Certificate holders

Subtype

TERRA 8 HPLB

Certificate Holder
Ochsner Wärmepumpen GmbH
Krackowizerstraße 4
4020 Linz
Austria
Registration number
011-1W0417
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TERRA 8 HPLB
Driving energy
Electricity
Heat Pump Type
Brine/Water
Refrigerant
R410A
Mass of Refrigerant

1,900 kg

Certification Date
30.09.2020
Testing basis
HP KEYMARK certification scheme rules rev. 7
Generate PDF Export model CSV
  • Number of models 2

Models

TERRA 8 HPLB, low temperature, all climates
Configure model
Model name
TERRA 8 HPLB, low temperature, all climates
Application
Heating (low temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Heat output

7.60 kW

El input

1.60 kW

COP

4.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Sound power level indoor

50 dB(A)

EN 14825

ηs

204 %

Prated

8.00 kW

SCOP

5.01

Tbiv

2 °C

TOL

2 °C

Pdh Tj = +2°C

7.60 kW

COP Tj = +2°C

4.76

Cdh Tj = +2 °C

 

Pdh Tj = +7°C

7.70 kW

COP Tj = +7°C

5.13

Cdh Tj = +7 °C

 

Pdh Tj = 12°C

7.80 kW

COP Tj = 12°C

5.77

Cdh Tj = +12 °C

 

Pdh Tj = Tbiv

7.60 kW

COP Tj = Tbiv

4.76

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.76

WTOL

60 °C

Poff

0 W

PTO

55 W

PSB

10 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

1918 kWh

Colder Climate

EN 12102-1

Sound power level indoor

50 dB(A)

EN 14825

ηs

212 %

Prated

9.00 kW

SCOP

5.24

Tbiv

-15 °C

TOL

-22 °C

Pdh Tj = -7°C

7.70 kW

COP Tj = -7°C

5.42

Cdh Tj = -7 °C

 

Pdh Tj = +2°C

7.80 kW

COP Tj = +2°C

5.74

Cdh Tj = +2 °C

 

Pdh Tj = +7°C

7.80 kW

COP Tj = +7°C

6.01

Cdh Tj = +7 °C

 

Pdh Tj = 12°C

7.80 kW

COP Tj = 12°C

6.05

Cdh Tj = +12 °C

 

Pdh Tj = Tbiv

7.70 kW

COP Tj = Tbiv

5.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.29

WTOL

60 °C

Poff

0 W

PTO

55 W

PSB

10 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

1.84 kW

Annual energy consumption Qhe

4238 kWh

Average Climate

EN 12102-1

Sound power level indoor

50 dB(A)

EN 14825

ηs

204 %

Prated

8.00 kW

SCOP

5.30

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

7.60 kW

COP Tj = -7°C

4.82

Cdh Tj = -7 °C

 

Pdh Tj = +2°C

7.70 kW

COP Tj = +2°C

5.22

Cdh Tj = +2 °C

 

Pdh Tj = +7°C

7.80 kW

COP Tj = +7°C

5.62

Cdh Tj = +7 °C

 

Pdh Tj = 12°C

7.80 kW

COP Tj = 12°C

6.08

Cdh Tj = +12 °C

 

Pdh Tj = Tbiv

7.60 kW

COP Tj = Tbiv

4.76

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.76

WTOL

60 °C

Poff

0 W

PTO

55 W

PSB

10 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

2964 kWh

TERRA 8 HPLB, average climate
Configure model
Model name
TERRA 8 HPLB, average climate
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.60 kW

6.90 kW

El input

1.60 kW

2.53 kW

COP

4.76

2.73

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

131 %

Prated

8.00 kW

7.00 kW

SCOP

5.30

3.48

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.60 kW

7.00 kW

COP Tj = -7°C

4.82

2.86

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

7.70 kW

7.20 kW

COP Tj = +2°C

5.22

3.41

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

7.80 kW

7.40 kW

COP Tj = +7°C

5.62

3.85

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

7.80 kW

7.50 kW

COP Tj = 12°C

6.08

4.39

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

7.60 kW

6.90 kW

COP Tj = Tbiv

4.76

2.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

6.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.76

2.73

WTOL

60 °C

60 °C

Poff

0 W

0 W

PTO

55 W

55 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2964 kWh

4113 kWh