4,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
13.70 kW
13.10 kW
El input
3.26 kW
5.95 kW
COP
4.20
2.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
144 %
115 %
Prated
13.51 kW
12.68 kW
SCOP
3.67
2.95
Tbiv
-4 °C
-4 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.54 kW
8.82 kW
COP Tj = -7°C
2.78
1.90
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
12.03 kW
11.62 kW
COP Tj = +2°C
3.66
2.92
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
13.95 kW
13.65 kW
COP Tj = +7°C
4.68
4.02
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
15.56 kW
15.50 kW
COP Tj = 12°C
4.93
4.79
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
10.39 kW
9.75 kW
COP Tj = Tbiv
3.11
2.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.68 kW
8.08 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.53
1.70
WTOL
58 °C
58 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.83 kW
4.60 kW
Annual energy consumption Qhe
7606 kWh
8876 kWh
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
175 %
140 %
Prated
14.81 kW
13.86 kW
SCOP
4.44
3.58
Tbiv
4 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.90 kW
11.10 kW
COP Tj = +2°C
3.40
2.30
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
13.83 kW
13.11 kW
COP Tj = +7°C
4.42
3.19
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
15.49 kW
15.26 kW
COP Tj = 12°C
4.84
4.41
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
12.69 kW
11.88 kW
COP Tj = Tbiv
3.84
2.61
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.90 kW
11.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.40
2.30
WTOL
58 °C
58 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.91 kW
2.76 kW
Annual energy consumption Qhe
4452 kWh
5174 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
128 %
104 %
Prated
8.99 kW
8.71 kW
SCOP
3.28
2.69
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
9.64 kW
9.14 kW
COP Tj = -7°C
2.94
2.23
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
12.09 kW
11.82 kW
COP Tj = +2°C
3.77
3.23
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
14.00 kW
13.86 kW
COP Tj = +7°C
4.76
4.42
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
15.54 kW
15.62 kW
COP Tj = 12°C
4.74
4.89
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
7.33 kW
7.10 kW
COP Tj = Tbiv
2.33
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.92 kW
5.99 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.89
1.36
WTOL
58 °C
58 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
8.99 kW
8.71 kW
Annual energy consumption Qhe
6750 kWh
7989 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.33
7.10
COP Tj = -15°C (if TOL<-20°C)
2.33
1.65
Cdh Tj = -15 °C
1.00
1.00