Certificate holders

Subtype

M thermal A Series 12 14 16kW with 240L tank

Certificate Holder
GD Midea Heating & Ventilating Equipment Co., Ltd.
Penglai Industry Road
528311 Beijiao, Shunde, Foshan
China
Registration number
041-K007-10 / 1
Certification Body
BRE Global Limited
Subtype title
M thermal A Series 12 14 16kW with 240L tank
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,840 kg

Certification Date
12.06.2020
Testing basis
Heat Pump Keymark Scheme Rules Rev 08
Generate PDF Export model CSV Download certificate
  • Number of models 6

Models

MHA-V12W/D2N8-B+HBT-A160/240C****GN8-B
Configure model
Model name
MHA-V12W/D2N8-B+HBT-A160/240C****GN8-B
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.00 kW

El input

2.44 kW

3.87 kW

COP

4.95

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

174 %

Prated

11.11 kW

12.51 kW

SCOP

6.53

4.43

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.11 kW

12.08 kW

COP Tj = +2°C

3.59

2.31

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.14 kW

8.04 kW

COP Tj = +7°C

5.87

3.86

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.56 kW

3.75 kW

COP Tj = 12°C

7.94

5.70

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.14 kW

8.04 kW

COP Tj = Tbiv

5.87

3.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.11 kW

12.08 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.59

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.44 kW

Annual energy consumption Qhe

2292 kWh

3776 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

118 %

Prated

11.38 kW

10.32 kW

SCOP

4.08

3.02

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.05 kW

6.63 kW

COP Tj = -7°C

3.48

2.63

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

4.68 kW

4.07 kW

COP Tj = +2°C

4.96

3.60

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.14 kW

2.78 kW

COP Tj = +7°C

6.10

4.54

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.57 kW

3.33 kW

COP Tj = 12°C

7.87

6.25

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

9.28 kW

8.42 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.01 kW

4.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.98

1.13

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.37 kW

6.12 kW

Annual energy consumption Qhe

6870 kWh

8419 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.28

8.42

COP Tj = -15°C (if TOL<-20°C)

2.59

1.84

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

189 %

135 %

Prated

12.00 kW

11.58 kW

SCOP

4.81

3.45

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.61 kW

10.25 kW

COP Tj = -7°C

2.88

2.01

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

6.69 kW

6.52 kW

COP Tj = +2°C

4.65

3.44

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.44 kW

4.36 kW

COP Tj = +7°C

6.62

4.59

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.74 kW

3.30 kW

COP Tj = 12°C

8.47

6.05

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

10.61 kW

10.25 kW

COP Tj = Tbiv

2.88

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.75 kW

9.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.79

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.26 kW

2.50 kW

Annual energy consumption Qhe

5152 kWh

6927 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

153 %

COP

3.73

Heating up time

1:33 h:min

Standby power input

30.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

92 %

COP

2.24

Heating up time

2:06 h:min

Standby power input

36.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.00

Heating up time

1:38 h:min

Standby power input

34.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l

MHA-V14W/D2N8-B+HBT-A160/240C****GN8-B
Configure model
Model name
MHA-V14W/D2N8-B+HBT-A160/240C****GN8-B
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.50 kW

13.80 kW

El input

3.09 kW

4.60 kW

COP

4.70

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

260 %

177 %

Prated

12.11 kW

13.74 kW

SCOP

6.63

4.49

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.04 kW

13.05 kW

COP Tj = +2°C

3.44

2.20

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

7.78 kW

8.83 kW

COP Tj = +7°C

5.84

3.91

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.75 kW

4.09 kW

COP Tj = 12°C

8.25

5.90

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

7.78 kW

8.83 kW

COP Tj = Tbiv

5.84

3.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.04 kW

13.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.44

2.20

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.07 kW

0.69 kW

Annual energy consumption Qhe

2457 kWh

4088 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

119 %

Prated

12.64 kW

10.97 kW

SCOP

4.07

3.05

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.97 kW

6.89 kW

COP Tj = -7°C

3.44

2.66

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.05 kW

4.32 kW

COP Tj = +2°C

4.92

3.66

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.16 kW

3.06 kW

COP Tj = +7°C

6.11

4.72

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.58 kW

3.33 kW

COP Tj = 12°C

7.82

6.25

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

10.31 kW

8.95 kW

COP Tj = Tbiv

2.53

1.79

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.57 kW

4.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.92

1.13

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.07 kW

6.77 kW

Annual energy consumption Qhe

7667 kWh

8866 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.31

8.95

COP Tj = -15°C (if TOL<-20°C)

