Certificate holders

Subtype

i-SHWAK V4 08

Certificate Holder
Advantix S.p.A.
Via San Giuseppe Lavoratore, 24
37040 Arcole Verona
Italy
Registration number
ICIM-PDC-000077-00
Certification Body
ICIM S.p.A.
Subtype title
i-SHWAK V4 08
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

2,200 kg

Certification Date
26.05.2020
Testing basis
HP KEYMARK certification scheme rules rev. no. 7
Phase-out Date
21.07.2024
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

i-SHWAK V4 08 Phasing out on 21.07.2024
Configure model
Model name
i-SHWAK V4 08
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz
Phase-out Date
21.07.2024

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.01 kW

6.89 kW

El input

1.89 kW

3.09 kW

COP

4.24

2.23

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

2.11 kW

Cooling capacity

6.12

EER

2.90

EN 14825

+7°C/+12°C

Pdesignc

6.12 kW

SEER

3.84

Pdc Tj = 35°C

6.12 kW

EER Tj = 35°C

2.90

Pdc Tj = 30°C

4.51 kW

EER Tj = 30°C

3.88

Cdc Tj = 30 °C

1.0

Pdc Tj = 25°C

3.40 kW

EER Tj = 25°C

4.09

Cdc Tj = 25 °C

1.0

Pdc Tj = 20°C

3.68 kW

EER Tj = 20°C

4.92

Cdc Tj = 20 °C

1.0

Poff

12 W

PTO

0 W

PSB

12 W

PCK

0 W

Annual energy consumption Qce

558 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

155 %

124 %

Prated

6.00 kW

5.00 kW

SCOP

3.94

3.17

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.50 kW

5.00 kW

COP Tj = -7°C

2.62

1.72

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

3.40 kW

3.30 kW

COP Tj = +2°C

4.19

3.10

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

3.60 kW

4.00 kW

COP Tj = +7°C

4.39

4.42

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

3.70 kW

4.40 kW

COP Tj = 12°C

5.12

6.18

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

5.50 kW

5.00 kW

COP Tj = Tbiv

2.62

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.10 kW

4.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.33

1.44

WTOL

39 °C

39 °C

Poff

0 W

0 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2216 kWh

2493 kWh