2,300 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
16.63 kW
15.41 kW
El input
3.86 kW
5.50 kW
COP
4.31
2.80
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
134 %
Prated
19.00 kW
18.00 kW
SCOP
4.63
3.55
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
17.00 kW
15.70 kW
COP Tj = -7°C
4.48
2.97
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
17.10 kW
16.30 kW
COP Tj = +2°C
4.68
3.58
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
17.20 kW
16.70 kW
COP Tj = +7°C
4.88
3.95
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
17.30 kW
17.00 kW
COP Tj = 12°C
5.08
4.32
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
17.00 kW
15.70 kW
COP Tj = Tbiv
4.48
2.97
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
16.50 kW
15.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.22
2.74
WTOL
55 °C
55 °C
Poff
2 W
2 W
PTO
90 W
90 W
PSB
3 W
3 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.70 kW
2.30 kW
Annual energy consumption Qhe
8604 kWh
10337 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
22.13 kW
20.14 kW
El input
4.25 kW
5.69 kW
COP
5.21
3.54
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
217 %
176 %
Prated
25.00 kW
23.00 kW
SCOP
5.63
4.60
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
21.80 kW
20.20 kW
COP Tj = -7°C
5.42
3.76
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
22.00 kW
20.80 kW
COP Tj = +2°C
5.68
4.64
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
22.10 kW
21.20 kW
COP Tj = +7°C
5.94
5.18
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
22.80 kW
21.60 kW
COP Tj = 12°C
6.20
5.72
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
21.80 kW
20.20 kW
COP Tj = Tbiv
5.42
3.76
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
21.70 kW
19.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.29
3.54
WTOL
55 °C
55 °C
Poff
2 W
2 W
PTO
90 W
90 W
PSB
3 W
3 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.00 kW
2.90 kW
Annual energy consumption Qhe
9057 kWh
10272 kWh