Certificate holders

Subtype

Samsung EHS TDM Plus R410A 9 kW 3Phase (space heating/ 260L)

Certificate Holder
Samsung Electronics Air Conditioner Europe B.V.
Evert van de Beekstraat 310
1118 CX Schiphol
Netherlands
Registration number
011-1W0376
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Samsung EHS TDM Plus R410A 9 kW 3Phase (space heating/ 260L)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

2,400 kg

Certification Date
29.07.2020
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 7
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

AE090MXTPGH/EU & AE260TNWTEH/EU
Configure model
Model name
AE090MXTPGH/EU & AE260TNWTEH/EU
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

7.66 kW

El input

2.12 kW

2.82 kW

COP

4.25

2.69

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

111 %

Prated

6.00 kW

5.00 kW

SCOP

4.44

2.86

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.00 kW

4.60 kW

COP Tj = -7°C

2.63

1.91

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

3.00 kW

2.80 kW

COP Tj = +2°C

4.47

2.78

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.20 kW

2.60 kW

COP Tj = +7°C

5.96

3.59

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.00 kW

2.50 kW

COP Tj = 12°C

8.27

4.72

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

5.60 kW

5.20 kW

COP Tj = Tbiv

2.31

1.68

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.60 kW

5.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.31

1.68

WTOL

55 °C

55 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2644 kWh

3871 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

105 %

COP

2.60

Heating up time

2:30 h:min

Standby power input

85.0 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

290 l