1,700 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
12.63 kW
11.86 kW
El input
2.91 kW
4.06 kW
COP
4.35
2.92
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
140 %
Prated
14.00 kW
13.00 kW
SCOP
4.62
3.70
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.60 kW
11.90 kW
COP Tj = -7°C
4.53
3.43
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
12.70 kW
12.20 kW
COP Tj = +2°C
4.70
3.65
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
12.80 kW
12.40 kW
COP Tj = +7°C
4.86
4.07
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
12.90 kW
12.60 kW
COP Tj = 12°C
5.02
4.47
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
12.60 kW
11.90 kW
COP Tj = Tbiv
4.53
3.43
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.60 kW
11.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.26
2.86
WTOL
55 °C
55 °C
Poff
2 W
2 W
PTO
90 W
90 W
PSB
3 W
3 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.70 kW
1.60 kW
Annual energy consumption Qhe
6386 kWh
7546 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
16.78 kW
15.59 kW
El input
2.94 kW
4.68 kW
COP
5.70
3.33
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
210 %
164 %
Prated
18.00 kW
16.00 kW
SCOP
5.44
4.29
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
16.10 kW
13.90 kW
COP Tj = -7°C
5.17
3.43
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
16.30 kW
14.70 kW
COP Tj = +2°C
5.50
4.35
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
16.50 kW
15.20 kW
COP Tj = +7°C
5.81
4.92
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
16.70 kW
15.70 kW
COP Tj = 12°C
6.14
5.51
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
16.10 kW
13.90 kW
COP Tj = Tbiv
5.17
3.43
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
16.10 kW
13.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.11
3.11
WTOL
55 °C
55 °C
Poff
2 W
2 W
PTO
90 W
90 W
PSB
3 W
3 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.10 kW
2.10 kW
Annual energy consumption Qhe
6912 kWh
7576 kWh