1,500 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
6.10 kW
4.56 kW
El input
1.35 kW
1.50 kW
COP
4.52
3.04
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
141 %
Prated
7.00 kW
6.00 kW
SCOP
4.95
3.73
Tbiv
-18 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.40 kW
5.20 kW
COP Tj = -7°C
4.96
3.58
Pdh Tj = +2°C
6.50 kW
5.60 kW
COP Tj = +2°C
5.10
3.96
Pdh Tj = +7°C
6.60 kW
5.90 kW
COP Tj = +7°C
5.18
4.25
Pdh Tj = 12°C
6.60 kW
6.10 kW
COP Tj = 12°C
4.97
4.33
Pdh Tj = Tbiv
6.20 kW
4.90 kW
COP Tj = Tbiv
4.75
3.32
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.10 kW
4.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.59
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
12 W
10 W
PSB
7 W
7 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.90 kW
1.50 kW
Annual energy consumption Qhe
3487 kWh
3969 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
137 %
Prated
7.00 kW
6.00 kW
SCOP
4.80
3.63
Tbiv
-7 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.20 kW
4.80 kW
COP Tj = -7°C
4.71
3.18
Pdh Tj = +2°C
6.30 kW
5.30 kW
COP Tj = +2°C
4.91
3.69
Pdh Tj = +7°C
6.50 kW
5.60 kW
COP Tj = +7°C
5.09
4.02
Pdh Tj = 12°C
6.70 kW
6.00 kW
COP Tj = 12°C
5.14
4.29
Pdh Tj = Tbiv
6.20 kW
4.90 kW
COP Tj = Tbiv
4.71
3.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.10 kW
4.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.59
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
65 °C
65 °C
Poff
1 W
2 W
PTO
12 W
10 W
PSB
7 W
7 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.90 kW
1.50 kW
Annual energy consumption Qhe
3010 kWh
3425 kWh
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
6.10 kW
4.56 kW
El input
1.35 kW
1.50 kW
COP
4.52
3.04
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
141 %
Prated
7.00 kW
6.00 kW
SCOP
4.95
3.73
Tbiv
-18 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.40 kW
5.20 kW
COP Tj = -7°C
4.96
3.58
Pdh Tj = +2°C
6.50 kW
5.60 kW
COP Tj = +2°C
5.10
3.96
Pdh Tj = +7°C
6.60 kW
5.90 kW
COP Tj = +7°C
5.18
4.25
Pdh Tj = 12°C
6.60 kW
6.10 kW
COP Tj = 12°C
4.97
4.33
Pdh Tj = Tbiv
6.20 kW
4.90 kW
COP Tj = Tbiv
4.75
3.32
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.10 kW
4.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.59
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
12 W
10 W
PSB
7 W
7 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.90 kW
1.50 kW
Annual energy consumption Qhe
3487 kWh
3969 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
137 %
Prated
7.00 kW
6.00 kW
SCOP
4.80
3.63
Tbiv
-7 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.20 kW
4.80 kW
COP Tj = -7°C
4.71
3.18
Pdh Tj = +2°C
6.30 kW
5.30 kW
COP Tj = +2°C
4.91
3.69
Pdh Tj = +7°C
6.50 kW
5.60 kW
COP Tj = +7°C
5.09
4.02
Pdh Tj = 12°C
6.70 kW
6.00 kW
COP Tj = 12°C
5.14
4.29
Pdh Tj = Tbiv
6.20 kW
4.90 kW
COP Tj = Tbiv
4.71
3.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.10 kW
4.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.59
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
65 °C
65 °C
Poff
1 W
2 W
PTO
12 W
10 W
PSB
7 W
7 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.90 kW
1.50 kW
Annual energy consumption Qhe
3010 kWh
3425 kWh
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
6.10 kW
4.56 kW
El input
1.35 kW
1.50 kW
COP
4.52
3.04
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
141 %
Prated
7.00 kW
6.00 kW
SCOP
4.95
3.73
Tbiv
-18 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.40 kW
5.20 kW
COP Tj = -7°C
4.96
3.58
Pdh Tj = +2°C
6.50 kW
5.60 kW
COP Tj = +2°C
5.10
3.96
Pdh Tj = +7°C
6.60 kW
