Certificate holders

Subtype

F1345-30

Certificate Holder
Nibe AB
Box 14
S-28521 Markaryd
Sweden
Registration number
012-051
Certification Body
RISE CERT
Subtype title
F1345-30
Driving energy
n/a
Heat Pump Type
Brine/Water
Refrigerant
R407c
Mass of Refrigerant

4,000 kg

Certification Date
n/a
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

F1345-30
Configure model
Model name
F1345-30
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

30.72 kW

29.40 kW

El input

6.92 kW

10.20 kW

COP

4.44

2.90

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

144 %

Prated

35.00 kW

35.00 kW

SCOP

4.85

3.80

Tbiv

-18 °C

-16 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

31.00 kW

30.10 kW

COP Tj = -7°C

4.75

3.55

Pdh Tj = +2°C

15.60 kW

15.30 kW

COP Tj = +2°C

5.06

4.04

Pdh Tj = +7°C

15.60 kW

15.40 kW

COP Tj = +7°C

5.14

4.39

Pdh Tj = 12°C

15.60 kW

15.50 kW

COP Tj = 12°C

4.86

4.55

Pdh Tj = Tbiv

30.80 kW

29.60 kW

COP Tj = Tbiv

4.55

3.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

30.80 kW

19.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.38

2.99

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

60 W

60 W

PSB

7 W

7 W

PCK

70 W

70 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.20 kW

5.70 kW

Annual energy consumption Qhe

17817 kWh

22770 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

137 %

Prated

35.00 kW

35.00 kW

SCOP

4.65

3.63

Tbiv

-7 °C

-6 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

30.80 kW

29.50 kW

COP Tj = -7°C

4.51

3.15

Pdh Tj = +2°C

30.90 kW

30.20 kW

COP Tj = +2°C

4.69

3.64

Pdh Tj = +7°C

15.60 kW

15.30 kW

COP Tj = +7°C

5.02

4.09

Pdh Tj = 12°C

15.60 kW

15.40 kW

COP Tj = 12°C

5.01

4.40

Pdh Tj = Tbiv

30.80 kW

29.60 kW

COP Tj = Tbiv

4.51

3.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

30.80 kW

29.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.38

2.99

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

80 W

80 W

PSB

7 W

7 W

PCK

70 W

70 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.20 kW

5.70 kW

Annual energy consumption Qhe

15539 kWh

19880 kWh