Certificate holders

Subtype

M thermal A series 18 22 26 30 kW

Certificate Holder
GD Midea Heating & Ventilating Equipment Co., Ltd.
Penglai Industry Road
528311 Beijiao, Shunde, Foshan
China
Registration number
041-K007-11 / 1
Certification Body
BRE Global Limited
Subtype title
M thermal A series 18 22 26 30 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

5,000 kg

Certification Date
02.12.2020
Testing basis
HP Keymark Scheme Rules Rev 08
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

MHC-V18W/D2RN8
Configure model
Model name
MHC-V18W/D2RN8
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

18.32 kW

18.10 kW

El input

3.96 kW

6.63 kW

COP

4.63

2.73

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

71 dB(A)

71 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

226 %

157 %

Prated

17.67 kW

18.07 kW

SCOP

5.74

4.00

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

17.67 kW

18.07 kW

COP Tj = +2°C

3.53

2.12

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

11.36 kW

11.62 kW

COP Tj = +7°C

5.16

3.49

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.45 kW

5.35 kW

COP Tj = 12°C

7.01

5.09

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.36 kW

11.62 kW

COP Tj = Tbiv

5.16

3.49

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.67 kW

18.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.53

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4116 kWh

6041 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

71 dB(A)

71 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

146 %

97 %

Prated

17.76 kW

18.38 kW

SCOP

3.73

2.50

Tbiv

-15 °C

-7 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

11.21 kW

11.13 kW

COP Tj = -7°C

3.09

1.98

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

6.64 kW

6.65 kW

COP Tj = +2°C

4.50

3.44

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.77 kW

4.66 kW

COP Tj = +7°C

5.85

4.35

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.95 kW

3.74 kW

COP Tj = 12°C

7.18

5.68

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

14.49 kW

11.13 kW

COP Tj = Tbiv

2.42

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.14 kW

13.56 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.67

1.21

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.62 kW

18.38 kW

Annual energy consumption Qhe

11740 kWh

18156 kWh

Pdh Tj = -15°C (if TOL<-20°C)

14.49

13.56

COP Tj = -15°C (if TOL<-20°C)

2.42

1.21

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

71 dB(A)

71 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

125 %

Prated

17.99 kW

17.67 kW

SCOP

4.60

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

15.90 kW

15.61 kW

COP Tj = -7°C

2.85

1.72

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

9.66 kW

9.59 kW

COP Tj = +2°C

4.59

3.32

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.56 kW

6.37 kW

COP Tj = +7°C

5.99

4.48

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.76 kW

3.57 kW

COP Tj = 12°C

7.08

5.27

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

15.90 kW

15.61 kW

COP Tj = Tbiv

2.85

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.99 kW

15.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.49

1.17

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

2.64 kW

Annual energy consumption Qhe

8086 kWh

11375 kWh

MHC-V22W/D2RN8
Configure model
Model name
MHC-V22W/D2RN8
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

22.30 kW

22.10 kW

El input

5.13 kW

8.33 kW

COP

4.35

2.65

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

73 dB(A)

73 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

234 %

161 %

Prated

21.90 kW

22.01 kW

SCOP

5.85

4.09

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

21.81 kW

22.01 kW

COP Tj = +2°C

3.31

2.12

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

14.08 kW

14.15 kW

COP Tj = +7°C

5.20

3.50

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.44 kW

6.38 kW

COP Tj = 12°C

7.50

5.34

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

14.08 kW

14.15 kW

COP Tj = Tbiv

5.20

3.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

21.81 kW

22.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.31

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.09 kW

0.00 kW

Annual energy consumption Qhe

4945 kWh

7180 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

73 dB(A)

73 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

146 %

102 %

Prated

21.40 kW

22.36 kW

SCOP

3.72

2.62

Tbiv

-15 °C

-7 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

13.30 kW

13.53 kW

COP Tj = -7°C

3.12

2.07

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

8.25 kW

8.61 kW

COP Tj = +2°C

4.42

3.70

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

5.45 kW

5.21 kW

COP Tj = +7°C

5.87

4.49

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.98 kW

3.74 kW

COP Tj = 12°C

7.19

5.76

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

17.46 kW

13.53 kW

COP Tj = Tbiv

2.36

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.27 kW

13.78 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.69

1.24

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

8.13 kW

22.36 kW

Annual energy consumption Qhe

14179 kWh

21067 kWh

Pdh Tj = -15°C (if TOL<-20°C)

17.46

13.78

COP Tj = -15°C (if TOL<-20°C)

2.36

1.24

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

73 dB(A)

73 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

126 %

Prated

22.31 kW

22.43 kW

SCOP

4.53

3.22

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

19.72 kW

19.82 kW

COP Tj = -7°C

2.74

1.74

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

12.03 kW

11.89 kW

COP Tj = +2°C

4.41

3.32

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

8.00 kW

7.97 kW

COP Tj = +7°C

6.29

4.66

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

3.79 kW

3.60 kW

COP Tj = 12°C

7.14

5.32

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

19.72 kW

19.82 kW

COP Tj = Tbiv

2.74

1.74

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

20.33 kW

13.81 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.35

1.08

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.97 kW

8.60 kW

Annual energy consumption Qhe

10180 kWh

14390 kWh

MHC-V26W/D2RN8
Configure model
Model name
MHC-V26W/D2RN8
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