5.90 kW
COP Tj = +7°C
5.18
4.25
Pdh Tj = 12°C
6.60 kW
6.10 kW
COP Tj = 12°C
4.97
4.33
Pdh Tj = Tbiv
6.20 kW
4.90 kW
COP Tj = Tbiv
4.75
3.32
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.10 kW
4.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.59
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
12 W
10 W
PSB
7 W
7 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.90 kW
1.50 kW
Annual energy consumption Qhe
3487 kWh
3969 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
137 %
Prated
7.00 kW
6.00 kW
SCOP
4.80
3.63
Tbiv
-7 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.20 kW
4.80 kW
COP Tj = -7°C
4.71
3.18
Pdh Tj = +2°C
6.30 kW
5.30 kW
COP Tj = +2°C
4.91
3.69
Pdh Tj = +7°C
6.50 kW
5.60 kW
COP Tj = +7°C
5.09
4.02
Pdh Tj = 12°C
6.70 kW
6.00 kW
COP Tj = 12°C
5.14
4.29
Pdh Tj = Tbiv
6.20 kW
4.90 kW
COP Tj = Tbiv
4.71
3.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.10 kW
4.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.59
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
65 °C
65 °C
Poff
1 W
2 W
PTO
12 W
10 W
PSB
7 W
7 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.90 kW
1.50 kW
Annual energy consumption Qhe
3010 kWh
3425 kWh
Domestic Hot Water (DHW)
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
98 %
COP
2.45
Heating up time
2:45 h:min
Standby power input
55.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
240 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
98 %
COP
2.45
Heating up time
2:45 h:min
Standby power input
55.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
240 l
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
6.10 kW
4.56 kW
El input
1.35 kW
1.50 kW
COP
4.52
3.04
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
141 %
Prated
7.00 kW
6.00 kW
SCOP
4.95
3.73
Tbiv
-18 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.40 kW
5.20 kW
COP Tj = -7°C
4.96
3.58
Pdh Tj = +2°C
6.50 kW
5.60 kW
COP Tj = +2°C
5.10
3.96
Pdh Tj = +7°C
6.60 kW
5.90 kW
COP Tj = +7°C
5.18
4.25
Pdh Tj = 12°C
6.60 kW
6.10 kW
COP Tj = 12°C
4.97
4.33
Pdh Tj = Tbiv
6.20 kW
4.90 kW
COP Tj = Tbiv
4.75
3.32
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.10 kW
4.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.59
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
12 W
10 W
PSB
7 W
7 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.90 kW
1.50 kW
Annual energy consumption Qhe
3487 kWh
3969 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
137 %
Prated
7.00 kW
6.00 kW
SCOP
4.80
3.63
Tbiv
-7 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.20 kW
4.80 kW
COP Tj = -7°C
4.71
3.18
Pdh Tj = +2°C
6.30 kW
5.30 kW
COP Tj = +2°C
4.91
3.69
Pdh Tj = +7°C
6.50 kW
5.60 kW
COP Tj = +7°C
5.09
4.02
Pdh Tj = 12°C
6.70 kW
6.00 kW
COP Tj = 12°C
5.14
4.29
Pdh Tj = Tbiv
6.20 kW
4.90 kW
COP Tj = Tbiv
4.71
3.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.10 kW
4.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.59
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
65 °C
65 °C
Poff
1 W
2 W
PTO
12 W
10 W
PSB
7 W
7 W
PCK
14 W
14 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.90 kW
1.50 kW
Annual energy consumption Qhe
3010 kWh
3425 kWh
Domestic Hot Water (DHW)
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
98 %
COP
2.45
Heating up time
2:45 h:min
Standby power input
55.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
240 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
98 %
COP
2.45
Heating up time
2:45 h:min
Standby power input
55.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
240 l