4,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.40 kW
10.27 kW
El input
2.49 kW
3.71 kW
COP
4.18
2.64
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
149 %
121 %
Prated
9.90 kW
9.35 kW
SCOP
3.81
3.11
Tbiv
-5 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.53 kW
6.98 kW
COP Tj = -7°C
2.97
2.03
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
9.54 kW
9.41 kW
COP Tj = +2°C
3.78
3.11
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
10.43 kW
10.40 kW
COP Tj = +7°C
4.69
4.04
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
12.19 kW
12.17 kW
COP Tj = 12°C
5.15
5.02
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
8.00 kW
7.55 kW
COP Tj = Tbiv
3.19
2.25
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.84 kW
6.27 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
1.79
WTOL
65 °C
65 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.06 kW
3.08 kW
Annual energy consumption Qhe
5367 kWh
6216 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
179 %
145 %
Prated
11.53 kW
11.30 kW
SCOP
4.56
3.71
Tbiv
4 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.50 kW
9.23 kW
COP Tj = +2°C
3.56
2.52
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
10.42 kW
10.33 kW
COP Tj = +7°C
4.46
3.27
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
12.17 kW
12.10 kW
COP Tj = 12°C
5.08
4.61
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
9.88 kW
9.68 kW
COP Tj = Tbiv
3.94
2.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.50 kW
9.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.56
2.52
WTOL
65 °C
65 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.03 kW
2.07 kW
Annual energy consumption Qhe
3376 kWh
4069 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
132 %
108 %
Prated
8.82 kW
8.22 kW
SCOP
3.38
2.77
Tbiv
-12 °C
-12 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.62 kW
7.23 kW
COP Tj = -7°C
3.18
2.37
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
9.57 kW
9.48 kW
COP Tj = +2°C
3.92
3.40
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
10.44 kW
10.42 kW
COP Tj = +7°C
4.83
4.44
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
12.18 kW
12.20 kW
COP Tj = 12°C
5.00
5.18
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
6.50 kW
6.06 kW
COP Tj = Tbiv
2.77
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.66 kW
4.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.99
1.34
WTOL
65 °C
65 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
8.82 kW
8.22 kW
Annual energy consumption Qhe
6437 kWh
7306 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.80
5.37
COP Tj = -15°C (if TOL<-20°C)
2.47
1.72
Cdh Tj = -15 °C
1.00
1.00
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.40 kW
10.27 kW
El input
2.49 kW
3.71 kW
COP
4.18
2.64
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
149 %
121 %
Prated
9.90 kW
9.35 kW
SCOP
3.81
3.11
Tbiv
-5 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.53 kW
6.98 kW
COP Tj = -7°C
2.97
2.03
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
9.54 kW
9.41 kW
COP Tj = +2°C
3.78
3.11
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
10.43 kW
10.40 kW
COP Tj = +7°C
4.69
4.04
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
12.19 kW
12.17 kW
COP Tj = 12°C
5.15
5.02
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
8.00 kW
7.55 kW
COP Tj = Tbiv
3.19
2.25
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.84 kW
6.27 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
1.79
WTOL
65 °C
65 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.06 kW
3.08 kW
Annual energy consumption Qhe
5367 kWh
6216 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
179 %
145 %
Prated
11.53 kW
11.30 kW
SCOP
4.56
3.71
Tbiv
4 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.50 kW
9.23 kW
COP Tj = +2°C
3.56
2.52
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
10.42 kW
10.33 kW
COP Tj = +7°C
4.46
3.27
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
12.17 kW
12.10 kW
COP Tj = 12°C
5.08
4.61
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
9.88 kW
9.68 kW
COP Tj = Tbiv
3.94
2.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.50 kW
9.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.56
2.52
WTOL
65 °C
65 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.03 kW
2.07 kW
Annual energy consumption Qhe
3376 kWh
4069 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
132 %
108 %
Prated
8.82 kW
8.22 kW
SCOP
3.38
2.77
Tbiv
-12 °C
-12 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.62 kW
7.23 kW
COP Tj = -7°C
3.18
2.37
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
9.57 kW
9.48 kW
COP Tj = +2°C
3.92
3.40
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
10.44 kW
10.42 kW
COP Tj = +7°C
4.83
4.44
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
12.18 kW
12.20 kW
COP Tj = 12°C
5.00
5.18
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
6.50 kW
6.06 kW
COP Tj = Tbiv
2.77
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.66 kW
4.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.99
1.34
WTOL
65 °C
65 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
8.82 kW
8.22 kW
Annual energy consumption Qhe
6437 kWh
7306 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.80
5.37
COP Tj = -15°C (if TOL<-20°C)
2.47
1.72
Cdh Tj = -15 °C
1.00
1.00