2.53

1.79

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

136 %

Prated

13.73 kW

12.08 kW

SCOP

4.72

3.47

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.14 kW

10.69 kW

COP Tj = -7°C

2.79

2.01

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

7.95 kW

6.86 kW

COP Tj = +2°C

4.52

3.43

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

5.20 kW

4.64 kW

COP Tj = +7°C

6.68

4.66

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.76 kW

3.32 kW

COP Tj = 12°C

8.52

6.13

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

12.14 kW

10.69 kW

COP Tj = Tbiv

2.79

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.48 kW

9.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.76

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.23 kW

2.91 kW

Annual energy consumption Qhe

6012 kWh

7202 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

153 %

COP

3.73

Heating up time

1:33 h:min

Standby power input

30.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

92 %

COP

2.24

Heating up time

2:06 h:min

Standby power input

36.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.00

Heating up time

1:38 h:min

Standby power input

34.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l

MHA-V16W/D2N8-B+HBT-A160/240C****GN8-B
Configure model
Model name
MHA-V16W/D2N8-B+HBT-A160/240C****GN8-B
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.56 kW

5.52 kW

COP

4.50

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

249 %

176 %

Prated

13.09 kW

13.78 kW

SCOP

6.33

4.48

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.09 kW

13.38 kW

COP Tj = +2°C

3.35

2.29

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.42 kW

8.86 kW

COP Tj = +7°C

5.36

3.84

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.88 kW

4.06 kW

COP Tj = 12°C

8.11

5.86

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.42 kW

8.86 kW

COP Tj = Tbiv

5.36

3.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.09 kW

13.38 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.29

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.40 kW

Annual energy consumption Qhe

2781 kWh

4112 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

158 %

122 %

Prated

13.76 kW

11.79 kW

SCOP

4.02

3.12

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.31 kW

7.64 kW

COP Tj = -7°C

3.37

2.65

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.27 kW

4.43 kW

COP Tj = +2°C

4.86

3.79

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.62 kW

2.98 kW

COP Tj = +7°C

6.49

4.81

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.35 kW

3.43 kW

COP Tj = 12°C

7.40

6.29

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

11.22 kW

9.62 kW

COP Tj = Tbiv

2.43

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.89 kW

5.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.97

1.23

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.87 kW

6.57 kW

Annual energy consumption Qhe

8431 kWh

9309 kWh

Pdh Tj = -15°C (if TOL<-20°C)

11.22

9.62

COP Tj = -15°C (if TOL<-20°C)

2.43

1.86

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

182 %

133 %

Prated

15.21 kW

13.02 kW

SCOP

4.62

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.45 kW

11.52 kW

COP Tj = -7°C

2.72

1.99

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

8.57 kW

7.18 kW

COP Tj = +2°C

4.41

3.34

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

5.70 kW

4.68 kW

COP Tj = +7°C

6.56

4.61

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.78 kW

3.32 kW

COP Tj = 12°C

8.51

6.07

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

13.45 kW

11.52 kW

COP Tj = Tbiv

2.72

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.52 kW

10.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.48

1.80

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.68 kW

2.67 kW

Annual energy consumption Qhe

6804 kWh

7895 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

153 %

COP

3.73

Heating up time

1:33 h:min

Standby power input

30.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

92 %

COP

2.24

Heating up time

2:06 h:min

Standby power input

36.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.00

Heating up time

1:38 h:min

Standby power input

34.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l

MHA-V12W/D2RN8-B+HBT-A160/240C****GN8-B
Configure model
Model name
MHA-V12W/D2RN8-B+HBT-A160/240C****GN8-B
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.10 kW

