Certificate holders

Subtype

i-SHWAK V4 06

Certificate Holder
Advantix S.p.A.
Via San Giuseppe Lavoratore, 24
37040 Arcole Verona
Italy
Registration number
ICIM-PDC-000076-00
Certification Body
ICIM S.p.A.
Subtype title
i-SHWAK V4 06
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

2,680 kg

Certification Date
26.05.2020
Testing basis
HP KEYMARK certification scheme rules rev. no. 7
Phase-out Date
21.07.2024
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

i-SHWAK V4 06 Phasing out on 21.07.2024
Configure model
Model name
i-SHWAK V4 06
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
1x230V 50Hz
Phase-out Date
21.07.2024

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.57 kW

5.64 kW

El input

1.50 kW

2.32 kW

COP

4.38

2.43

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.74 kW

Cooling capacity

5.07

EER

2.91

EN 14825

+7°C/+12°C

Pdesignc

5.07 kW

SEER

3.82

Pdc Tj = 35°C

5.07 kW

EER Tj = 35°C

2.91

Pdc Tj = 30°C

3.74 kW

EER Tj = 30°C

4.04

Cdc Tj = 30 °C

1.0

Pdc Tj = 25°C

3.40 kW

EER Tj = 25°C

4.09

Cdc Tj = 25 °C

1.0

Pdc Tj = 20°C

3.68 kW

EER Tj = 20°C

4.92

Cdc Tj = 20 °C

1.0

Poff

12 W

PTO

0 W

PSB

12 W

PCK

0 W

Annual energy consumption Qce

464 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

151 %

119 %

Prated

5.00 kW

4.00 kW

SCOP

3.86

3.06

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.30 kW

4.50 kW

COP Tj = -7°C

2.68

1.57

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

3.40 kW

2.70 kW

COP Tj = +2°C

4.10

2.95

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

3.60 kW

3.30 kW

COP Tj = +7°C

4.15

4.57

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

3.70 kW

3.60 kW

COP Tj = 12°C

5.11

6.02

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

5.30 kW

4.50 kW

COP Tj = Tbiv

2.68

1.57

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.34

1.45

WTOL

39 °C

39 °C

Poff

0 W

0 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2171 kWh

2329 kWh