Certificate holders

Subtype

TERRA 11 HPLB

Certificate Holder
Ochsner Wärmepumpen GmbH
Krackowizerstraße 4
4020 Linz
Austria
Registration number
011-1W0419
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TERRA 11 HPLB
Driving energy
Electricity
Heat Pump Type
Brine/Water
Refrigerant
R410A
Mass of Refrigerant

2,130 kg

Certification Date
30.09.2020
Testing basis
HP KEYMARK certification scheme rules rev. 7
Generate PDF Export model CSV
  • Number of models 2

Models

TERRA 11 HPLB, average
Configure model
Model name
TERRA 11 HPLB, average
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.30 kW

9.40 kW

El input

2.17 kW

3.24 kW

COP

4.75

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

0 dB(A)

0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

10.00 kW

9.00 kW

SCOP

5.21

3.61

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.30 kW

9.50 kW

COP Tj = -7°C

4.81

3.03

Pdh Tj = +2°C

10.40 kW

9.80 kW

COP Tj = +2°C

5.14

3.55

Pdh Tj = +7°C

10.50 kW

10.00 kW

COP Tj = +7°C

5.47

3.95

Pdh Tj = 12°C

10.60 kW

10.20 kW

COP Tj = 12°C

5.84

4.43

Pdh Tj = Tbiv

10.30 kW

9.40 kW

COP Tj = Tbiv

4.75

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.30 kW

9.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.75

2.90

Rated airflow rate

0 m³/h

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

60 °C

60 °C

Poff

0 W

0 W

PTO

85 W

85 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4091 kWh

5358 kWh

TERRA 11 HPLB, all climates, low temperature
Configure model
Model name
TERRA 11 HPLB, all climates, low temperature
Application
Heating (low temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Heat output

10.31 kW

El input

2.17 kW

COP

4.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Sound power level indoor

50 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

199 %

Prated

10.00 kW

SCOP

4.91

Tbiv

2 °C

TOL

2 °C

Pdh Tj = -7°C

0.00 kW

COP Tj = -7°C

0.00

Pdh Tj = +2°C

10.30 kW

COP Tj = +2°C

4.75

Pdh Tj = +7°C

10.40 kW

COP Tj = +7°C

5.07

Pdh Tj = 12°C

10.60 kW

COP Tj = 12°C

5.59

Pdh Tj = Tbiv

10.30 kW

COP Tj = Tbiv

4.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.75

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

60 °C

Poff

0 W

PTO

85 W

PSB

10 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

2660 kWh

Colder Climate

EN 12102-1

Sound power level indoor

50 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

206 %

Prated

13.00 kW

SCOP

5.10

Tbiv

-15 °C

TOL

-22 °C

Pdh Tj = -7°C

10.50 kW

COP Tj = -7°C

5.31

Pdh Tj = +2°C

10.60 kW

COP Tj = +2°C

5.57

Pdh Tj = +7°C

10.60 kW

COP Tj = +7°C

5.78

Pdh Tj = 12°C

10.60 kW

COP Tj = 12°C

5.82

Pdh Tj = Tbiv

10.50 kW

COP Tj = Tbiv

5.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.20

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

60 °C

Poff

0 W

PTO

85 W

PSB

10 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

2.50 kW

Annual energy consumption Qhe

5895 kWh

Average Climate

EN 12102-1

Sound power level indoor

50 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

200 %

Prated

10.00 kW

SCOP

5.21

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

10.30 kW

COP Tj = -7°C

4.81

Pdh Tj = +2°C

10.40 kW

COP Tj = +2°C

5.14

Pdh Tj = +7°C

10.50 kW

COP Tj = +7°C

5.47

Pdh Tj = 12°C

10.60 kW

COP Tj = 12°C

5.84

Pdh Tj = Tbiv

10.30 kW

COP Tj = Tbiv

4.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.75

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

60 °C

Poff

0 W

PTO

85 W

PSB

10 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

4091 kWh