Certificate holders

Subtype

F7x0

Certificate Holder
Nibe AB
Box 14
S-28521 Markaryd
Sweden
Registration number
012-025
Certification Body
RISE CERT
Subtype title
F7x0
Driving energy
n/a
Heat Pump Type
Exhaust Air/Water
Refrigerant
R407c
Mass of Refrigerant

0,740 kg

Certification Date
n/a
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

F730
Configure model
Model name
F730
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.19 kW

3.52 kW

El input

0.92 kW

1.51 kW

COP

3.47

2.33

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

174 %

133 %

Prated

4.50 kW

4.50 kW

SCOP

4.43

3.40

Tbiv

5 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.60 kW

3.60 kW

COP Tj = +2°C

3.10

2.30

Pdh Tj = +7°C

2.90 kW

2.90 kW

COP Tj = +7°C

3.90

3.00

Pdh Tj = 12°C

1.50 kW

1.70 kW

COP Tj = 12°C

5.90

4.30

Pdh Tj = Tbiv

3.60 kW

3.90 kW

COP Tj = Tbiv

3.30

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.60 kW

3.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

2.30

Rated airflow rate

180 m³/h

180 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.94

0.97

WTOL

60 °C

60 °C

Poff

3 W

3 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

1359 kWh

1766 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

140 %

Prated

4.50 kW

4.50 kW

SCOP

4.65

3.58

Tbiv

-12 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

2.80 kW

2.80 kW

COP Tj = -7°C

4.30

3.10

Pdh Tj = +2°C

1.70 kW

1.70 kW

COP Tj = +2°C

5.40

4.20

Pdh Tj = +7°C

1.50 kW

1.70 kW

COP Tj = +7°C

5.90

4.30

Pdh Tj = 12°C

1.50 kW

1.70 kW

COP Tj = 12°C

4.90

4.00

Pdh Tj = Tbiv

3.30 kW

3.80 kW

COP Tj = Tbiv

3.40

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.60 kW

3.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

2.30

Rated airflow rate

180 m³/h

180 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.92

0.96

WTOL

65 °C

65 °C

Poff

3 W

3 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

2389 kWh

3105 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

132 %

Prated

4.50 kW

4.50 kW

SCOP

4.38

3.38

Tbiv

-5 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.50 kW

4.00 kW

COP Tj = -7°C

3.20

2.30

Pdh Tj = +2°C

2.60 kW

2.80 kW

COP Tj = +2°C

4.50

3.30

Pdh Tj = +7°C

1.60 kW

1.70 kW

COP Tj = +7°C

5.80

4.30

Pdh Tj = 12°C

1.50 kW

1.70 kW

COP Tj = 12°C

5.50

4.20

Pdh Tj = Tbiv

3.60 kW

4.00 kW

COP Tj = Tbiv

3.20

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.60 kW

3.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

2.30

Rated airflow rate

180 m³/h

180 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.93

0.97

WTOL

65 °C

65 °C

Poff

3 W

3 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

2758 kWh

2756 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.28

Heating up time

04:30 h:min

Standby power input

50.0 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

210 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.28

Heating up time

04:30 h:min

Standby power input

50.0 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

210 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.28

Heating up time

04:30 h:min

Standby power input

50.0 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

210 l

F750
Configure model
Model name
F750
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
No

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.19 kW

3.52 kW

El input

0.92 kW

1.51 kW

COP

3.47

2.33

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

174 %

133 %

Prated

4.50 kW

4.50 kW

SCOP

4.43

3.40

Tbiv

5 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.60 kW

3.60 kW

COP Tj = +2°C

3.10

2.30

Pdh Tj = +7°C

2.90 kW

2.90 kW

COP Tj = +7°C

3.90

3.00

Pdh Tj = 12°C

1.50 kW

1.70 kW

COP Tj = 12°C

5.90

4.30

Pdh Tj = Tbiv

3.60 kW

3.90 kW

COP Tj = Tbiv

3.30

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.60 kW

3.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

2.30

Rated airflow rate

180 m³/h

180 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.94

0.97

WTOL

60 °C

60 °C

Poff

3 W

3 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

1359 kWh

1766 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

140 %

Prated

4.50 kW

4.50 kW

SCOP

4.65

3.58

Tbiv

-12 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

2.80 kW

2.80 kW

COP Tj = -7°C

4.30

3.10

Pdh Tj = +2°C

1.70 kW

1.70 kW

COP Tj = +2°C

5.40

4.20

Pdh Tj = +7°C

1.50 kW

1.70 kW

COP Tj = +7°C

5.90

4.30

Pdh Tj = 12°C

1.50 kW

1.70 kW

COP Tj = 12°C

4.90

4.00

Pdh Tj = Tbiv

3.30 kW

3.80 kW

COP Tj = Tbiv

3.40

2.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.60 kW

3.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

2.30

Rated airflow rate

180 m³/h

180 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.92

0.96

WTOL

65 °C

65 °C

Poff

3 W

3 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

2389 kWh

3105 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

132 %

Prated

4.50 kW

4.50 kW

SCOP

4.38

3.38

Tbiv

-5 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.50 kW

4.00 kW

COP Tj = -7°C

3.20

2.30

Pdh Tj = +2°C

2.60 kW

2.80 kW

COP Tj = +2°C

4.50

3.30

Pdh Tj = +7°C

1.60 kW

1.70 kW

COP Tj = +7°C

5.80

4.30

Pdh Tj = 12°C

1.50 kW

1.70 kW

COP Tj = 12°C

5.50

4.20

Pdh Tj = Tbiv

3.60 kW

4.00 kW

COP Tj = Tbiv

3.20

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.60 kW

3.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

2.30

Rated airflow rate

180 m³/h

180 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.93

0.97

WTOL

65 °C

65 °C

Poff

3 W

3 W

PTO

20 W

20 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

2758 kWh

2756 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.28

Heating up time

04:30 h:min

Standby power input

50.0 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

210 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.28

Heating up time

04:30 h:min

Standby power input

50.0 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

210 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

91 %

COP

2.28

Heating up time

04:30 h:min

Standby power input

50.0 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

210 l