Prated

16.00 kW

SCOP

5.39

Tbiv

-15 °C

TOL

-22 °C

Pdh Tj = -7°C

13.40 kW

COP Tj = -7°C

5.35

Cdh Tj = -7 °C

 

Pdh Tj = +2°C

13.50 kW

COP Tj = +2°C

5.59

Cdh Tj = +2 °C

 

Pdh Tj = +7°C

13.60 kW

COP Tj = +7°C

5.78

Cdh Tj = +7 °C

 

Pdh Tj = 12°C

13.60 kW

COP Tj = 12°C

5.82

Cdh Tj = +12 °C

 

Pdh Tj = Tbiv

13.40 kW

COP Tj = Tbiv

5.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.25

WTOL

65 °C

Poff

0 W

PTO

84 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

3.21 kW

Annual energy consumption Qhe

7507 kWh

Average Climate

EN 12102-1

Sound power level indoor

50 dB(A)

EN 14825

ηs

203 %

Prated

13.00 kW

SCOP

5.26

Tbiv

2 °C

TOL

-20 °C

Pdh Tj = -7°C

12.00 kW

COP Tj = -7°C

3.05

Cdh Tj = -7 °C

 

Pdh Tj = +2°C

12.00 kW

COP Tj = +2°C

3.05

Cdh Tj = +2 °C

 

Pdh Tj = +7°C

12.40 kW

COP Tj = +7°C

3.45

Cdh Tj = +7 °C

 

Pdh Tj = 12°C

12.90 kW

COP Tj = 12°C

4.23

Cdh Tj = +12 °C

 

Pdh Tj = Tbiv

13.20 kW

COP Tj = Tbiv

4.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.05

WTOL

65 °C

Poff

0 W

PTO

84 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

5186 kWh