Certificate holders

Subtype

DAIKIN ALTHERMA 3 R F 8KW (230L)

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Reg. No.
011-1W0222
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA 3 R F 8KW (230L)
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass Of Refrigerant

1,500 kg

Certification Date
22.11.2017
Testing basis
HP KEYMARK certification scheme rules rev. 7
Generate PDF Export model CSV
  • Number of models 15

Models

ERGA08DV / EHVX08S23D9W(G)
General Data
Power supply
1x230V 50Hz

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

131 %

Prated

8.00 kW

8.00 kW

SCOP

4.61

3.35

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.00 kW

6.90 kW

COP Tj = -7°C

2.77

1.96

Cdh

n/a

1.00

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.35

3.20

Cdh

1.00

1.00

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

6.49

4.64

Cdh

1.00

1.00

Pdh Tj = 12°C

3.90 kW

4.10 kW

COP Tj = 12°C

8.52

6.22

Cdh

1.00

1.00

Pdh Tj = Tbiv

7.50 kW

7.50 kW

COP Tj = Tbiv

2.66

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh

1.00

1.00

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

1.10 kW

0.90 kW

Annual energy consumption Qhe

3588 kWh

4939 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

1.63 kW

2.78 kW

COP

4.60

2.70

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Cooling

EN 14511-2

+7°C/+12°C

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.40 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc

