Certificate holders

Subtype

WWC 190 H/X

Certificate Holder
ait-deutschland GmbH
Industriestr. 3
95359 Kasendorf
Germany
Registration number
041-K001-34 / 1
Certification Body
BRE Global Limited
Subtype title
WWC 190 H/X
Driving energy
n/a
Heat Pump Type
Water/Water
Refrigerant
R407c
Mass of Refrigerant

4,300 kg

Certification Date
06.09.2019
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

WWC 190H/X
Configure model
Model name
WWC 190H/X
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

18.60 kW

16.30 kW

El input

3.27 kW

4.81 kW

COP

5.60

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

234 %

179 %

Prated

18.30 kW

16.30 kW

SCOP

6.05

4.68

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

18.34 kW

16.60 kW

COP Tj = -7°C

5.66

3.63

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

18.56 kW

17.60 kW

COP Tj = +2°C

6.03

4.61

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

18.76 kW

18.20 kW

COP Tj = +7°C

6.39

5.40

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

18.96 kW

18.80 kW

COP Tj = 12°C

6.72

6.37

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

18.30 kW

16.30 kW

COP Tj = Tbiv

5.60

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

18.30 kW

16.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.60

3.39

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6249 kWh

7193 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

236 %

181 %

Prated

18.30 kW

16.30 kW

SCOP

6.09

4.73

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

18.30 kW

16.30 kW

COP Tj = +2°C

5.60

3.39

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

18.52 kW

17.20 kW

COP Tj = +7°C

5.95

4.18

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

18.82 kW

18.40 kW

COP Tj = 12°C

6.51

5.71

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

18.30 kW

16.30 kW

COP Tj = Tbiv

5.60

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

18.30 kW

16.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.60

3.39

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4012 kWh

4604 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

241 %

186 %

Prated

18.30 kW

16.30 kW

SCOP

6.22

4.86

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

18.59 kW

17.40 kW

COP Tj = -7°C

6.09

4.39

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

18.77 kW

18.10 kW

COP Tj = +2°C

6.41

5.26

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

18.90 kW

18.60 kW

COP Tj = +7°C

6.65

6.04

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

18.94 kW

19.00 kW

COP Tj = 12°C

6.59

6.70

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

18.30 kW

16.30 kW

COP Tj = Tbiv

5.60

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

18.30 kW

16.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.60

3.39

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

7258 kWh

8276 kWh

Pdh Tj = -15°C (if TOL<-20°C)

0.01

0.01

COP Tj = -15°C (if TOL<-20°C)

0.01

0.01

Cdh Tj = -15 °C

1.00

1.00