Certificate holders

Subtype

Vitocal 100-S/111-S | 4-6kW 230V

Certificate Holder
Viessmann Climate Solutions SE
Viessmannstr. 1
35107 Allendorf/Eder
Germany
Registration number
011-1W0401
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Vitocal 100-S/111-S | 4-6kW 230V
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

0,950 kg

Certification Date
02.11.2020
Testing basis
HP KEYMARK certification scheme rules rev. 7
Generate PDF Export model CSV
  • Number of models 16

Models

Vitocal 100-S AWB-M 101.B04
Configure model
Model name
Vitocal 100-S AWB-M 101.B04
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.08 kW

4.36 kW

El input

0.80 kW

1.80 kW

COP

5.10

2.42

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

150 %

Prated

4.90 kW

4.10 kW

SCOP

5.01

3.83

Tbiv

2 °C

2 °C

TOL

-20 °C

-20 °C

Pdh Tj = +2°C

4.94 kW

4.08 kW

COP Tj = +2°C

3.04

1.98

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.07 kW

2.95 kW

COP Tj = +7°C

5.03

3.25

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.57 kW

3.31 kW

COP Tj = 12°C

5.89

5.18

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

4.94 kW

4.08 kW

COP Tj = Tbiv

3.04

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.94 kW

4.08 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6552 kWh

5450 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

135 %

86 %

Prated

4.40 kW

2.80 kW

SCOP

3.46

2.22

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

2.76 kW

1.85 kW

COP Tj = -7°C

2.91

1.72

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.23 kW

2.09 kW

COP Tj = +2°C

4.44

2.72

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.14 kW

2.88 kW

COP Tj = +7°C

6.20

4.76

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.53 kW

3.27 kW

COP Tj = 12°C

5.46

5.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

3.62 kW

2.30 kW

COP Tj = Tbiv

1.65

1.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.30 kW

1.06 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.21

0.32

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.43 kW

2.82 kW

Annual energy consumption Qhe

10662 kWh

6791 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

3.70 kW

ηs

175 %

126 %

Prated

4.00 kW

3.70 kW

SCOP

4.45

3.22

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.51 kW

3.31 kW

COP Tj = -7°C

2.84

1.89

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.45 kW

2.65 kW

COP Tj = +2°C

2.84

3.18

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.14 kW

2.74 kW

COP Tj = +7°C

5.97

4.36

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.60 kW

3.27 kW

COP Tj = 12°C

8.78

6.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

3.51 kW

3.31 kW

COP Tj = Tbiv

2.84

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.83 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.14 kW

0.88 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

8202 kWh

7700 kWh

Vitocal 100-S AWB-M-E 101.B04
Configure model
Model name
Vitocal 100-S AWB-M-E 101.B04
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.08 kW

4.36 kW

El input

0.80 kW

1.80 kW

COP

5.10

2.42

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

150 %

Prated

4.90 kW

4.10 kW

SCOP

5.01

3.83

Tbiv

2 °C

2 °C

TOL

-20 °C

-20 °C

Pdh Tj = +2°C

4.94 kW

4.08 kW

COP Tj = +2°C

3.04

1.98

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.07 kW

2.95 kW

COP Tj = +7°C

5.03

3.25

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.57 kW

3.31 kW

COP Tj = 12°C

5.89

5.18

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

4.94 kW

4.08 kW

COP Tj = Tbiv

3.04

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.94 kW

4.08 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6552 kWh

5450 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

135 %

86 %

Prated

4.40 kW

2.80 kW

SCOP

3.46

2.22

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

2.76 kW

1.85 kW

COP Tj = -7°C

2.91

1.72

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.23 kW

2.09 kW

COP Tj = +2°C

4.44

2.72

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.14 kW

2.88 kW

COP Tj = +7°C

6.20

4.76

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.53 kW

3.27 kW

COP Tj = 12°C

5.46

5.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

3.62 kW

2.30 kW

COP Tj = Tbiv

1.65

1.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.30 kW

1.06 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.21

0.32

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.43 kW

2.82 kW

Annual energy consumption Qhe

10662 kWh

6791 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

3.70 kW

ηs

175 %

126 %

Prated

4.00 kW

3.70 kW

SCOP

4.45

3.22

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.51 kW

3.31 kW

COP Tj = -7°C

2.84

1.89

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.45 kW

2.65 kW

COP Tj = +2°C

2.84

3.18

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.14 kW

2.74 kW

COP Tj = +7°C

5.97

4.36

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.60 kW

3.27 kW

COP Tj = 12°C

8.78

6.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

3.51 kW

3.31 kW

COP Tj = Tbiv

2.84

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.83 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.14 kW

