Certificate holders

Subtype

TERRA 6 HPLA

Certificate Holder
Ochsner Wärmepumpen GmbH
Krackowizerstraße 4
4020 Linz
Austria
Registration number
011-1W0414
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TERRA 6 HPLA
Driving energy
Electricity
Heat Pump Type
Brine/Water
Refrigerant
R410A
Mass of Refrigerant

1,400 kg

Certification Date
30.09.2020
Testing basis
HP KEYMARK certification scheme rules rev. 7
Generate PDF Export model CSV
  • Number of models 2

Models

TERRA 6 HPLA , average climate
Configure model
Model name
TERRA 6 HPLA , average climate
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.82 kW

5.19 kW

El input

1.21 kW

1.85 kW

COP

4.80

2.81

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

0 dB(A)

0 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

134 %

Prated

6.00 kW

5.00 kW

SCOP

5.32

3.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.80 kW

5.30 kW

COP Tj = -7°C

4.87

2.94

Pdh Tj = +2°C

5.90 kW

5.50 kW

COP Tj = +2°C

5.24

3.49

Pdh Tj = +7°C

6.00 kW

5.60 kW

COP Tj = +7°C

5.61

3.92

Pdh Tj = 12°C

6.00 kW

5.70 kW

COP Tj = 12°C

6.03

4.44

Pdh Tj = Tbiv

5.80 kW

5.20 kW

COP Tj = Tbiv

4.81

2.81

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.80 kW

5.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.81

2.81

Rated airflow rate

0 m³/h

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

54 W

54 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2262 kWh

3017 kWh

TERRA 6 HPLA, low temperature, all climates
Configure model
Model name
TERRA 6 HPLA, low temperature, all climates
Application
Heating (low temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

5.82 kW

El input

1.21 kW

COP

4.80

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Sound power level indoor

43 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

203 %

Prated

6.00 kW

SCOP

5.28

Tbiv

2 °C

TOL

0 °C

Pdh Tj = -7°C

0.00 kW

COP Tj = -7°C

0.00

Pdh Tj = +2°C

5.80 kW

COP Tj = +2°C

4.81

Pdh Tj = +7°C

5.90 kW

COP Tj = +7°C

5.16

Pdh Tj = 12°C

6.00 kW

COP Tj = 12°C

5.75

Pdh Tj = Tbiv

5.80 kW

COP Tj = Tbiv

4.81

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.81

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

1473 kWh

Colder Climate

EN 12102-1

Sound power level indoor

43 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

212 %

Prated

7.00 kW

SCOP

5.49

Tbiv

-15 °C

TOL

-22 °C

Pdh Tj = -7°C

5.90 kW

COP Tj = -7°C

5.43

Pdh Tj = +2°C

6.00 kW

COP Tj = +2°C

5.72

Pdh Tj = +7°C

6.00 kW

COP Tj = +7°C

5.97

Pdh Tj = 12°C

6.00 kW

COP Tj = 12°C

6.01

Pdh Tj = Tbiv

5.90 kW

COP Tj = Tbiv

5.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.31

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

1.43 kW

Annual energy consumption Qhe

3254 kWh

Average Climate

EN 12102-1

Sound power level indoor

43 dB(A)

Sound power level outdoor

0 dB(A)

EN 14825

ηs

205 %

Prated

6.00 kW

SCOP

5.32

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

5.80 kW

COP Tj = -7°C

4.87

Pdh Tj = +2°C

5.90 kW

COP Tj = +2°C

5.24

Pdh Tj = +7°C

6.00 kW

COP Tj = +7°C

5.61

Pdh Tj = 12°C

6.00 kW

COP Tj = 12°C

6.03

Pdh Tj = Tbiv

5.80 kW

COP Tj = Tbiv

4.81

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.81

Rated airflow rate

0 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

2262 kWh