1,100 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.33 kW
8.49 kW
El input
2.20 kW
2.85 kW
COP
4.24
2.97
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
144 %
121 %
Prated
8.84 kW
8.13 kW
SCOP
3.67
3.09
Tbiv
-4 °C
-4 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.18 kW
5.81 kW
COP Tj = -7°C
2.74
2.15
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
7.55 kW
7.22 kW
COP Tj = +2°C
3.76
3.05
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
9.52 kW
9.29 kW
COP Tj = +7°C
4.59
4.12
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
10.97 kW
10.91 kW
COP Tj = 12°C
4.92
4.84
Cdh Tj = +12 °C
1.000
1.000
Pdh Tj = Tbiv
6.64 kW
6.25 kW
COP Tj = Tbiv
3.07
2.40
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.78 kW
5.38 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.97
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
62 °C
62 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.86 kW
2.75 kW
Annual energy consumption Qhe
4867 kWh
5440 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.33 kW
8.49 kW
El input
2.20 kW
2.85 kW
COP
4.24
2.97
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
144 %
121 %
Prated
8.84 kW
8.13 kW
SCOP
3.67
3.09
Tbiv
-4 °C
-4 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.18 kW
5.81 kW
COP Tj = -7°C
2.74
2.15
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
7.55 kW
7.22 kW
COP Tj = +2°C
3.76
3.05
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
9.52 kW
9.29 kW
COP Tj = +7°C
4.59
4.12
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
10.97 kW
10.91 kW
COP Tj = 12°C
4.92
4.84
Cdh Tj = +12 °C
1.000
1.000
Pdh Tj = Tbiv
6.64 kW
6.25 kW
COP Tj = Tbiv
3.07
2.40
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.78 kW
5.38 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.97
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
62 °C
62 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.86 kW
2.75 kW
Annual energy consumption Qhe
4867 kWh
5440 kWh