Certificate holders

Subtype

Fx70

Certificate Holder
Nibe AB
Box 14
S-28521 Markaryd
Sweden
Registration number
012-036 / Issue 2
Certification Body
RISE CERT
Subtype title
Fx70
Driving energy
n/a
Heat Pump Type
Exhaust Air/Water
Refrigerant
R290
Mass of Refrigerant

0,400 kg

Certification Date
15.06.2017
Testing basis
HP Keymark Scheme 2017
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

F370 1x230
Configure model
Model name
F370 1x230
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

1.68 kW

1.68 kW

El input

0.46 kW

0.66 kW

COP

3.67

2.55

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

139 %

116 %

Prated

2.60 kW

2.60 kW

SCOP

3.55

2.97

Tbiv

-10 °C

-10 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.70 kW

1.70 kW

COP Tj = -7°C

4.04

3.16

Pdh Tj = +2°C

1.70 kW

1.70 kW

COP Tj = +2°C

3.99

3.34

Pdh Tj = +7°C

1.70 kW

1.70 kW

COP Tj = +7°C

3.88

3.41

Pdh Tj = 12°C

1.70 kW

1.70 kW

COP Tj = 12°C

3.35

3.11

Pdh Tj = Tbiv

1.70 kW

1.70 kW

COP Tj = Tbiv

4.00

3.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.70 kW

1.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.71

2.56

Rated airflow rate

180 m³/h

180 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.95

0.96

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

24 W

24 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

1808 kWh

2162 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

131 %

110 %

Prated

2.60 kW

2.60 kW

SCOP

3.35

2.82

Tbiv

-2 °C

-2 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

1.70 kW

1.70 kW

COP Tj = -7°C

3.78

2.72

Pdh Tj = +2°C

1.70 kW

1.70 kW

COP Tj = +2°C

3.98

3.22

Pdh Tj = +7°C

1.70 kW

1.70 kW

COP Tj = +7°C

1.96

3.37

Pdh Tj = 12°C

1.70 kW

1.70 kW

COP Tj = 12°C

3.65

3.28

Pdh Tj = Tbiv

1.70 kW

1.70 kW

COP Tj = Tbiv

3.91

3.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.70 kW

1.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.71

2.56

Rated airflow rate

180 m³/h

180 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.95

0.96

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

24 W

24 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

1598 kWh

1898 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

75 %

COP

1.90

Heating up time

07:16 h:min

Standby power input

85.0 W

Reference hot water temperature

50.2 °C

Mixed water at 40°C

217 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

75 %

COP

1.90

Heating up time

07:16 h:min

Standby power input

85.0 W

Reference hot water temperature

50.2 °C

Mixed water at 40°C

217 l

F370 3x400
Configure model
Model name
F370 3x400
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
No

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

1.68 kW

1.68 kW

El input

0.46 kW

0.66 kW

COP

3.67

2.55

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

139 %

116 %

Prated

2.60 kW

2.60 kW

SCOP

3.55

2.97

Tbiv

-10 °C

-10 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.70 kW

1.70 kW

COP Tj = -7°C

4.04

3.16

Pdh Tj = +2°C

1.70 kW

1.70 kW

COP Tj = +2°C

3.99

3.34

Pdh Tj = +7°C

1.70 kW

1.70 kW

COP Tj = +7°C

3.88

3.41

Pdh Tj = 12°C

1.70 kW

1.70 kW

COP Tj = 12°C

3.35

3.11

Pdh Tj = Tbiv

1.70 kW

1.70 kW

COP Tj = Tbiv

4.00

3.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.70 kW

1.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.71

2.56

Rated airflow rate

180 m³/h

180 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.95

0.96

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

24 W

24 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

1808 kWh

2162 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

131 %

110 %

Prated

2.60 kW

2.60 kW

SCOP

3.35

2.82

Tbiv

-2 °C

-2 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

1.70 kW

1.70 kW

COP Tj = -7°C

3.78

2.72

Pdh Tj = +2°C

1.70 kW

1.70 kW

COP Tj = +2°C

3.98

3.22

Pdh Tj = +7°C

1.70 kW

1.70 kW

COP Tj = +7°C

1.96

3.37

Pdh Tj = 12°C

1.70 kW

1.70 kW

COP Tj = 12°C

3.65

3.28

Pdh Tj = Tbiv

1.70 kW

1.70 kW

COP Tj = Tbiv

3.91

3.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.70 kW

1.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.71

2.56

Rated airflow rate

180 m³/h

180 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.95

0.96

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

24 W

24 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

1598 kWh

1898 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

75 %

COP

1.90

Heating up time

07:16 h:min

Standby power input

85.0 W

Reference hot water temperature

50.2 °C

Mixed water at 40°C

217 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

75 %

COP

1.90

Heating up time

07:16 h:min

Standby power input

85.0 W

Reference hot water temperature

50.2 °C

Mixed water at 40°C

217 l

F470 1x230
Configure model
Model name
F470 1x230
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

