0,970 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.50 kW
5.50 kW
El input
1.18 kW
2.06 kW
COP
4.65
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
57 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
125 %
Prated
6.00 kW
5.00 kW
SCOP
4.46
3.21
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.00 kW
4.70 kW
COP Tj = -7°C
2.74
1.97
Cdh Tj = -7 °C
0.96
0.97
Pdh Tj = +2°C
3.00 kW
2.90 kW
COP Tj = +2°C
4.68
3.11
Cdh Tj = +2 °C
0.96
0.97
Pdh Tj = +7°C
2.10 kW
1.80 kW
COP Tj = +7°C
6.04
4.29
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.40 kW
2.30 kW
COP Tj = 12°C
7.43
6.06
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
5.00 kW
4.70 kW
COP Tj = Tbiv
2.74
1.97
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.50 kW
4.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.67
1.73
WTOL
55 °C
55 °C
Poff
4 W
4 W
PTO
12 W
13 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.10 kW
1.30 kW
Annual energy consumption Qhe
2594 kWh
3411 kWh