Certificate holders

Subtype

TTF 12.6, TTF 15.6

Certificate Holder
tecalor GmbH
Fürstenbergerstr. 77
37603 Holzminden
Germany
Registration number
011-1W0397
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TTF 12.6, TTF 15.6
Driving energy
Electricity
Heat Pump Type
Brine/Water
Refrigerant
R454C
Mass of Refrigerant

3,100 kg

Certification Date
08.09.2020
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 2

Models

TTF 12.6 (cool), TTC 12.6 (cool)
Configure model
Model name
TTF 12.6 (cool), TTC 12.6 (cool)
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.19 kW

4.20 kW

El input

0.84 kW

1.34 kW

COP

5.01

3.13

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

214 %

168 %

Prated

12.03 kW

11.99 kW

SCOP

5.55

4.39

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.03 kW

11.99 kW

COP Tj = +2°C

4.53

3.29

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

7.71 kW

7.69 kW

COP Tj = +7°C

5.51

4.12

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.41 kW

3.41 kW

COP Tj = 12°C

6.14

5.10

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

12.03 kW

11.99 kW

COP Tj = Tbiv

4.53

3.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.03 kW

11.99 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.53

3.29

WTOL

75 °C

75 °C

Poff

19 W

19 W

PTO

19 W

19 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2896 kWh

3650 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

224 %

174 %

Prated

12.03 kW

11.99 kW

SCOP

5.80

4.56

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.26 kW

7.24 kW

COP Tj = -7°C

5.69

4.31

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

4.41 kW

4.40 kW

COP Tj = +2°C

6.16

4.91

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

2.82 kW

2.82 kW

COP Tj = +7°C

6.19

5.16

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

2.29 kW

2.23 kW

COP Tj = 12°C

6.12

5.40

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

12.03 kW

11.99 kW

COP Tj = Tbiv

4.53

3.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.03 kW

11.99 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.53

3.29

WTOL

75 °C

75 °C

Poff

19 W

19 W

PTO

19 W

19 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5108 kWh

6485 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

216 %

169 %

Prated

12.03 kW

11.99 kW

SCOP

5.59

4.42

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.61 kW

10.59 kW

COP Tj = -7°C

4.81

3.55

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

6.45 kW

6.44 kW

COP Tj = +2°C

5.72

4.49

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.14 kW

4.13 kW

COP Tj = +7°C

6.12

4.99

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

2.30 kW

2.21 kW

COP Tj = 12°C

6.29

5.25

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

12.03 kW

11.99 kW

COP Tj = Tbiv

4.53

3.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.03 kW

11.99 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.53

3.29

WTOL

75 °C

75 °C

Poff

19 W

19 W

PTO

19 W

19 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4445 kWh

5607 kWh

TTF 15.6 (cool), TTC 15.6 (cool)
Configure model
Model name
TTF 15.6 (cool), TTC 15.6 (cool)
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.18 kW

4.72 kW

El input

1.07 kW

1.48 kW

COP

4.86

3.18

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

208 %

167 %

Prated

14.46 kW

13.77 kW

SCOP

5.41

4.37

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.46 kW

13.77 kW

COP Tj = +2°C

4.30

3.26

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

9.27 kW

8.83 kW

COP Tj = +7°C

5.13

3.99

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.11 kW

3.92 kW

COP Tj = 12°C

6.17

5.16

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

14.46 kW

13.77 kW

COP Tj = Tbiv

4.30

3.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.46 kW

13.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.30

3.26

WTOL

75 °C

75 °C

Poff

19 W

19 W

PTO

19 W

19 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3573 kWh

4211 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

218 %

174 %

Prated

14.46 kW

13.77 kW

SCOP

5.66

4.56

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.73 kW

8.32 kW

COP Tj = -7°C

5.32

4.24

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.30 kW

5.05 kW

COP Tj = +2°C

6.15

4.94

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.40 kW

3.24 kW

COP Tj = +7°C

6.27

5.24

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

2.29 kW

2.23 kW

COP Tj = 12°C

6.12

5.44

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

14.46 kW

13.77 kW

COP Tj = Tbiv

4.30

3.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.46 kW

13.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.30

3.26

WTOL

75 °C

75 °C

Poff

19 W

19 W

PTO

19 W

19 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6298 kWh

7451 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

168 %

Prated

14.46 kW

13.77 kW

SCOP

5.44

4.39

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.77 kW

12.16 kW

COP Tj = -7°C

4.46

3.40

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

7.76 kW

7.40 kW

COP Tj = +2°C

5.51

4.44

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.98 kW

4.75 kW

COP Tj = +7°C

6.13

5.03

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

2.29 kW

2.22 kW

COP Tj = 12°C

6.18

5.31

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

14.46 kW

13.77 kW

COP Tj = Tbiv

4.30

3.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.46 kW

13.77 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.30

3.26

WTOL

75 °C

75 °C

Poff

19 W

19 W

PTO

19 W

19 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5489 kWh

6476 kWh