0.88 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

8202 kWh

7700 kWh

Vitocal 100-S AWB-M-E-AC 101.B04
Configure model
Model name
Vitocal 100-S AWB-M-E-AC 101.B04
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.08 kW

4.36 kW

El input

0.80 kW

1.80 kW

COP

5.10

2.42

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

150 %

Prated

4.90 kW

4.10 kW

SCOP

5.01

3.83

Tbiv

2 °C

2 °C

TOL

-20 °C

-20 °C

Pdh Tj = +2°C

4.94 kW

4.08 kW

COP Tj = +2°C

3.04

1.98

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.07 kW

2.95 kW

COP Tj = +7°C

5.03

3.25

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.57 kW

3.31 kW

COP Tj = 12°C

5.89

5.18

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

4.94 kW

4.08 kW

COP Tj = Tbiv

3.04

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.94 kW

4.08 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6552 kWh

5450 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

135 %

86 %

Prated

4.40 kW

2.80 kW

SCOP

3.46

2.22

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

2.76 kW

1.85 kW

COP Tj = -7°C

2.91

1.72

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.23 kW

2.09 kW

COP Tj = +2°C

4.44

2.72

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.14 kW

2.88 kW

COP Tj = +7°C

6.20

4.76

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.53 kW

3.27 kW

COP Tj = 12°C

5.46

5.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

3.62 kW

2.30 kW

COP Tj = Tbiv

1.65

1.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.30 kW

1.06 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.21

0.32

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.43 kW

2.82 kW

Annual energy consumption Qhe

10662 kWh

6791 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

3.70 kW

ηs

175 %

126 %

Prated

4.00 kW

3.70 kW

SCOP

4.45

3.22

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.51 kW

3.31 kW

COP Tj = -7°C

2.84

1.89

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.45 kW

2.65 kW

COP Tj = +2°C

2.84

3.18

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.14 kW

2.74 kW

COP Tj = +7°C

5.97

4.36

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.60 kW

3.27 kW

COP Tj = 12°C

8.78

6.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

3.51 kW

3.31 kW

COP Tj = Tbiv

2.84

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.83 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.14 kW

0.88 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

8202 kWh

7700 kWh

Vitocal 100-S AWB-M-E-AC 101.B04 F
Configure model
Model name
Vitocal 100-S AWB-M-E-AC 101.B04 F
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.08 kW

4.36 kW

El input

0.80 kW

1.80 kW

COP

5.10

2.42

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

150 %

Prated

4.90 kW

4.10 kW

SCOP

5.01

3.83

Tbiv

2 °C

2 °C

TOL

-20 °C

-20 °C

Pdh Tj = +2°C

4.94 kW

4.08 kW

COP Tj = +2°C

3.04

1.98

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.07 kW

2.95 kW

COP Tj = +7°C

5.03

3.25

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.57 kW

3.31 kW

COP Tj = 12°C

5.89

5.18

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

4.94 kW

4.08 kW

COP Tj = Tbiv

3.04

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.94 kW

4.08 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6552 kWh

5450 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

135 %

86 %

Prated

4.40 kW

2.80 kW

SCOP

3.46

2.22

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

2.76 kW

1.85 kW

COP Tj = -7°C

2.91

1.72

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.23 kW

2.09 kW

COP Tj = +2°C

4.44

2.72

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.14 kW

2.88 kW

COP Tj = +7°C

6.20

4.76

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.53 kW

3.27 kW

COP Tj = 12°C

5.46

5.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

3.62 kW

2.30 kW

COP Tj = Tbiv

1.65

1.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.30 kW

1.06 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.21

0.32

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.43 kW

2.82 kW

Annual energy consumption Qhe

10662 kWh

6791 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

3.70 kW

ηs

175 %

126 %

Prated

4.00 kW

3.70 kW

SCOP

4.45

3.22

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.51 kW

3.31 kW

COP Tj = -7°C

2.84

1.89

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.45 kW

2.65 kW

COP Tj = +2°C

2.84

3.18

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.14 kW

2.74 kW

COP Tj = +7°C

5.97

4.36

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.60 kW

3.27 kW

COP Tj = 12°C

8.78

6.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

3.51 kW

3.31 kW

COP Tj = Tbiv

2.84

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.83 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.14 kW