1.68 kW

1.68 kW

El input

0.46 kW

0.66 kW

COP

3.67

2.55

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

145 %

120 %

Prated

2.60 kW

2.60 kW

SCOP

3.70

3.07

Tbiv

-10 °C

-10 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.70 kW

1.70 kW

COP Tj = -7°C

4.04

3.16

Pdh Tj = +2°C

1.70 kW

1.70 kW

COP Tj = +2°C

3.99

3.34

Pdh Tj = +7°C

1.70 kW

1.70 kW

COP Tj = +7°C

3.88

3.41

Pdh Tj = 12°C

1.70 kW

1.70 kW

COP Tj = 12°C

3.35

3.11

Pdh Tj = Tbiv

1.70 kW

1.70 kW

COP Tj = Tbiv

4.00

3.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.70 kW

1.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.71

2.56

Rated airflow rate

180 m³/h

180 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.95

0.96

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

1737 kWh

2091 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

140 %

116 %

Prated

2.60 kW

2.60 kW

SCOP

3.57

2.97

Tbiv

-2 °C

-2 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

1.70 kW

1.70 kW

COP Tj = -7°C

3.78

2.72

Pdh Tj = +2°C

1.70 kW

1.70 kW

COP Tj = +2°C

3.98

3.22

Pdh Tj = +7°C

1.70 kW

1.70 kW

COP Tj = +7°C

1.96

3.37

Pdh Tj = 12°C

1.70 kW

1.70 kW

COP Tj = 12°C

3.65

3.28

Pdh Tj = Tbiv

1.70 kW

1.70 kW

COP Tj = Tbiv

3.91

3.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.70 kW

1.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.71

2.56

Rated airflow rate

180 m³/h

180 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.95

0.96

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

1505 kWh

1806 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

79 %

COP

2.00

Heating up time

07:16 h:min

Standby power input

65.0 W

Reference hot water temperature

50.2 °C

Mixed water at 40°C

217 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

79 %

COP

2.00

Heating up time

07:16 h:min

Standby power input

65.0 W

Reference hot water temperature

50.2 °C

Mixed water at 40°C

217 l

F470 3x400
Configure model
Model name
F470 3x400
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
No

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

1.68 kW

1.68 kW

El input

0.46 kW

0.66 kW

COP

3.67

2.55

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

145 %

120 %

Prated

2.60 kW

2.60 kW

SCOP

3.70

3.07

Tbiv

-10 °C

-10 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

1.70 kW

1.70 kW

COP Tj = -7°C

4.04

3.16

Pdh Tj = +2°C

1.70 kW

1.70 kW

COP Tj = +2°C

3.99

3.34

Pdh Tj = +7°C

1.70 kW

1.70 kW

COP Tj = +7°C

3.88

3.41

Pdh Tj = 12°C

1.70 kW

1.70 kW

COP Tj = 12°C

3.35

3.11

Pdh Tj = Tbiv

1.70 kW

1.70 kW

COP Tj = Tbiv

4.00

3.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.70 kW

1.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.71

2.56

Rated airflow rate

180 m³/h

180 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.95

0.96

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

1737 kWh

2091 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

140 %

116 %

Prated

2.60 kW

2.60 kW

SCOP

3.57

2.97

Tbiv

-2 °C

-2 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

1.70 kW

1.70 kW

COP Tj = -7°C

3.78

2.72

Pdh Tj = +2°C

1.70 kW

1.70 kW

COP Tj = +2°C

3.98

3.22

Pdh Tj = +7°C

1.70 kW

1.70 kW

COP Tj = +7°C

1.96

3.37

Pdh Tj = 12°C

1.70 kW

1.70 kW

COP Tj = 12°C

3.65

3.28

Pdh Tj = Tbiv

1.70 kW

1.70 kW

COP Tj = Tbiv

3.91

3.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.70 kW

1.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.71

2.56

Rated airflow rate

180 m³/h

180 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.95

0.96

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

20 W

20 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

1505 kWh

1806 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

79 %

COP

2.00

Heating up time

07:16 h:min

Standby power input

65.0 W

Reference hot water temperature

50.2 °C

Mixed water at 40°C

217 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

79 %

COP

2.00

Heating up time

07:16 h:min

Standby power input

65.0 W

Reference hot water temperature

50.2 °C

Mixed water at 40°C

217 l