Certificate holders

Subtype

DAIKIN ALTHERMA 3 H HT 16KW (300L)

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Reg. No.
011-1W0359
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA 3 H HT 16KW (300L)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass Of Refrigerant

4,200 kg

Certification Date
07.02.2020
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 8

Models

EPRA16DV / ETSH16P30D
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

7.24 kW

El input

1.80 kW

2.41 kW

COP

5.00

3.01

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

13.00 kW

13.00 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.10 kW

11.20 kW

COP Tj = -7°C

3.12

2.47

Cdh

1.00

1.00

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.44

3.56

Cdh

1.00

1.00

Pdh Tj = +7°C

5.70 kW

6.90 kW

COP Tj = +7°C

5.84

4.44

Cdh

1.00

1.00

Pdh Tj = 12°C

6.00 kW

6.20 kW

COP Tj = 12°C

7.40

5.72

Cdh

1.00

1.00

Pdh Tj = Tbiv

11.10 kW

12.20 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.10 kW

12.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electrical

electrical

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

101 %

COP

2.38

Heating up time

1:41 h:min

Standby power input

49.0 W

Reference hot water temperature

47.0 °C

Mixed water at 40°C

149 l

EPRA16DV / ETSHB16P30D
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

7.24 kW

El input

1.80 kW

2.41 kW

COP

5.00

3.01

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

140 %

Prated

13.00 kW

13.00 kW

SCOP

4.51

3.58

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.10 kW

11.20 kW

COP Tj = -7°C

3.12

2.47

Cdh

1.00

1.00

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.44

3.56

Cdh

1.00

1.00

Pdh Tj = +7°C

5.70 kW

6.90 kW

COP Tj = +7°C

5.84

4.44

Cdh

1.00

1.00

Pdh Tj = 12°C

6.00 kW

6.20 kW

COP Tj = 12°C

7.40

5.72

Cdh

1.00

1.00

Pdh Tj = Tbiv

11.10 kW

12.20 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.10 kW

12.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electrical

electrical

Supplementary Heater: PSUP

9.00 kW

9.00 kW

Annual energy consumption Qhe

5726 kWh

7211 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

101 %

COP

2.38

Heating up time

1:41 h:min

Standby power input

49.0 W

Reference hot water temperature

47.0 °C

Mixed water at 40°C

149 l

EPRA16DW / ETSH16P30D
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

7.24 kW

El input

1.80 kW

2.47 kW

COP

5.00

2.93

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

140 %

Prated

13.00 kW

13.00 kW

SCOP

4.48

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.72 kW

11.10 kW

COP Tj = -7°C

2.97

2.43

Cdh

1.00

1.00

Pdh Tj = +2°C

6.87 kW

6.70 kW

COP Tj = +2°C

4.94

3.52

Cdh

1.00

1.00

Pdh Tj = +7°C

6.10 kW

6.50 kW

COP Tj = +7°C

5.75

4.54

Cdh

1.00

1.00

Pdh Tj = 12°C

5.50 kW

5.20 kW

COP Tj = 12°C

6.97

5.97

Cdh

1.00

1.00

Pdh Tj = Tbiv

10.72 kW

12.50 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

12.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.84

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electrical

electrical

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5765 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

