Certificate holders

Subtype

Assure Mono 12 16

Certificate Holder
BAXI Heating UK Limited
Acordn House, Coventry road
CV34 4RT Warwick
United Kingdom
Registration number
ICIM-PDC-000082-00
Certification Body
ICIM S.p.A.
Subtype title
Assure Mono 12 16
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,800 kg

Certification Date
25.06.2020
Testing basis
HP KEYMARK certification scheme rules rev. 7
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

Assure Mono 12
Configure model
Model name
Assure Mono 12
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.30 kW

11.90 kW

El input

2.56 kW

4.28 kW

COP

4.81

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

dB(A)

dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

126 %

Prated

12.00 kW

13.00 kW

SCOP

4.29

3.23

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.52 kW

11.29 kW

COP Tj = -7°C

2.88

2.05

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

6.50 kW

7.31 kW

COP Tj = +2°C

4.15

3.14

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.12 kW

4.96 kW

COP Tj = +7°C

5.74

4.25

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

2.23 kW

2.37 kW

COP Tj = 12°C

5.40

4.94

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

10.52 kW

11.29 kW

COP Tj = Tbiv

2.88

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.01 kW

11.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

9 W

9 W

PTO

15 W

15 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.90 kW

Annual energy consumption Qhe

5726 kWh

8164 kWh

Assure Mono 16
Configure model
Model name
Assure Mono 16
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.30 kW

16.10 kW

El input

3.66 kW

5.90 kW

COP

4.45

2.73

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

dB(A)

dB(A)

Sound power level outdoor

71 dB(A)

71 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

128 %

Prated

16.00 kW

15.00 kW

SCOP

4.30

3.27

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.15 kW

12.90 kW

COP Tj = -7°C

2.72

2.04

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

8.92 kW

8.25 kW

COP Tj = +2°C

4.17

3.21

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

5.64 kW

5.45 kW

COP Tj = +7°C

5.86

4.32

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

2.47 kW

2.57 kW

COP Tj = 12°C

6.28

5.12

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

14.15 kW

12.90 kW

COP Tj = Tbiv

2.72

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.93 kW

11.16 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

9 W

9 W

PTO

41 W

41 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.10 kW

3.40 kW

Annual energy consumption Qhe

7687 kWh

9216 kWh