Certificate holders

Subtype

WWC 130 H/X

Certificate Holder
ait-deutschland GmbH
Industriestr. 3
95359 Kasendorf
Germany
Registration number
041-K001-32 / 1
Certification Body
BRE Global Limited
Subtype title
WWC 130 H/X
Driving energy
n/a
Heat Pump Type
Water/Water
Refrigerant
R407c
Mass of Refrigerant

3,500 kg

Certification Date
06.09.2019
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

WWC 130H/X
Configure model
Model name
WWC 130H/X
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.90 kW

11.70 kW

El input

2.35 kW

3.43 kW

COP

5.50

3.23

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

176 %

Prated

12.90 kW

11.70 kW

SCOP

5.88

4.60

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.92 kW

11.88 kW

COP Tj = -7°C

5.55

3.63

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

13.06 kW

12.48 kW

COP Tj = +2°C

5.89

4.56

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

13.18 kW

12.84 kW

COP Tj = +7°C

6.22

5.29

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

13.30 kW

13.20 kW

COP Tj = 12°C

6.49

6.16

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

12.90 kW

11.70 kW

COP Tj = Tbiv

5.49

3.41

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.90 kW

11.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.49

3.41

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4535 kWh

5250 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

228 %

177 %

Prated

12.90 kW

11.70 kW

SCOP

5.90

4.63

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.90 kW

11.70 kW

COP Tj = +2°C

5.49

3.41

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

13.03 kW

12.24 kW

COP Tj = +7°C

5.82

4.15

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

13.22 kW

12.96 kW

COP Tj = 12°C

6.33

5.57

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

12.90 kW

11.70 kW

COP Tj = Tbiv

5.49

3.41

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.90 kW

11.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.49

3.41

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2920 kWh

3373 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

233 %

183 %

Prated

12.90 kW

11.70 kW

SCOP

6.04

4.77

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

13.08 kW

12.36 kW

COP Tj = -7°C

5.95

4.35

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

13.08 kW

12.78 kW

COP Tj = +2°C

6.24

5.16

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

13.26 kW

13.08 kW

COP Tj = +7°C

6.45

5.88

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

13.28 kW

13.32 kW

COP Tj = 12°C

6.35

6.43

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

12.90 kW

11.70 kW

COP Tj = Tbiv

5.49

3.41

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.90 kW

11.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.49

3.41

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5269 kWh

6049 kWh

Pdh Tj = -15°C (if TOL<-20°C)

0.01

0.01

COP Tj = -15°C (if TOL<-20°C)

0.01

0.01

Cdh Tj = -15 °C

1.00

1.00