0.88 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

8202 kWh

7700 kWh

Vitocal 111-S AWBT-M-AC 111.B04
Configure model
Model name
Vitocal 111-S AWBT-M-AC 111.B04
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.08 kW

4.36 kW

El input

0.80 kW

1.80 kW

COP

5.10

2.42

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

3.70 kW

ηs

175 %

126 %

Prated

4.00 kW

3.70 kW

SCOP

4.45

3.22

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.51 kW

3.31 kW

COP Tj = -7°C

2.84

1.89

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.45 kW

2.65 kW

COP Tj = +2°C

2.84

3.18

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.14 kW

2.74 kW

COP Tj = +7°C

5.97

4.36

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.60 kW

3.27 kW

COP Tj = 12°C

8.78

6.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

3.51 kW

3.31 kW

COP Tj = Tbiv

2.84

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.83 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.14 kW

0.88 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

8202 kWh

7700 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.32

Heating up time

2:15 h:min

Standby power input

25.0 W

Reference hot water temperature

53.4 °C

Mixed water at 40°C

296.1 l

Vitocal 111-S AWBT-M-E 111.B04
Configure model
Model name
Vitocal 111-S AWBT-M-E 111.B04
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.08 kW

4.36 kW

El input

0.80 kW

1.80 kW

COP

5.10

2.42

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

3.70 kW

ηs

175 %

126 %

Prated

4.00 kW

3.70 kW

SCOP

4.45

3.22

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.51 kW

3.31 kW

COP Tj = -7°C

2.84

1.89

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.45 kW

2.65 kW

COP Tj = +2°C

2.84

3.18

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.14 kW

2.74 kW

COP Tj = +7°C

5.97

4.36

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.60 kW

3.27 kW

COP Tj = 12°C

8.78

6.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

3.51 kW

3.31 kW

COP Tj = Tbiv

2.84

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.83 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.14 kW

0.88 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

8202 kWh

7700 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.32

Heating up time

2:15 h:min

Standby power input

25.0 W

Reference hot water temperature

53.4 °C

Mixed water at 40°C

296.1 l

Vitocal 111-S AWBT-M-E-AC 111.B04
Configure model
Model name
Vitocal 111-S AWBT-M-E-AC 111.B04
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.08 kW

4.36 kW

El input

0.80 kW

1.80 kW

COP

5.10

2.42

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

3.70 kW

ηs

175 %

126 %

Prated

4.00 kW

3.70 kW

SCOP

4.45

3.22

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.51 kW

3.31 kW

COP Tj = -7°C

2.84

1.89

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.45 kW

2.65 kW

COP Tj = +2°C

2.84

3.18

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.14 kW

2.74 kW

COP Tj = +7°C

5.97

4.36

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.60 kW

3.27 kW

COP Tj = 12°C

8.78

6.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

3.51 kW

3.31 kW

COP Tj = Tbiv

2.84

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.83 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.14 kW

0.88 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

8202 kWh

7700 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.32

Heating up time

2:15 h:min

Standby power input

25.2 W

Reference hot water temperature

53.4 °C

Mixed water at 40°C

296.1 l

Vitocal 100-S AWB-M 101.B06
Configure model
Model name
Vitocal 100-S AWB-M 101.B06
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.02 kW