1.0

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc

1.0

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc

1.0

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.30

Heating up time

1:47 h:min

Standby power input

28.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

288 l

ERGA08DV / EHVZ08S23D6V(G)
General Data
Power supply
1x230V 50Hz

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

130 %

Prated

8.00 kW

8.00 kW

SCOP

4.56

3.32

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.00 kW

6.90 kW

COP Tj = -7°C

2.77

1.96

Cdh

n/a

1.00

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.35

3.20

Cdh

1.00

1.00

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

6.49

4.64

Cdh

1.00

1.00

Pdh Tj = 12°C

3.90 kW

4.10 kW

COP Tj = 12°C

8.52

6.22

Cdh

1.00

1.00

Pdh Tj = Tbiv

7.50 kW

7.50 kW

COP Tj = Tbiv

2.66

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh

1.00

1.00

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

1.10 kW

0.90 kW

Annual energy consumption Qhe

3625 kWh

4975 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

1.63 kW

2.78 kW

COP

4.60

2.70

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.30

Heating up time

1:47 h:min

Standby power input

28.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

288 l

ERGA08DV / EHVZ08S23D9W(G)
General Data
Power supply
1x230V 50Hz

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

130 %

Prated

8.00 kW

8.00 kW

SCOP

4.56

3.32

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.00 kW

6.90 kW

COP Tj = -7°C

2.77

1.96

Cdh

n/a

1.00

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.35

3.20

Cdh

1.00

1.00

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

6.49

4.64

Cdh

1.00

1.00

Pdh Tj = 12°C

3.90 kW

4.10 kW

COP Tj = 12°C

8.52

6.22

Cdh

1.00

1.00

Pdh Tj = Tbiv

7.50 kW

7.50 kW

COP Tj = Tbiv

2.66

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh

1.00

1.00

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

1.10 kW

0.90 kW

Annual energy consumption Qhe

3625 kWh

4975 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

1.63 kW

2.78 kW

COP

4.60

2.70

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.30

Heating up time

1:47 h:min

Standby power input

28.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

288 l

ERGA08DV / EHVH08S23D6V(G)
General Data
Power supply
1x230V 50Hz

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

130 %

Prated

8.00 kW

8.00 kW

SCOP

4.56

3.32

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.00 kW

6.90 kW

COP Tj = -7°C

2.77

1.96

Cdh

n/a

1.00

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.35

3.20

Cdh

1.00

1.00

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

6.49

4.64

Cdh

1.00

1.00

Pdh Tj = 12°C

3.90 kW

4.10 kW

COP Tj = 12°C

8.52

6.22

Cdh

1.00

1.00

Pdh Tj = Tbiv

7.50 kW

7.50 kW

COP Tj = Tbiv

2.66

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh

1.00

1.00

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

1.10 kW

0.90 kW

Annual energy consumption Qhe

3625 kWh

4975 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

1.63 kW

2.78 kW

COP

4.60

2.70

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.30

Heating up time

1:47 h:min

Standby power input

28.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

288 l

ERGA08DV / EHVH08S23D9W(G)
General Data
Power supply
1x230V 50Hz

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

130 %

Prated

8.00 kW

8.00 kW

SCOP

4.56

3.32

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.00 kW

6.90 kW

COP Tj = -7°C

2.77

1.96

Cdh

n/a

1.00

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.35

3.20

Cdh

1.00

1.00

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

6.49

4.64

Cdh

1.00

1.00

Pdh Tj = 12°C

3.90 kW

4.10 kW

COP Tj = 12°C

8.52

6.22

Cdh

1.00

1.00

Pdh Tj = Tbiv

7.50 kW

7.50 kW

COP Tj = Tbiv

2.66

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh

1.00

1.00

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

1.10 kW

0.90 kW

Annual energy consumption Qhe

3625 kWh

4975 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

1.63 kW

2.78 kW

COP

4.60

2.70

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.30

Heating up time

1:47 h:min

Standby power input

28.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

288 l

ERGA08EV / EHVX08S23E9W
General Data
Power supply
1x230V 50Hz

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

131 %

Prated

8.00 kW

8.00 kW

SCOP

4.61

3.35

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.00 kW

6.90 kW

COP Tj = -7°C

2.77

1.96

Cdh

n/a

1.00

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.35

3.20

Cdh

1.00

1.00

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

6.49

4.64

Cdh

1.00

1.00

Pdh Tj = 12°C

3.90 kW

4.10 kW

COP Tj = 12°C

8.52

6.22

Cdh

1.00

1.00

Pdh Tj = Tbiv

7.50 kW

7.50 kW

COP Tj = Tbiv

2.66

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh

1.00

1.00

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

1.10 kW

0.90 kW

Annual energy consumption Qhe

3588 kWh

4939 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

1.63 kW

2.78 kW

COP

4.60

2.70

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.73 kW

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.40 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc

