AUREA 5 R32

Certificate Holder
Groupe Atlantic
44 boulevard des Etats-Unis
85000 La Roche Sur Yon
France
Registration number
012-C700073
Certification Body
RISE CERT
Subtype title
AUREA 5 R32
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

0,800 kg

Certification Date
27.05.2020
Testing basis
HP Keymark Scheme Rules rev 7
Phase-out Date
09.04.2026
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

AUREA 5 R32 Phasing out on 09.04.2026
Configure model
Model name
AUREA 5 R32
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
09.04.2026

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.30 kW

4.90 kW

El input

1.14 kW

1.73 kW

COP

4.62

2.83

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

127 %

Prated

5.00 kW

5.00 kW

SCOP

4.64

3.26

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.10 kW

4.20 kW

COP Tj = -7°C

2.86

1.94

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

2.50 kW

2.50 kW

COP Tj = +2°C

4.86

3.41

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

1.60 kW

1.60 kW

COP Tj = +7°C

6.34

4.31

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

1.50 kW

1.20 kW

COP Tj = 12°C

8.15

5.27

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

4.10 kW

4.20 kW

COP Tj = Tbiv

2.86

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.80 kW

4.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.62

1.77

WTOL

55 °C

55 °C

Poff

17 W

17 W

PTO

105 W

105 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.80 kW

0.60 kW

Annual energy consumption Qhe

2046 kWh

2978 kWh