1,950 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.82 kW
15.68 kW
El input
1.57 kW
5.19 kW
COP
4.98
3.02
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
238 %
174 %
Prated
15.05 kW
15.68 kW
SCOP
6.15
4.55
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
9.11 kW
9.49 kW
COP Tj = -7°C
5.93
4.22
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
5.54 kW
5.78 kW
COP Tj = +2°C
6.61
4.97
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
4.42 kW
4.35 kW
COP Tj = +7°C
6.58
5.32
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
4.39 kW
4.36 kW
COP Tj = 12°C
6.30
5.36
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
15.05 kW
15.68 kW
COP Tj = Tbiv
4.69
3.02
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.05 kW
15.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.69
3.02
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
6027 kWh
8487 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
168 %
Prated
15.05 kW
15.68 kW
SCOP
5.90
4.40
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.31 kW
13.87 kW
COP Tj = -7°C
5.04
3.38
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
8.10 kW
8.44 kW
COP Tj = +2°C
5.91
4.42
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.21 kW
5.43 kW
COP Tj = +7°C
6.65
5.10
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
4.41 kW
4.34 kW
COP Tj = 12°C
6.49
5.25
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
15.05 kW
15.68 kW
COP Tj = Tbiv
4.69
3.02
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.05 kW
15.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.69
3.02
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5270 kWh
7367 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
12.52 kW
17.55 kW
El input
1.87 kW
4.59 kW
COP
6.68
3.82
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
332 %
232 %
Prated
12.52 kW
17.55 kW
SCOP
8.49
6.01
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.58 kW
10.62 kW
COP Tj = -7°C
8.34
5.49
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
5.86 kW
6.47 kW
COP Tj = +2°C
9.06
6.68
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
5.88 kW
5.72 kW
COP Tj = +7°C
9.26
7.08
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
5.87 kW
5.75 kW
COP Tj = 12°C
9.12
7.29
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
12.52 kW
17.55 kW
COP Tj = Tbiv
6.68
3.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.52 kW
17.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.68
3.82
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3633 kWh
7199 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
319 %
223 %
Prated
12.52 kW
17.55 kW
SCOP
8.18
5.78
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.07 kW
15.53 kW
COP Tj = -7°C
7.10
4.23
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
6.74 kW
9.45 kW
COP Tj = +2°C
8.44
5.84
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
5.85 kW
6.08 kW
COP Tj = +7°C
8.98
6.90
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
5.89 kW
5.72 kW
COP Tj = 12°C
9.30
7.07
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
12.52 kW
17.55 kW
COP Tj = Tbiv
6.68
3.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.52 kW
17.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.68
3.82
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3160 kWh
6273 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.82 kW
15.68 kW
El input
1.57 kW
5.19 kW
COP
4.98
3.02
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
238 %
174 %
Prated
15.05 kW
15.68 kW
SCOP
6.15
4.55
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
9.11 kW
9.49 kW
COP Tj = -7°C
5.93
4.22
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
5.54 kW
5.78 kW
COP Tj = +2°C
6.61
4.97
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
4.42 kW
4.35 kW
COP Tj = +7°C
6.58
5.32
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
4.39 kW
4.36 kW
COP Tj = 12°C
6.30
5.36
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
15.05 kW
15.68 kW
COP Tj = Tbiv
4.69
3.02
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.05 kW
15.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.69
3.02
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
6027 kWh
8487 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
168 %
Prated
15.05 kW
15.68 kW
SCOP
5.90
4.40
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.31 kW
13.87 kW
COP Tj = -7°C
5.04
3.38
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
8.10 kW
8.44 kW
COP Tj = +2°C
5.91
4.42
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.21 kW
5.43 kW
COP Tj = +7°C
6.65
5.10
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
4.41 kW
4.34 kW
COP Tj = 12°C
6.49
5.25
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
15.05 kW
15.68 kW
COP Tj = Tbiv
4.69
3.02
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.05 kW
15.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.69
3.02
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5270 kWh
7367 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
12.52 kW
17.55 kW
El input
1.87 kW
4.59 kW
COP
6.68
3.82
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
332 %
232 %
Prated
12.52 kW
17.55 kW
SCOP
8.49
6.01
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.58 kW
10.62 kW
COP Tj = -7°C
8.34
5.49
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
5.86 kW
6.47 kW
COP Tj = +2°C
9.06
6.68
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
5.88 kW
5.72 kW
COP Tj = +7°C
9.26
7.08
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
5.87 kW
5.75 kW
COP Tj = 12°C
9.12
7.29
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
12.52 kW
17.55 kW
COP Tj = Tbiv
6.68
3.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.52 kW
17.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.68
3.82
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3633 kWh
7199 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
319 %
223 %
Prated
12.52 kW
17.55 kW
SCOP
8.18
5.78
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.07 kW
15.53 kW
COP Tj = -7°C
7.10
4.23
Cdh Tj = -7 °C
0.99
1.00
Pdh Tj = +2°C
6.74 kW
9.45 kW
COP Tj = +2°C
8.44
5.84
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
5.85 kW
6.08 kW
COP Tj = +7°C
8.98
6.90
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
5.89 kW
5.72 kW
COP Tj = 12°C
9.30
7.07
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
12.52 kW
17.55 kW
COP Tj = Tbiv
6.68
3.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.52 kW
17.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.68
3.82
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3160 kWh
6273 kWh