4,400 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.95 kW
7.37 kW
El input
1.64 kW
2.45 kW
COP
4.86
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
133 %
Prated
13.31 kW
12.62 kW
SCOP
4.76
3.47
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.77 kW
11.16 kW
COP Tj = -7°C
3.24
2.29
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
7.31 kW
6.97 kW
COP Tj = +2°C
4.52
3.27
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
4.69 kW
4.42 kW
COP Tj = +7°C
6.39
4.46
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
4.72 kW
4.77 kW
COP Tj = 12°C
7.55
6.28
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
11.77 kW
11.16 kW
COP Tj = Tbiv
3.24
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.25 kW
12.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.84
2.13
WTOL
65 °C
65 °C
Poff
28 W
28 W
PTO
28 W
28 W
PSB
28 W
28 W
PCK
28 W
28 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.06 kW
0.03 kW
Annual energy consumption Qhe
5889 kWh
7658 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.95 kW
7.37 kW
El input
1.64 kW
2.45 kW
COP
4.86
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
51 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
133 %
Prated
13.31 kW
12.62 kW
SCOP
4.76
3.47
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.77 kW
11.16 kW
COP Tj = -7°C
3.24
2.29
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
7.31 kW
6.97 kW
COP Tj = +2°C
4.52
3.27
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
4.69 kW
4.42 kW
COP Tj = +7°C
6.39
4.46
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
4.72 kW
4.77 kW
COP Tj = 12°C
7.55
6.28
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
11.77 kW
11.16 kW
COP Tj = Tbiv
3.24
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.25 kW
12.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.84
2.13
WTOL
65 °C
65 °C
Poff
28 W
28 W
PTO
28 W
28 W
PSB
28 W
28 W
PCK
28 W
28 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.06 kW
0.03 kW
Annual energy consumption Qhe
5889 kWh
7658 kWh