101 %

COP

2.38

Heating up time

1:25 h:min

Standby power input

49.0 W

Reference hot water temperature

47.0 °C

Mixed water at 40°C

149 l

EPRA16DW / ETSHB16P30D
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

7.24 kW

El input

1.80 kW

2.47 kW

COP

5.00

2.93

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

140 %

Prated

13.00 kW

13.00 kW

SCOP

4.48

3.57

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.72 kW

11.10 kW

COP Tj = -7°C

2.97

2.43

Cdh

1.00

1.00

Pdh Tj = +2°C

6.87 kW

6.70 kW

COP Tj = +2°C

4.94

3.52

Cdh

1.00

1.00

Pdh Tj = +7°C

6.10 kW

6.50 kW

COP Tj = +7°C

5.75

4.54

Cdh

1.00

1.00

Pdh Tj = 12°C

5.50 kW

5.20 kW

COP Tj = 12°C

6.97

5.97

Cdh

1.00

1.00

Pdh Tj = Tbiv

10.72 kW

12.50 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

12.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.84

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electrical

electrical

Supplementary Heater: PSUP

9.00 kW

9.00 kW

Annual energy consumption Qhe

5765 kWh

7236 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

101 %

COP

2.38

Heating up time

1:25 h:min

Standby power input

49.0 W

Reference hot water temperature

47.0 °C

Mixed water at 40°C

149 l

EPRA16DV / ETSX16P30D
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

7.24 kW

El input

1.80 kW

2.41 kW

COP

5.00

3.01

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

142 %

Prated

13.00 kW

13.00 kW

SCOP

4.57

3.62

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.10 kW

11.20 kW

COP Tj = -7°C

3.12

2.47

Cdh

1.00

1.00

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.44

3.56

Cdh

1.00

1.00

Pdh Tj = +7°C

5.70 kW

6.90 kW

COP Tj = +7°C

5.84

4.44

Cdh

1.00

1.00

Pdh Tj = 12°C

6.00 kW

6.20 kW

COP Tj = 12°C

7.40

5.72

Cdh

1.00

1.00

Pdh Tj = Tbiv

11.10 kW

12.20 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.10 kW

12.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electrical

electrical

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5649 kWh

7134 kWh

Cooling

EN 14511-2

+7°C/+12°C

El input

2.54 kW

Cooling capacity

7.88

EER

2.69

EN 14825

+7°C/+12°C

Pdesignc

7.88 kW

SEER

4.08

Pdc Tj = 35°C

7.88 kW

EER Tj = 35°C

2.69

Pdc Tj = 30°C

5.92 kW

EER Tj = 30°C

3.69

Cdc

1.0

Pdc Tj = 25°C

5.09 kW

EER Tj = 25°C

4.63

Cdc

1.0

Pdc Tj = 20°C

5.13 kW

EER Tj = 20°C

5.61

Cdc

1.0

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1158 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