1.0

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc

1.0

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc

1.0

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.30

Heating up time

1:47 h:min

Standby power input

28.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

288 l

ERGA08EV / EHVH08S23E6V
General Data
Power supply
1x230V 50Hz

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

130 %

Prated

8.00 kW

8.00 kW

SCOP

4.56

3.32

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.00 kW

6.90 kW

COP Tj = -7°C

2.77

1.96

Cdh

n/a

1.00

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.35

3.20

Cdh

1.00

1.00

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

6.49

4.64

Cdh

1.00

1.00

Pdh Tj = 12°C

3.90 kW

4.10 kW

COP Tj = 12°C

8.52

6.22

Cdh

1.00

1.00

Pdh Tj = Tbiv

7.50 kW

7.50 kW

COP Tj = Tbiv

2.66

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh

1.00

1.00

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

1.10 kW

0.90 kW

Annual energy consumption Qhe

3625 kWh

4975 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

1.63 kW

2.78 kW

COP

4.60

2.70

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.30

Heating up time

1:47 h:min

Standby power input

28.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

288 l

ERGA08EV / EHVH08S23E9W
General Data
Power supply
1x230V 50Hz

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

130 %

Prated

8.00 kW

8.00 kW

SCOP

4.56

3.32

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.00 kW

6.90 kW

COP Tj = -7°C

2.77

1.96

Cdh

n/a

1.00

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.35

3.20

Cdh

1.00

1.00

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

6.49

4.64

Cdh

1.00

1.00

Pdh Tj = 12°C

3.90 kW

4.10 kW

COP Tj = 12°C

8.52

6.22

Cdh

1.00

1.00

Pdh Tj = Tbiv

7.50 kW

7.50 kW

COP Tj = Tbiv

2.66

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh

1.00

1.00

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

1.10 kW

0.90 kW

Annual energy consumption Qhe

3625 kWh

4975 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

1.63 kW

2.78 kW

COP

4.60

2.70

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.30

Heating up time

1:47 h:min

Standby power input

28.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

288 l

ERGA08EV / EHVH08S23E6V + cooling kit
General Data
Power supply
1x230V 50Hz

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

130 %

Prated

8.00 kW

8.00 kW

SCOP

4.56

3.32

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.00 kW

6.90 kW

COP Tj = -7°C

2.77

1.96

Cdh

n/a

1.00

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.35

3.20

Cdh

1.00

1.00

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

6.49

4.64

Cdh

1.00

1.00

Pdh Tj = 12°C

3.90 kW

4.10 kW

COP Tj = 12°C

8.52

6.22

Cdh

1.00

1.00

Pdh Tj = Tbiv

7.50 kW

7.50 kW

COP Tj = Tbiv

2.66

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh

1.00

1.00

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

1.10 kW

0.90 kW

Annual energy consumption Qhe

3625 kWh

4975 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

1.63 kW

2.78 kW

COP

4.60

2.70

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.73 kW

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.40 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc

1.0

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc

1.0

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc

1.0

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.30

Heating up time

1:47 h:min

Standby power input

28.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

288 l

ERGA08EV / EHVH08S23E9W + cooling kit
General Data
Power supply
1x230V 50Hz

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

130 %

Prated

8.00 kW

8.00 kW

SCOP

4.56

3.32

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.00 kW

6.90 kW

COP Tj = -7°C

2.77

1.96

Cdh

n/a

1.00

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.35

3.20

Cdh

1.00

1.00

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

6.49

4.64

Cdh

1.00

1.00

Pdh Tj = 12°C

3.90 kW

4.10 kW

COP Tj = 12°C

8.52

6.22

Cdh

1.00

1.00

Pdh Tj = Tbiv

7.50 kW

7.50 kW

COP Tj = Tbiv

2.66

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh

1.00

1.00

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

1.10 kW

0.90 kW

Annual energy consumption Qhe

3625 kWh

4975 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

1.63 kW

2.78 kW

COP

4.60

2.70

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.73 kW

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.40 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc

1.0

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc

1.0

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc

1.0

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.30

Heating up time

1:47 h:min

Standby power input

28.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

288 l

ERGA08EV / EHVH08SU23E6V
General Data
Power supply
1x230V 50Hz

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

130 %

Prated

8.00 kW

8.00 kW

SCOP

4.56

3.32

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.00 kW

6.90 kW

COP Tj = -7°C

2.77

1.96

Cdh

n/a

1.00

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.35

3.20

Cdh

1.00

1.00

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

6.49

4.64

Cdh

1.00

1.00

Pdh Tj = 12°C

3.90 kW

4.10 kW

COP Tj = 12°C

8.52

6.22

Cdh

1.00

1.00

Pdh Tj = Tbiv

7.50 kW

7.50 kW

COP Tj = Tbiv

2.66

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh

1.00

1.00

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

1.10 kW

0.90 kW

Annual energy consumption Qhe

3625 kWh

4975 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

1.63 kW

2.78 kW

COP

4.60

2.70

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.30

Heating up time

1:47 h:min

Standby power input

28.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

288 l

ERGA08EV / EHVZ08S23E6V + cooling kit
General Data
Power supply
1x230V 50Hz

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

130 %

Prated

8.00 kW

8.00 kW

SCOP

4.56

3.32

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.00 kW

6.90 kW

COP Tj = -7°C

2.77

1.96

Cdh

n/a

1.00

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.35

3.20

Cdh

1.00

1.00

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

6.49

4.64

Cdh

1.00

1.00

Pdh Tj = 12°C

3.90 kW

4.10 kW

COP Tj = 12°C

8.52

6.22

Cdh

1.00

1.00

Pdh Tj = Tbiv

7.50 kW

7.50 kW

COP Tj = Tbiv

2.66

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh

1.00

1.00

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

1.10 kW

0.90 kW

Annual energy consumption Qhe

3625 kWh

4975 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

1.63 kW

2.78 kW

COP

4.60

2.70

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.73 kW

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.40 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc

