Certificate holders

Subtype

WELLEA MONOBLOC 5/7/9 KW 1ph

Certificate Holder
Airwell Residential S.A.S.
10, rue du Fort de Saint Cyr
78180 Montigny le Bretonneux
France
Registration number
ICIM-PDC-000056-00
Certification Body
ICIM S.p.A.
Subtype title
WELLEA MONOBLOC 5/7/9 KW 1ph
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,000 kg

Certification Date
17.01.2020
Testing basis
EN 14511:2013, EN 14825:2016, EN 12102:2013
Generate PDF Export model CSV Download certificate
  • Number of models 3

Models

WELLEA MONOBLOC 5KW
Configure model
Model name
WELLEA MONOBLOC 5KW
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.65 kW

4.65 kW

El input

0.93 kW

1.77 kW

COP

5.00

2.63

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

127 %

Prated

7.00 kW

7.00 kW

SCOP

4.47

3.24

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.88 kW

5.83 kW

COP Tj = -7°C

2.91

1.97

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

3.64 kW

3.68 kW

COP Tj = +2°C

4.38

3.22

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

2.42 kW

2.47 kW

COP Tj = +7°C

5.89

4.21

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

1.03 kW

1.26 kW

COP Tj = 12°C

5.89

4.91

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

5.88 kW

5.83 kW

COP Tj = Tbiv

2.91

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.62 kW

5.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.62

WTOL

60 °C

60 °C

Poff

9 W

9 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.70 kW

Annual energy consumption Qhe

3071 kWh

4203 kWh

WELLEA MONOBLOC 7KW
Configure model
Model name
WELLEA MONOBLOC 7KW
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.65 kW

6.80 kW

El input

1.35 kW

2.42 kW

COP

4.94

2.81

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

127 %

Prated

7.00 kW

7.00 kW

SCOP

4.47

3.24

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.88 kW

5.83 kW

COP Tj = -7°C

2.91

1.97

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

3.64 kW

3.68 kW

COP Tj = +2°C

4.38

3.22

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

2.42 kW

2.47 kW

COP Tj = +7°C

5.89

4.21

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

1.03 kW

1.26 kW

COP Tj = 12°C

5.89

4.91

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

5.88 kW

5.83 kW

COP Tj = Tbiv

2.91

1.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.62 kW

5.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.62

WTOL

60 °C

60 °C

Poff

9 W

9 W

PTO

6 W

6 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.70 kW

Annual energy consumption Qhe

3701 kWh

4203 kWh

WELLEA MONOBLOC 9KW
Configure model
Model name
WELLEA MONOBLOC 9KW
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.60 kW

8.60 kW

El input

1.87 kW

3.12 kW

COP

4.60

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

126 %

Prated

8.00 kW

7.00 kW

SCOP

4.51

3.22

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.42 kW

6.58 kW

COP Tj = -7°C

2.80

1.87

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

4.83 kW

4.25 kW

COP Tj = +2°C

4.33

3.19

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.20 kW

2.80 kW

COP Tj = +7°C

6.20

4.38

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

1.55 kW

1.27 kW

COP Tj = 12°C

7.61

5.04

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

7.42 kW

6.58 kW

COP Tj = Tbiv

2.80

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.64 kW

5.53 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.51

WTOL

60 °C

60 °C

Poff

9 W

9 W

PTO

10 W

10 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.80 kW

1.80 kW

Annual energy consumption Qhe

3844 kWh

4770 kWh