101 %

COP

2.38

Heating up time

1:41 h:min

Standby power input

49.0 W

Reference hot water temperature

47.0 °C

Mixed water at 40°C

149 l

EPRA16DV / ETSXB16P30D
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

7.24 kW

El input

1.80 kW

2.41 kW

COP

5.00

3.01

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

142 %

Prated

13.00 kW

13.00 kW

SCOP

4.57

3.62

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.10 kW

11.20 kW

COP Tj = -7°C

3.12

2.47

Cdh

1.00

1.00

Pdh Tj = +2°C

6.70 kW

6.90 kW

COP Tj = +2°C

4.44

3.56

Cdh

1.00

1.00

Pdh Tj = +7°C

5.70 kW

6.90 kW

COP Tj = +7°C

5.84

4.44

Cdh

1.00

1.00

Pdh Tj = 12°C

6.00 kW

6.20 kW

COP Tj = 12°C

7.40

5.72

Cdh

1.00

1.00

Pdh Tj = Tbiv

11.10 kW

12.20 kW

COP Tj = Tbiv

3.12

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.10 kW

12.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

2.19

WTOL

35 °C

55 °C

Poff

21 W

21 W

PTO

41 W

41 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electrical

electrical

Supplementary Heater: PSUP

9.00 kW

9.00 kW

Annual energy consumption Qhe

5649 kWh

7134 kWh

Cooling

EN 14511-2

+7°C/+12°C

El input

2.54 kW

Cooling capacity

7.88

EER

2.69

EN 14825

+7°C/+12°C

Pdesignc

7.88 kW

SEER

4.08

Pdc Tj = 35°C

7.88 kW

EER Tj = 35°C

2.69

Pdc Tj = 30°C

5.92 kW

EER Tj = 30°C

3.69

Cdc

1.0

Pdc Tj = 25°C

5.09 kW

EER Tj = 25°C

4.63

Cdc

1.0

Pdc Tj = 20°C

5.13 kW

EER Tj = 20°C

5.61

Cdc

1.0

Poff

21 W

PTO

41 W

PSB

21 W

PCK

0 W

Annual energy consumption Qce

1158 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

101 %

COP

2.38

Heating up time

1:41 h:min

Standby power input

49.0 W

Reference hot water temperature

47.0 °C

Mixed water at 40°C

149 l

EPRA16DW / ETSX16P30D
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

7.24 kW

El input

1.80 kW

2.47 kW

COP

5.00

2.93

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

142 %

Prated

13.00 kW

13.00 kW

SCOP

4.57

3.63

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.72 kW

11.10 kW

COP Tj = -7°C

2.97

2.43

Cdh

1.00

1.00

Pdh Tj = +2°C

6.87 kW

6.70 kW

COP Tj = +2°C

4.94

3.52

Cdh

1.00

1.00

Pdh Tj = +7°C

6.10 kW

6.50 kW

COP Tj = +7°C

5.75

4.54

Cdh

1.00

1.00

Pdh Tj = 12°C

5.50 kW

5.20 kW

COP Tj = 12°C

6.97

5.97

Cdh

1.00

1.00

Pdh Tj = Tbiv

10.72 kW

12.50 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

12.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.84

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electrical

electrical

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5651 kWh

7122 kWh

Cooling

EN 14511-2

+7°C/+12°C

El input

3.32 kW

Cooling capacity

7.88

EER

2.69

EN 14825

+7°C/+12°C

Pdesignc

7.88 kW

SEER

4.07

Pdc Tj = 35°C

7.88 kW

EER Tj = 35°C

2.69

Pdc Tj = 30°C

5.92 kW

EER Tj = 30°C

3.69

Cdc

1.0

Pdc Tj = 25°C

5.09 kW

EER Tj = 25°C

4.63

Cdc

1.0

Pdc Tj = 20°C

5.13 kW

EER Tj = 20°C

5.61

Cdc

1.0

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1188 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

101 %

COP

2.38

Heating up time

1:25 h:min

Standby power input

49.0 W

Reference hot water temperature

47.0 °C

Mixed water at 40°C

149 l

EPRA16DW / ETSXB16P30D
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

7.24 kW

El input

1.80 kW

2.47 kW

COP

5.00

2.93

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

142 %

Prated

13.00 kW

13.00 kW

SCOP

4.57

3.63

Tbiv

-7 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.72 kW

11.10 kW

COP Tj = -7°C

2.97

2.43

Cdh

1.00

1.00

Pdh Tj = +2°C

6.87 kW

6.70 kW

COP Tj = +2°C

4.94

3.52

Cdh

1.00

1.00

Pdh Tj = +7°C

6.10 kW

6.50 kW

COP Tj = +7°C

5.75

4.54

Cdh

1.00

1.00

Pdh Tj = 12°C

5.50 kW

5.20 kW

COP Tj = 12°C

6.97

5.97

Cdh

1.00

1.00

Pdh Tj = Tbiv

10.72 kW

12.50 kW

COP Tj = Tbiv

2.97

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.80 kW

12.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.84

2.12

WTOL

35 °C

55 °C

Poff

31 W

31 W

PTO

33 W

33 W

PSB

42 W

42 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electrical

electrical

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5651 kWh

7122 kWh

Cooling

EN 14511-2

+7°C/+12°C

El input

3.32 kW

Cooling capacity

7.88

EER

2.69

EN 14825

+7°C/+12°C

Pdesignc

7.88 kW

SEER

4.07

Pdc Tj = 35°C

7.88 kW

EER Tj = 35°C

2.69

Pdc Tj = 30°C

5.92 kW

EER Tj = 30°C

3.69

Cdc

1.0

Pdc Tj = 25°C

5.09 kW

EER Tj = 25°C

4.63

Cdc

1.0

Pdc Tj = 20°C

5.13 kW

EER Tj = 20°C

5.61

Cdc

1.0

Poff

31 W

PTO

33 W

PSB

42 W

PCK

0 W

Annual energy consumption Qce

1188 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

101 %

COP

2.38

Heating up time

1:25 h:min

Standby power input

49.0 W

Reference hot water temperature

47.0 °C

Mixed water at 40°C

149 l