Certificate holders

Subtype

WPF 27

Certificate Holder
STIEBEL ELTRON GmbH & Co KG
Dr. Stiebel Straße 33
37603 Holzminden
Germany
Registration number
011-1W0276
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
WPF 27
Driving energy
Electricity
Heat Pump Type
Brine/Water
Refrigerant
R410A
Mass of Refrigerant

7,200 kg

Certification Date
24.01.2019
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 1

Models

WPF 27
Configure model
Model name
WPF 27
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

29.69 kW

26.69 kW

El input

6.12 kW

9.57 kW

COP

4.85

2.79

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

60 dB(A)

60 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

201 %

131 %

Prated

30.00 kW

27.00 kW

SCOP

5.23

3.48

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

29.70 kW

26.70 kW

COP Tj = +2°C

4.85

2.79

Pdh Tj = +7°C

30.00 kW

27.60 kW

COP Tj = +7°C

5.22

3.22

Pdh Tj = 12°C

30.50 kW

28.90 kW

COP Tj = 12°C

5.85

4.10

Pdh Tj = Tbiv

29.70 kW

26.70 kW

COP Tj = Tbiv

4.85

2.79

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

29.70 kW

26.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.85

2.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

0 W

0 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

74 W

74 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

7587 kWh

10292 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

60 dB(A)

60 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

213 %

139 %

Prated

37.00 kW

34.00 kW

SCOP

5.53

3.68

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

30.20 kW

28.00 kW

COP Tj = -7°C

5.51

3.47

Pdh Tj = +2°C

30.50 kW

28.70 kW

COP Tj = +2°C

5.83

3.92

Pdh Tj = +7°C

30.60 kW

29.20 kW

COP Tj = +7°C

6.09

4.36

Pdh Tj = 12°C

30.70 kW

29.60 kW

COP Tj = 12°C

6.13

4.73

Pdh Tj = Tbiv

30.10 kW

27.60 kW

COP Tj = Tbiv

5.38

3.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

29.70 kW

26.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.85

2.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

0 W

0 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

74 W

74 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

7.26 kW

7.13 kW

Annual energy consumption Qhe

1646 kWh

22680 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

60 dB(A)

60 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

132 %

Prated

30.00 kW

27.00 kW

SCOP

5.28

3.50

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

29.80 kW

27.00 kW

COP Tj = -7°C

4.92

2.92

Pdh Tj = +2°C

30.10 kW

28.00 kW

COP Tj = +2°C

5.31

3.49

Pdh Tj = +7°C

30.40 kW

28.70 kW

COP Tj = +7°C

5.71

3.93

Pdh Tj = 12°C

30.70 kW

29.30 kW

COP Tj = 12°C

6.16

4.47

Pdh Tj = Tbiv

29.70 kW

26.70 kW

COP Tj = Tbiv

4.85

2.79

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

29.70 kW

26.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.85

2.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

0 W

0 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

74 W

74 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

11619 kWh

15758 kWh