Certificate holders

Subtype

L6 Split

Certificate Holder
ait-deutschland GmbH
Industriestr. 3
95359 Kasendorf
Germany
Registration number
012-C700070 / Issue 2
Certification Body
RISE CERT
Subtype title
L6 Split
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,500 kg

Certification Date
29.04.2020
Testing basis
HP Keymark Scheme 2018
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

alpha innotec L6 Split-HT 6
Configure model
Model name
alpha innotec L6 Split-HT 6
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.42 kW

1.57 kW

El input

0.50 kW

0.76 kW

COP

4.85

2.06

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

131 %

Prated

4.80 kW

5.30 kW

SCOP

4.77

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.30 kW

4.70 kW

COP Tj = -7°C

2.60

1.88

Pdh Tj = +2°C

2.60 kW

2.80 kW

COP Tj = +2°C

4.84

3.26

Pdh Tj = +7°C

1.70 kW

1.80 kW

COP Tj = +7°C

6.91

4.72

Pdh Tj = 12°C

2.70 kW

2.70 kW

COP Tj = 12°C

7.72

6.47

Pdh Tj = Tbiv

4.30 kW

4.70 kW

COP Tj = Tbiv

2.60

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.20 kW

4.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.24

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.20 kW

Annual energy consumption Qhe

2089 kWh

3248 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

91 %

COP

2.22

Heating up time

01:40 h:min

Standby power input

45.0 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

230 l

NOVELAN L6 Split-CS 6
Configure model
Model name
NOVELAN L6 Split-CS 6
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.42 kW

1.57 kW

El input

0.50 kW

0.76 kW

COP

4.85

2.06

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

131 %

Prated

4.80 kW

5.30 kW

SCOP

4.77

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.30 kW

4.70 kW

COP Tj = -7°C

2.60

1.88

Pdh Tj = +2°C

2.60 kW

2.80 kW

COP Tj = +2°C

4.84

3.26

Pdh Tj = +7°C

1.70 kW

1.80 kW

COP Tj = +7°C

6.91

4.72

Pdh Tj = 12°C

2.70 kW

2.70 kW

COP Tj = 12°C

7.72

6.47

Pdh Tj = Tbiv

4.30 kW

4.70 kW

COP Tj = Tbiv

2.60

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.20 kW

4.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.24

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.20 kW

Annual energy consumption Qhe

2089 kWh

3248 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

91 %

COP

2.22

Heating up time

01:40 h:min

Standby power input

45.0 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

230 l

alpha innotec L6 Split-HM 6
Configure model
Model name
alpha innotec L6 Split-HM 6
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.42 kW

1.57 kW

El input

0.50 kW

0.76 kW

COP

4.85

2.06

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

131 %

Prated

4.80 kW

5.30 kW

SCOP

4.77

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.30 kW

4.70 kW

COP Tj = -7°C

2.60

1.88

Pdh Tj = +2°C

2.60 kW

2.80 kW

COP Tj = +2°C

4.84

3.26

Pdh Tj = +7°C

1.70 kW

1.80 kW

COP Tj = +7°C

6.91

4.72

Pdh Tj = 12°C

2.70 kW

2.70 kW

COP Tj = 12°C

7.72

6.47

Pdh Tj = Tbiv

4.30 kW

4.70 kW

COP Tj = Tbiv

2.60

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.20 kW

4.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.24

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.20 kW

Annual energy consumption Qhe

2089 kWh

3248 kWh

NOVELAN L6 Split-HV 6
Configure model
Model name
NOVELAN L6 Split-HV 6
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

2.42 kW

1.57 kW

El input

0.50 kW

0.76 kW

COP

4.85

2.06

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

131 %

Prated

4.80 kW

5.30 kW

SCOP

4.77

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.30 kW

4.70 kW

COP Tj = -7°C

2.60

1.88

Pdh Tj = +2°C

2.60 kW

2.80 kW

COP Tj = +2°C

4.84

3.26

Pdh Tj = +7°C

1.70 kW

1.80 kW

COP Tj = +7°C

6.91

4.72

Pdh Tj = 12°C

2.70 kW

2.70 kW

COP Tj = 12°C

7.72

6.47

Pdh Tj = Tbiv

4.30 kW

4.70 kW

COP Tj = Tbiv

2.60

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.20 kW

4.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.24

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.20 kW

Annual energy consumption Qhe

2089 kWh

3248 kWh