Certificate holders

Subtype

Assure Mono 5 7 9

Certificate Holder
BAXI Heating UK Limited
Acordn House, Coventry road
CV34 4RT Warwick
United Kingdom
Registration number
ICIM-PDC-000081-00
Certification Body
ICIM S.p.A.
Subtype title
Assure Mono 5 7 9
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,000 kg

Certification Date
25.06.2020
Testing basis
HP KEYMARK certification scheme rules rev. 7
Generate PDF Export model CSV Download certificate
  • Number of models 3

Models

Assure Mono 5
Configure model
Model name
Assure Mono 5
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.65 kW

4.65 kW

El input

0.93 kW

1.77 kW

COP

5.00

2.63

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

dB(A)

dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

127 %

Prated

7.00 kW

7.00 kW

SCOP

4.47

3.24

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.88 kW

5.83 kW

COP Tj = -7°C

2.91

1.97

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

3.64 kW

3.68 kW

COP Tj = +2°C

4.38

3.22

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

2.42 kW

2.47 kW

COP Tj = +7°C

5.89

4.21

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

1.03 kW

1.26 kW

COP Tj = 12°C

5.89

4.91

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

5.88 kW

5.83 kW

COP Tj = Tbiv

2.91

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.62 kW

5.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

9 W

9 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.70 kW

Annual energy consumption Qhe

3071 kWh

4203 kWh

Assure Mono 7
Configure model
Model name
Assure Mono 7
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.65 kW

6.80 kW

El input

1.35 kW

2.42 kW

COP

4.94

2.81

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

dB(A)

dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

127 %

Prated

7.00 kW

7.00 kW

SCOP

4.47

3.24

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.88 kW

5.83 kW

COP Tj = -7°C

2.91

1.97

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

3.64 kW

3.68 kW

COP Tj = +2°C

4.38

3.22

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

2.42 kW

2.47 kW

COP Tj = +7°C

5.89

4.21

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

1.03 kW

1.26 kW

COP Tj = 12°C

5.89

4.91

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

5.88 kW

5.83 kW

COP Tj = Tbiv

2.91

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.62 kW

5.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

9 W

9 W

PTO

6 W

6 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.70 kW

Annual energy consumption Qhe

3701 kWh

4203 kWh

Assure Mono 9
Configure model
Model name
Assure Mono 9
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.60 kW

8.60 kW

El input

1.87 kW

3.12 kW

COP

4.60

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

dB(A)

dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

126 %

Prated

8.00 kW

7.00 kW

SCOP

4.51

3.22

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.42 kW

6.58 kW

COP Tj = -7°C

2.80

1.87

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

4.83 kW

4.25 kW

COP Tj = +2°C

4.33

3.19

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.20 kW

2.80 kW

COP Tj = +7°C

6.20

4.38

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

1.55 kW

1.27 kW

COP Tj = 12°C

7.61

5.04

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

7.42 kW

6.58 kW

COP Tj = Tbiv

2.80

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.64 kW

5.53 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.51

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

9 W

9 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.80 kW

1.80 kW

Annual energy consumption Qhe

3844 kWh

4770 kWh