1.0

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc

1.0

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc

1.0

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.30

Heating up time

1:47 h:min

Standby power input

28.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

288 l

ERGA08EV / EHVZ08S23E9W + cooling kit
General Data
Power supply
1x230V 50Hz

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

130 %

Prated

8.00 kW

8.00 kW

SCOP

4.56

3.32

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.00 kW

6.90 kW

COP Tj = -7°C

2.77

1.96

Cdh

n/a

1.00

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.35

3.20

Cdh

1.00

1.00

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

6.49

4.64

Cdh

1.00

1.00

Pdh Tj = 12°C

3.90 kW

4.10 kW

COP Tj = 12°C

8.52

6.22

Cdh

1.00

1.00

Pdh Tj = Tbiv

7.50 kW

7.50 kW

COP Tj = Tbiv

2.66

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh

1.00

1.00

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

1.10 kW

0.90 kW

Annual energy consumption Qhe

3625 kWh

4975 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

1.63 kW

2.78 kW

COP

4.60

2.70

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.73 kW

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.40 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc

1.0

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc

1.0

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc

1.0

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.30

Heating up time

1:47 h:min

Standby power input

28.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

288 l

ERGA08DV / EHVX08S23D6V(G)
General Data
Power supply
1x230V 50Hz

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

131 %

Prated

8.00 kW

8.00 kW

SCOP

4.61

3.35

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.00 kW

6.90 kW

COP Tj = -7°C

2.77

1.96

Cdh

n/a

1.00

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.35

3.20

Cdh

1.00

1.00

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

6.49

4.64

Cdh

1.00

1.00

Pdh Tj = 12°C

3.90 kW

4.10 kW

COP Tj = 12°C

8.52

6.22

Cdh

1.00

1.00

Pdh Tj = Tbiv

7.50 kW

7.50 kW

COP Tj = Tbiv

2.66

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh

1.00

1.00

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

1.10 kW

0.90 kW

Annual energy consumption Qhe

3588 kWh

4939 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

1.63 kW

2.78 kW

COP

4.60

2.70

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Cooling

EN 14511-2

+7°C/+12°C

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.40 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc

1.0

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc

1.0

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc

1.0

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.30

Heating up time

1:47 h:min

Standby power input

28.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

288 l

ERGA08EV / EHVX08S23E6V(G)
General Data
Power supply
1x230V 50Hz

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

131 %

Prated

8.00 kW

8.00 kW

SCOP

4.61

3.35

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.00 kW

6.90 kW

COP Tj = -7°C

2.77

1.96

Cdh

n/a

1.00

Pdh Tj = +2°C

4.20 kW

4.40 kW

COP Tj = +2°C

4.35

3.20

Cdh

1.00

1.00

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

6.49

4.64

Cdh

1.00

1.00

Pdh Tj = 12°C

3.90 kW

4.10 kW

COP Tj = 12°C

8.52

6.22

Cdh

1.00

1.00

Pdh Tj = Tbiv

7.50 kW

7.50 kW

COP Tj = Tbiv

2.66

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.90 kW

7.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.41

1.64

Cdh

1.00

1.00

WTOL

35 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

1.10 kW

0.90 kW

Annual energy consumption Qhe

3588 kWh

4939 kWh

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.50 kW

7.50 kW

El input

1.63 kW

2.78 kW

COP

4.60

2.70

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

1.73 kW

Cooling capacity

5.44

EER

3.14

EN 14825

+7°C/+12°C

Pdesignc

5.40 kW

SEER

5.71

Pdc Tj = 35°C

5.44 kW

EER Tj = 35°C

3.14

Pdc Tj = 30°C

4.02 kW

EER Tj = 30°C

4.84

Cdc

1.0

Pdc Tj = 25°C

2.47 kW

EER Tj = 25°C

6.86

Cdc

1.0

Pdc Tj = 20°C

2.54 kW

EER Tj = 20°C

8.47

Cdc

1.0

Poff

10 W

PTO

10 W

PSB

10 W

PCK

0 W

Annual energy consumption Qce

571 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

133 %

COP

3.30

Heating up time

1:47 h:min

Standby power input

28.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

288 l