12.00 kW

El input

2.44 kW

3.87 kW

COP

4.95

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

256 %

174 %

Prated

11.11 kW

12.51 kW

SCOP

6.53

4.42

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.11 kW

12.08 kW

COP Tj = +2°C

3.59

2.31

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.14 kW

8.04 kW

COP Tj = +7°C

5.87

3.86

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.56 kW

3.75 kW

COP Tj = 12°C

7.94

5.70

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.14 kW

8.04 kW

COP Tj = Tbiv

5.87

3.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.11 kW

12.08 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.59

2.31

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.44 kW

Annual energy consumption Qhe

2296 kWh

3780 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

118 %

Prated

11.38 kW

10.32 kW

SCOP

4.08

3.02

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.05 kW

6.63 kW

COP Tj = -7°C

3.48

2.63

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

4.68 kW

4.07 kW

COP Tj = +2°C

4.96

3.60

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.14 kW

2.78 kW

COP Tj = +7°C

6.10

4.54

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.57 kW

3.33 kW

COP Tj = 12°C

7.87

6.25

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

9.28 kW

8.42 kW

COP Tj = Tbiv

2.59

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.01 kW

4.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.98

1.13

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.37 kW

6.12 kW

Annual energy consumption Qhe

6871 kWh

8420 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.28

8.42

COP Tj = -15°C (if TOL<-20°C)

2.59

1.84

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

189 %

135 %

Prated

12.00 kW

11.58 kW

SCOP

4.81

3.45

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.61 kW

10.25 kW

COP Tj = -7°C

2.88

2.01

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

6.69 kW

6.52 kW

COP Tj = +2°C

4.65

3.44

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.44 kW

4.36 kW

COP Tj = +7°C

6.62

4.59

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.74 kW

3.30 kW

COP Tj = 12°C

8.47

6.05

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

10.61 kW

10.25 kW

COP Tj = Tbiv

2.88

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.75 kW

9.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.79

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.26 kW

2.50 kW

Annual energy consumption Qhe

5153 kWh

6928 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

153 %

COP

3.73

Heating up time

1:33 h:min

Standby power input

30.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

92 %

COP

2.24

Heating up time

2:06 h:min

Standby power input

36.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.00

Heating up time

1:38 h:min

Standby power input

34.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l

MHA-V14W/D2RN8-B+HBT-A160/240C****GN8-B
Configure model
Model name
MHA-V14W/D2RN8-B+HBT-A160/240C****GN8-B
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.50 kW

13.80 kW

El input

3.09 kW

4.60 kW

COP

4.70

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

260 %

176 %

Prated

12.11 kW

13.74 kW

SCOP

6.63

4.48

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.04 kW

13.05 kW

COP Tj = +2°C

3.44

2.20

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.78 kW

8.83 kW

COP Tj = +7°C

5.84

3.91

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.75 kW

4.09 kW

COP Tj = 12°C

8.25

5.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.78 kW

8.83 kW

COP Tj = Tbiv

5.84

3.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.04 kW

13.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.44

2.20

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.07 kW

0.69 kW

Annual energy consumption Qhe

2462 kWh

4092 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

119 %

Prated

12.64 kW

10.97 kW

SCOP

4.06

3.05

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22.00 °C

Pdh Tj = -7°C

7.97 kW

6.89 kW

COP Tj = -7°C

3.44

2.66

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.05 kW

4.32 kW

COP Tj = +2°C

4.92

3.66

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.16 kW

3.06 kW

COP Tj = +7°C

6.11

4.72

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.58 kW

3.33 kW

COP Tj = 12°C

7.82

6.25

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

10.31 kW

8.95 kW

COP Tj = Tbiv

2.53

1.79

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.57 kW

4.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.92

1.13

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.07 kW

6.77 kW

Annual energy consumption Qhe

7667.00 kWh

8867.00 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.31

8.95

COP Tj = -15°C (if TOL<-20°C)