4.36 kW

El input

1.23 kW

1.80 kW

COP

4.90

2.42

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

156 %

Prated

5.70 kW

4.10 kW

SCOP

5.70

3.97

Tbiv

2 °C

2 °C

TOL

-20 °C

-20 °C

Pdh Tj = +2°C

5.01 kW

4.08 kW

COP Tj = +2°C

4.30

1.98

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.28 kW

2.95 kW

COP Tj = +7°C

4.86

3.25

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.43 kW

3.31 kW

COP Tj = 12°C

7.69

5.59

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

5.01 kW

4.08 kW

COP Tj = Tbiv

2.97

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.01 kW

4.08 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.97

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6687 kWh

5450 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

135 %

90 %

Prated

4.80 kW

3.30 kW

SCOP

3.46

2.32

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.10 kW

2.10 kW

COP Tj = -7°C

2.89

1.81

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.40 kW

2.09 kW

COP Tj = +2°C

4.40

2.72

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.14 kW

2.88 kW

COP Tj = +7°C

6.20

4.76

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.43 kW

3.34 kW

COP Tj = 12°C

8.00

6.85

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

3.90 kW

2.67 kW

COP Tj = Tbiv

2.11

1.51

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.30 kW

1.06 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.21

0.32

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.78 kW

3.27 kW

Annual energy consumption Qhe

11493 kWh

7870 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

3.70 kW

ηs

175 %

125 %

Prated

5.10 kW

4.10 kW

SCOP

4.45

3.20

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.53 kW

3.31 kW

COP Tj = -7°C

2.85

1.89

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.04 kW

2.65 kW

COP Tj = +2°C

4.30

3.18

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.11 kW

2.74 kW

COP Tj = +7°C

5.93

4.76

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.60 kW

3.27 kW

COP Tj = 12°C

8.40

6.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

4.53 kW

3.59 kW

COP Tj = Tbiv

2.85

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.08 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.04 kW

1.20 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

10549 kWh

8383 kWh

Vitocal 100-S AWB-M-E 101.B06
Configure model
Model name
Vitocal 100-S AWB-M-E 101.B06
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.02 kW

4.36 kW

El input

1.23 kW

1.80 kW

COP

4.90

2.42

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

156 %

Prated

5.70 kW

4.10 kW

SCOP

5.70

3.97

Tbiv

2 °C

2 °C

TOL

-20 °C

-20 °C

Pdh Tj = +2°C

5.01 kW

4.08 kW

COP Tj = +2°C

4.30

1.98

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.28 kW

2.95 kW

COP Tj = +7°C

4.86

3.25

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.43 kW

3.31 kW

COP Tj = 12°C

7.69

5.59

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

5.01 kW

4.08 kW

COP Tj = Tbiv

2.97

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.01 kW

4.08 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.97

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6687 kWh

5450 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

135 %

90 %

Prated

4.80 kW

3.30 kW

SCOP

3.46

2.32

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.10 kW

2.10 kW

COP Tj = -7°C

2.89

1.81

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.40 kW

2.09 kW

COP Tj = +2°C

4.40

2.72

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.14 kW

2.88 kW

COP Tj = +7°C

6.20

4.76

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.43 kW

3.34 kW

COP Tj = 12°C

8.00

6.85

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

3.90 kW

2.67 kW

COP Tj = Tbiv

2.11

1.51

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.30 kW

1.06 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.21

0.32

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.78 kW

3.27 kW

Annual energy consumption Qhe

11493 kWh

7870 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

3.70 kW

ηs

175 %

125 %

Prated

5.10 kW

4.10 kW

SCOP

4.45

3.20

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.53 kW

3.31 kW

COP Tj = -7°C

2.85

1.89

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.04 kW

2.65 kW

COP Tj = +2°C

4.30

3.18

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.11 kW

2.74 kW

COP Tj = +7°C

5.93

4.76

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.60 kW

3.27 kW

COP Tj = 12°C

8.40

6.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

4.53 kW

3.59 kW

COP Tj = Tbiv

2.85

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.08 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.04 kW

1.20 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

10549 kWh

8383 kWh

Vitocal 100-S AWB-M-E-AC 101.B06
Configure model
Model name
Vitocal 100-S AWB-M-E-AC 101.B06
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.02 kW