26.30 kW

26.06 kW

El input

6.50 kW

10.72 kW

COP

4.05

2.43

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

75 dB(A)

75 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

231 %

168 %

Prated

26.08 kW

26.22 kW

SCOP

5.85

4.26

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

25.50 kW

26.22 kW

COP Tj = +2°C

3.00

1.99

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

16.77 kW

16.86 kW

COP Tj = +7°C

5.02

3.47

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.65 kW

7.58 kW

COP Tj = 12°C

7.78

5.94

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

16.77 kW

16.86 kW

COP Tj = Tbiv

5.02

3.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

25.50 kW

26.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.00

1.99

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.58 kW

0.00 kW

Annual energy consumption Qhe

5959 kWh

8218 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

75 dB(A)

75 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

143 %

101 %

Prated

25.75 kW

26.27 kW

SCOP

3.64

2.59

Tbiv

-12 °C

-7 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

15.91 kW

15.90 kW

COP Tj = -7°C

3.10

2.10

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

10.10 kW

10.17 kW

COP Tj = +2°C

4.45

3.58

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

6.30 kW

6.52 kW

COP Tj = +7°C

6.06

4.99

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.03 kW

3.63 kW

COP Tj = 12°C

7.13

5.68

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

18.97 kW

15.90 kW

COP Tj = Tbiv

2.36

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.07 kW

13.37 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.67

1.20

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

12.68 kW

26.27 kW

Annual energy consumption Qhe

17421 kWh

24967 kWh

Pdh Tj = -15°C (if TOL<-20°C)

18.95

13.37

COP Tj = -15°C (if TOL<-20°C)

2.27

1.20

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

75 dB(A)

75 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

123 %

Prated

25.04 kW

26.15 kW

SCOP

4.50

3.14

Tbiv

-7 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

22.12 kW

20.64 kW

COP Tj = -7°C

2.57

1.69

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

13.76 kW

14.26 kW

COP Tj = +2°C

4.44

3.12

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

9.36 kW

9.29 kW

COP Tj = +7°C

6.52

4.74

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.09 kW

3.89 kW

COP Tj = 12°C

7.35

5.48

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

22.12 kW

22.11 kW

COP Tj = Tbiv

2.57

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

20.33 kW

13.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.35

1.08

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.68 kW

12.28 kW

Annual energy consumption Qhe

11489 kWh

17204 kWh

MHC-V30W/D2RN8
Configure model
Model name
MHC-V30W/D2RN8
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

29.93 kW

29.68 kW

El input

8.02 kW

12.97 kW

COP

3.73

2.29

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

77 dB(A)

77 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

213 %

163 %

Prated

30.44 kW

29.73 kW

SCOP

5.39

4.15

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

26.29 kW

26.41 kW

COP Tj = +2°C

2.94

1.99

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

19.57 kW

19.11 kW

COP Tj = +7°C

4.75

3.37

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

8.90 kW

8.92 kW

COP Tj = 12°C

7.53

6.09

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

19.57 kW

19.11 kW

COP Tj = Tbiv

4.75

3.37

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

26.29 kW

26.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.94

1.99

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.15 kW

3.32 kW

Annual energy consumption Qhe

7540 kWh

9580 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

77 dB(A)

77 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

138 %

100 %

Prated

29.13 kW

30.41 kW

SCOP

3.52

2.56

Tbiv

-10 °C

-7 °C

TOL

-22 °C

-15 °C

Pdh Tj = -7°C

18.49 kW

18.40 kW

COP Tj = -7°C

3.07

2.10

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

11.88 kW

11.22 kW

COP Tj = +2°C

4.42

3.51

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

7.53 kW

7.42 kW

COP Tj = +7°C

6.15

5.18

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.11 kW

3.64 kW

COP Tj = 12°C

6.87

5.73

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

19.93 kW

18.40 kW

COP Tj = Tbiv

2.44

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.17 kW

13.06 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.67

1.18

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

15.96 kW

30.41 kW

Annual energy consumption Qhe

20390 kWh

29238 kWh

Pdh Tj = -15°C (if TOL<-20°C)

18.61

13.06

COP Tj = -15°C (if TOL<-20°C)

2.24

1.18

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

77 dB(A)

77 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

123 %

Prated

29.18 kW

29.69 kW

SCOP

4.19

3.14

Tbiv

-5 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

21.90 kW

20.11 kW

COP Tj = -7°C

2.54

1.63

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

16.16 kW

16.49 kW

COP Tj = +2°C

4.16

3.09

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

10.64 kW

10.50 kW

COP Tj = +7°C

6.38

4.75

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.54 kW

4.64 kW

COP Tj = 12°C

7.72

5.91

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

23.51 kW

23.97 kW

COP Tj = Tbiv

2.71

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

20.37 kW

13.82 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.35

1.07

WTOL

60 °C

60 °C

Poff

18 W

18 W

PTO

96 W

96 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

8.75 kW

15.86 kW

Annual energy consumption Qhe

14165 kWh

19316.17 kWh