2.53

1.79

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

65 dB(A)

65.00 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186.00 %

136 %

Prated

13.73 kW

12.08 kW

SCOP

4.72

3.47

Tbiv

-7 °C

-7 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

12.14 kW

10.69 kW

COP Tj = -7°C

2.79

2.01

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

7.95 kW

6.86 kW

COP Tj = +2°C

4.52

3.43

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

5.20 kW

4.64 kW

COP Tj = +7°C

6.68

4.66

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.76 kW

3.32 kW

COP Tj = 12°C

8.52

6.13

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

12.14 kW

10.69 kW

COP Tj = Tbiv

2.79

2.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.48 kW

9.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.76

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.23 kW

2.91 kW

Annual energy consumption Qhe

6013.00 kWh

7203 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

153 %

COP

3.73

Heating up time

1:33 h:min

Standby power input

30.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

92 %

COP

2.24

Heating up time

2:06 h:min

Standby power input

36.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.00

Heating up time

1:38 h:min

Standby power input

34.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l

MHA-V16W/D2RN8-B+HBT-A160/240C****GN8-B
Configure model
Model name
MHA-V16W/D2RN8-B+HBT-A160/240C****GN8-B
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.56 kW

5.52 kW

COP

4.50

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

248 %

176 %

Prated

13.09 kW

13.78 kW

SCOP

6.33

4.47

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.09 kW

13.38 kW

COP Tj = +2°C

3.35

2.29

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

8.42 kW

8.86 kW

COP Tj = +7°C

5.36

3.84

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.88 kW

4.06 kW

COP Tj = 12°C

8.11

5.86

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.42 kW

8.86 kW

COP Tj = Tbiv

5.36

3.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.09 kW

13.38 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.29

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.40 kW

Annual energy consumption Qhe

2786 kWh

4116 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

158 %

122 %

Prated

13.76 kW

11.79 kW

SCOP

4.02

3.12

Tbiv

-15 °C

-15 °C

TOL

-22.00 °C

-22.00 °C

Pdh Tj = -7°C

8.31 kW

7.64 kW

COP Tj = -7°C

3.37

2.65

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.27 kW

4.43 kW

COP Tj = +2°C

4.86

3.79

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.62 kW

2.98 kW

COP Tj = +7°C

6.49

4.81

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.35 kW

3.43 kW

COP Tj = 12°C

7.40

6.29

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

11.22 kW

9.62 kW

COP Tj = Tbiv

2.43

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.89 kW

5.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.97

1.23

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.87 kW

6.57 kW

Annual energy consumption Qhe

8431 kWh

9310 kWh

Pdh Tj = -15°C (if TOL<-20°C)

11.22

9.62

COP Tj = -15°C (if TOL<-20°C)

2.43

1.86

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

182 %

133 %

Prated

15.21 kW

13.02 kW

SCOP

4.62

3.41

Tbiv

-7.00 °C

-7.00 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

13.45 kW

11.52 kW

COP Tj = -7°C

2.72

1.99

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

8.57 kW

7.18 kW

COP Tj = +2°C

4.41

3.34

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

5.70 kW

4.68 kW

COP Tj = +7°C

6.56

4.61

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.78 kW

3.32 kW

COP Tj = 12°C

8.51

6.07

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

13.45 kW

11.52 kW

COP Tj = Tbiv

2.72

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.52 kW

10.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.48

1.80

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0.00 W

0.00 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.68 kW

2.67 kW

Annual energy consumption Qhe

6805.00 kWh

7896 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

153 %

COP

3.73

Heating up time

1:33 h:min

Standby power input

30.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

92 %

COP

2.24

Heating up time

2:06 h:min

Standby power input

36.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.00

Heating up time

1:38 h:min

Standby power input

34.0 W

Reference hot water temperature

48.5 °C

Mixed water at 40°C

280 l