4.36 kW

El input

1.23 kW

1.80 kW

COP

4.90

2.42

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

156 %

Prated

5.70 kW

4.10 kW

SCOP

5.70

3.97

Tbiv

2 °C

2 °C

TOL

-20 °C

-20 °C

Pdh Tj = +2°C

5.01 kW

4.08 kW

COP Tj = +2°C

4.30

1.98

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.28 kW

2.95 kW

COP Tj = +7°C

4.86

3.25

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.43 kW

3.31 kW

COP Tj = 12°C

7.69

5.59

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

5.01 kW

4.08 kW

COP Tj = Tbiv

2.97

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.01 kW

4.08 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.97

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6687 kWh

5450 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

135 %

90 %

Prated

4.80 kW

3.30 kW

SCOP

3.46

2.32

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.10 kW

2.10 kW

COP Tj = -7°C

2.89

1.81

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.40 kW

2.09 kW

COP Tj = +2°C

4.40

2.72

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.14 kW

2.88 kW

COP Tj = +7°C

6.20

4.76

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.43 kW

3.34 kW

COP Tj = 12°C

8.00

6.85

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

3.90 kW

2.67 kW

COP Tj = Tbiv

2.11

1.51

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.30 kW

1.06 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.21

0.32

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.78 kW

3.27 kW

Annual energy consumption Qhe

11493 kWh

7870 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

3.70 kW

ηs

175 %

125 %

Prated

5.10 kW

4.10 kW

SCOP

4.45

3.20

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.53 kW

3.31 kW

COP Tj = -7°C

2.85

1.89

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.04 kW

2.65 kW

COP Tj = +2°C

4.30

3.18

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.11 kW

2.74 kW

COP Tj = +7°C

5.93

4.76

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.60 kW

3.27 kW

COP Tj = 12°C

8.40

6.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

4.53 kW

3.59 kW

COP Tj = Tbiv

2.85

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.08 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.04 kW

1.20 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

10549 kWh

8383 kWh

Vitocal 100-S AWB-M-E-AC 101.B06 F
Configure model
Model name
Vitocal 100-S AWB-M-E-AC 101.B06 F
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.02 kW

4.36 kW

El input

1.23 kW

1.80 kW

COP

4.90

2.42

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

156 %

Prated

5.70 kW

4.10 kW

SCOP

5.70

3.97

Tbiv

2 °C

2 °C

TOL

-20 °C

-20 °C

Pdh Tj = +2°C

5.01 kW

4.08 kW

COP Tj = +2°C

4.30

1.98

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.28 kW

2.95 kW

COP Tj = +7°C

4.86

3.25

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.43 kW

3.31 kW

COP Tj = 12°C

7.69

5.59

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

5.01 kW

4.08 kW

COP Tj = Tbiv

2.97

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.01 kW

4.08 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.97

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6687 kWh

5450 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

135 %

90 %

Prated

4.80 kW

3.30 kW

SCOP

3.46

2.32

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.10 kW

2.10 kW

COP Tj = -7°C

2.89

1.81

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.40 kW

2.09 kW

COP Tj = +2°C

4.40

2.72

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.14 kW

2.88 kW

COP Tj = +7°C

6.20

4.76

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.43 kW

3.34 kW

COP Tj = 12°C

8.00

6.85

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

3.90 kW

2.67 kW

COP Tj = Tbiv

2.11

1.51

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.30 kW

1.06 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.21

0.32

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.78 kW

3.27 kW

Annual energy consumption Qhe

11493 kWh

7870 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

3.70 kW

ηs

175 %

125 %

Prated

5.10 kW

4.10 kW

SCOP

4.45

3.20

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.53 kW

3.31 kW

COP Tj = -7°C

2.85

1.89

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.04 kW

2.65 kW

COP Tj = +2°C

4.30

3.18

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.11 kW

2.74 kW

COP Tj = +7°C

5.93

4.76

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.60 kW

3.27 kW

COP Tj = 12°C

8.40

6.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

4.53 kW

3.59 kW

COP Tj = Tbiv

2.85

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.08 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.04 kW

1.20 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

10549 kWh

8383 kWh

Vitocal 111-S AWBT-M-AC 111.B06
Configure model
Model name
Vitocal 111-S AWBT-M-AC 111.B06
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.02 kW

4.36 kW

El input

1.23 kW

1.80 kW

COP

4.90

2.42

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

3.70 kW

ηs

175 %

125 %

Prated

5.10 kW

4.10 kW

SCOP

4.45

3.20

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.53 kW

3.31 kW

COP Tj = -7°C

2.85

1.89

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.04 kW

2.65 kW

COP Tj = +2°C

4.30

3.18

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.11 kW

2.74 kW

COP Tj = +7°C

5.93

4.76

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.60 kW

3.27 kW

COP Tj = 12°C

8.40

6.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

4.53 kW

3.59 kW

COP Tj = Tbiv

2.85

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.08 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.04 kW

