Certificate holders

Subtype

ATLANTIC GEOLIA 13

Certificate Holder
Groupe Atlantic
44 boulevard des Etats-Unis
85000 La Roche Sur Yon
France
Registration number
012-C700082 / Issue 1
Certification Body
RISE CERT
Subtype title
ATLANTIC GEOLIA 13
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R410A
Mass of Refrigerant

1,700 kg

Certification Date
16.10.2020
Testing basis
HP Keymark Scheme Rules rev 8
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

ATLANTIC GEOLIA 13
Configure model
Model name
ATLANTIC GEOLIA 13
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

12.63 kW

11.86 kW

El input

2.91 kW

4.06 kW

COP

4.35

2.92

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

14.00 kW

13.00 kW

SCOP

4.62

3.70

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.60 kW

11.90 kW

COP Tj = -7°C

4.53

3.43

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

12.70 kW

12.20 kW

COP Tj = +2°C

4.70

3.65

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

12.80 kW

12.40 kW

COP Tj = +7°C

4.86

4.07

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

12.90 kW

12.60 kW

COP Tj = 12°C

5.02

4.47

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

12.60 kW

11.90 kW

COP Tj = Tbiv

4.53

3.43

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.60 kW

11.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.26

2.86

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

90 W

90 W

PSB

3 W

3 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.70 kW

1.60 kW

Annual energy consumption Qhe

6386 kWh

7546 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

16.78 kW

15.59 kW

El input

2.94 kW

4.68 kW

COP

5.70

3.33

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

210 %

164 %

Prated

18.00 kW

16.00 kW

SCOP

5.44

4.29

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.10 kW

13.90 kW

COP Tj = -7°C

5.17

3.43

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

16.30 kW

14.70 kW

COP Tj = +2°C

5.50

4.35

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

16.50 kW

15.20 kW

COP Tj = +7°C

5.81

4.92

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

16.70 kW

15.70 kW

COP Tj = 12°C

6.14

5.51

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

16.10 kW

13.90 kW

COP Tj = Tbiv

5.17

3.43

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.10 kW

13.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.11

3.11

WTOL

55 °C

55 °C

Poff

2 W

2 W

PTO

90 W

90 W

PSB

3 W

3 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

2.10 kW

Annual energy consumption Qhe

6912 kWh

7576 kWh