0,950 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.02 kW
kW
El input
1.82 kW
kW
COP
3.86
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
57 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
153 %
%
Prated
8.00 kW
kW
SCOP
4.03
Tbiv
-7 °C
°C
TOL
-10 °C
°C
Pdh Tj = -7°C
7.00 kW
kW
COP Tj = -7°C
3.87
Cdh Tj = -7 °C
0.990
Pdh Tj = +2°C
7.20 kW
kW
COP Tj = +2°C
4.05
Cdh Tj = +2 °C
0.990
Pdh Tj = +7°C
7.20 kW
kW
COP Tj = +7°C
4.22
Cdh Tj = +7 °C
0.990
Pdh Tj = 12°C
7.30 kW
kW
COP Tj = 12°C
4.39
Cdh Tj = +12 °C
0.990
Pdh Tj = Tbiv
7.00 kW
kW
COP Tj = Tbiv
3.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.78
WTOL
50 °C
°C
Poff
2 W
W
PTO
14 W
W
PSB
4 W
W
PCK
0 W
W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.90 kW
kW
Annual energy consumption Qhe
4074 kWh
kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
9.35 kW
8.72 kW
El input
1.83 kW
3.04 kW
COP
5.10
2.87
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
194 %
149 %
Prated
11.00 kW
10.00 kW
SCOP
5.06
3.90
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.40 kW
8.50 kW
COP Tj = -7°C
4.80
3.30
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
9.50 kW
8.80 kW
COP Tj = +2°C
5.10
3.90
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
9.60 kW
9.00 kW
COP Tj = +7°C
5.30
4.30
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
9.70 kW
9.20 kW
COP Tj = 12°C
5.60
4.80
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
9.40 kW
8.50 kW
COP Tj = Tbiv
4.80
3.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.40 kW
8.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.70
3.00
WTOL
55 °C
55 °C
Poff
2 W
2 W
PTO
14 W
14 W
PSB
4 W
4 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.20 kW
1.20 kW
Annual energy consumption Qhe
4323 kWh
4997 kWh