1.20 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

10549 kWh

8383 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.32

Heating up time

2:15 h:min

Standby power input

25.0 W

Reference hot water temperature

53.4 °C

Mixed water at 40°C

296.1 l

Vitocal 111-S AWBT-M-E 111.B06
Configure model
Model name
Vitocal 111-S AWBT-M-E 111.B06
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.02 kW

4.36 kW

El input

1.23 kW

1.80 kW

COP

4.90

2.42

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

3.70 kW

ηs

175 %

125 %

Prated

5.10 kW

4.10 kW

SCOP

4.45

3.20

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.53 kW

3.31 kW

COP Tj = -7°C

2.85

1.89

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.04 kW

2.65 kW

COP Tj = +2°C

4.30

3.18

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.11 kW

2.74 kW

COP Tj = +7°C

5.93

4.76

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.60 kW

3.27 kW

COP Tj = 12°C

8.40

6.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

4.53 kW

3.59 kW

COP Tj = Tbiv

2.85

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.08 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.04 kW

1.20 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

10549 kWh

8383 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.32

Heating up time

2:15 h:min

Standby power input

25.0 W

Reference hot water temperature

53.4 °C

Mixed water at 40°C

296.1 l

Vitocal 111-S AWBT-M-E-AC 111.B06
Configure model
Model name
Vitocal 111-S AWBT-M-E-AC 111.B06
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.02 kW

4.36 kW

El input

1.23 kW

1.80 kW

COP

4.90

2.42

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

3.70 kW

ηs

175 %

125 %

Prated

5.10 kW

4.10 kW

SCOP

4.45

3.20

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.53 kW

3.31 kW

COP Tj = -7°C

2.85

1.89

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.04 kW

2.65 kW

COP Tj = +2°C

4.30

3.18

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.11 kW

2.74 kW

COP Tj = +7°C

5.93

4.76

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.60 kW

3.27 kW

COP Tj = 12°C

8.40

6.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

4.53 kW

3.59 kW

COP Tj = Tbiv

2.85

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.08 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.04 kW

1.20 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

10549 kWh

8383 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.32

Heating up time

2:15 h:min

Standby power input

25.0 W

Reference hot water temperature

53.4 °C

Mixed water at 40°C

296.1 l

Vitocal 111-S AWBT-M-E-AC 111.B06 F
Configure model
Model name
Vitocal 111-S AWBT-M-E-AC 111.B06 F
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.02 kW

4.36 kW

El input

1.23 kW

1.80 kW

COP

4.90

2.42

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

3.70 kW

ηs

175 %

125 %

Prated

5.10 kW

4.10 kW

SCOP

4.45

3.20

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.53 kW

3.31 kW

COP Tj = -7°C

2.85

1.89

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

3.04 kW

2.65 kW

COP Tj = +2°C

4.30

3.18

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.11 kW

2.74 kW

COP Tj = +7°C

5.93

4.76

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.60 kW

3.27 kW

COP Tj = 12°C

8.40

6.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

4.53 kW

3.59 kW

COP Tj = Tbiv

2.85

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.08 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.04 kW

1.20 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

10549 kWh

8383 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.32

Heating up time

2:15 h:min

Standby power input

25.0 W

Reference hot water temperature

53.4 °C

Mixed water at 40°C

296.1 l

Vitocal 111-S AWBT-M-E-AC 111.B04 F
Configure model
Model name
Vitocal 111-S AWBT-M-E-AC 111.B04 F
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.08 kW

4.36 kW

El input

0.80 kW

1.80 kW

COP

5.10

2.42

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

3.70 kW

ηs

175 %

126 %

Prated

4.00 kW

3.70 kW

SCOP

4.45

3.22

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.51 kW

3.31 kW

COP Tj = -7°C

2.84

1.89

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.45 kW

2.65 kW

COP Tj = +2°C

2.84

3.18

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.14 kW

2.74 kW

COP Tj = +7°C

5.97

4.36

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

3.60 kW

3.27 kW

COP Tj = 12°C

8.78

6.35

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

3.51 kW

3.31 kW

COP Tj = Tbiv

2.84

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.83 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

0 W

0 W

PSB

0 W

0 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.14 kW

0.88 kW

Backup Heater

0.00 kW

Annual energy consumption Qhe

8202 kWh

7700 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.32

Heating up time

2:15 h:min

Standby power input

25.0 W

Reference hot water temperature

53.4 °C

Mixed water at 40°C

296.1 l