2,100 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
12.68 kW
11.58 kW
El input
2.71 kW
4.07 kW
COP
4.68
2.84
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
47 dB(A)
47 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
150 %
Prated
25.00 kW
25.00 kW
SCOP
5.21
3.95
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
22.01 kW
21.71 kW
COP Tj = -7°C
4.24
2.98
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
13.77 kW
13.74 kW
COP Tj = +2°C
5.31
4.00
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
8.88 kW
8.44 kW
COP Tj = +7°C
5.77
4.55
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
7.52 kW
7.42 kW
COP Tj = 12°C
5.79
4.72
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
24.19 kW
23.86 kW
COP Tj = Tbiv
4.09
2.76
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
24.19 kW
23.86 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.09
2.76
WTOL
65 °C
65 °C
Poff
16 W
16 W
PTO
0 W
0 W
PSB
22 W
22 W
PCK
8 W
8 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
9913 kWh
13063 kWh
Water/Water Heat Pump
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.94 kW
15.19 kW
El input
2.67 kW
4.12 kW
COP
6.34
3.69
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
47 dB(A)
47 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
285 %
197 %
Prated
34.00 kW
31.00 kW
SCOP
7.32
5.14
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
30.08 kW
27.60 kW
COP Tj = -7°C
5.40
3.60
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
18.30 kW
16.90 kW
COP Tj = +2°C
7.50
5.10
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
11.80 kW
10.90 kW
COP Tj = +7°C
8.50
6.36
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
8.60 kW
8.30 kW
COP Tj = 12°C
8.70
6.60
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
34.00 kW
31.00 kW
COP Tj = Tbiv
5.10
3.42
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
34.00 kW
31.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.10
3.42
WTOL
65 °C
65 °C
Poff
16 W
16 W
PTO
30 W
20 W
PSB
22 W
22 W
PCK
8 W
8 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
9598 kWh
12469 kWh