Certificate holders

Subtype

LWD 50A/SX

Certificate Holder
ait-deutschland GmbH
Industriestr. 3
95359 Kasendorf
Germany
Registration number
041-K001-43 / 1
Certification Body
BRE
Subtype title
LWD 50A/SX
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,950 kg

Certification Date
24.11.2020
Testing basis
HP Keymark Scheme Rules Rev 08
Testing laboratory
Universität Stuttgart, Prüfstelle HLK am Institut für Gebäudeenergetik, Thermotechnik und Energiespeicherung (IGTE), DE
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

LWD 50A/SX-HMD
Configure model
Model name
LWD 50A/SX-HMD
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.85 kW

6.04 kW

El input

1.53 kW

2.01 kW

COP

4.46

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

189 %

155 %

Prated

7.07 kW

6.54 kW

SCOP

4.79

3.95

Tbiv

4 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.47 kW

5.16 kW

COP Tj = +2°C

3.70

2.62

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

6.94 kW

6.40 kW

COP Tj = +7°C

4.69

3.56

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

7.51 kW

7.41 kW

COP Tj = 12°C

5.53

5.01

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

6.06 kW

5.60 kW

COP Tj = Tbiv

4.15

2.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.47 kW

5.16 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.70

2.62

WTOL

62 °C

62 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.38 kW

Annual energy consumption Qhe

1971 kWh

2211 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

135 %

114 %

Prated

5.43 kW

4.98 kW

SCOP

3.44

2.93

Tbiv

-12 °C

-12 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.64 kW

4.31 kW

COP Tj = -7°C

3.19

2.58

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

5.55 kW

5.44 kW

COP Tj = +2°C

4.07

3.51

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

7.08 kW

6.97 kW

COP Tj = +7°C

4.93

4.63

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

7.54 kW

7.56 kW

COP Tj = 12°C

5.29

5.39

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

4.00 kW

3.67 kW

COP Tj = Tbiv

2.84

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.94 kW

2.72 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.18

1.61

WTOL

62 °C

62 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.43 kW

4.98 kW

Annual energy consumption Qhe

3888 kWh

4185 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.61

3.30

COP Tj = -15°C (if TOL<-20°C)

2.60

1.97

Cdh Tj = -15 °C

1.00

1.00

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

127 %

Prated

6.37 kW

5.91 kW

SCOP

3.88

3.25

Tbiv

-4 °C

-4 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.57 kW

4.11 kW

COP Tj = -7°C

3.04

2.28

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

5.52 kW

5.36 kW

COP Tj = +2°C

3.94

3.23

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

7.03 kW

6.81 kW

COP Tj = +7°C

4.87

4.32

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

7.54 kW

7.51 kW

COP Tj = 12°C

5.54

5.36

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

4.90 kW

4.55 kW

COP Tj = Tbiv

3.35

2.57

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.18 kW

3.72 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.81

2.05

WTOL

62 °C

1 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.19 kW

2.19 kW

Annual energy consumption Qhe

3388 kWh

3762 kWh

LWD 50A/SX-HTD S
Configure model
Model name
LWD 50A/SX-HTD S
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.85 kW

6.04 kW

El input

1.53 kW

2.01 kW

COP

4.46

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

189 %

155 %

Prated

7.07 kW

6.54 kW

SCOP

4.79

3.95

Tbiv

4 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.47 kW

5.16 kW

COP Tj = +2°C

3.70

2.62

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

6.94 kW

6.40 kW

COP Tj = +7°C

4.69

3.56

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

7.51 kW

7.41 kW

COP Tj = 12°C

5.53

5.01

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

6.06 kW

5.60 kW

COP Tj = Tbiv

4.15

2.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.47 kW

5.16 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.70

2.62

WTOL

62 °C

62 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.38 kW

Annual energy consumption Qhe

1971 kWh

2211 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

135 %

114 %

Prated

5.43 kW

4.98 kW

SCOP

3.44

2.93

Tbiv

-12 °C

-12 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.64 kW

4.31 kW

COP Tj = -7°C

3.19

2.58

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

5.55 kW

5.44 kW

COP Tj = +2°C

4.07

3.51

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

7.08 kW

6.97 kW

COP Tj = +7°C

4.93

4.63

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

7.54 kW

7.56 kW

COP Tj = 12°C

5.29

5.39

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

4.00 kW

3.67 kW

COP Tj = Tbiv

2.84

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.94 kW

2.72 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.18

1.61

WTOL

62 °C

62 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.43 kW

4.98 kW

Annual energy consumption Qhe

3888 kWh

4185 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.61

3.30

COP Tj = -15°C (if TOL<-20°C)

2.60

1.97

Cdh Tj = -15 °C

1.00

1.00

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

127 %

Prated

6.37 kW

5.91 kW

SCOP

3.88

3.25

Tbiv

-4 °C

-4 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.57 kW

4.11 kW

COP Tj = -7°C

3.04

2.28

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

5.52 kW

5.36 kW

COP Tj = +2°C

3.94

3.23

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

7.03 kW

6.81 kW

COP Tj = +7°C

4.87

4.32

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

7.54 kW

7.51 kW

COP Tj = 12°C

5.54

5.36

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

4.90 kW

4.55 kW

COP Tj = Tbiv

3.35

2.57

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.18 kW

3.72 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.81

2.05

WTOL

62 °C

1 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.19 kW

2.19 kW

Annual energy consumption Qhe

3388 kWh

3762 kWh